The Effect of Increasing Thread Depth on the Initial Stability of Dental Implants: An In Vitro Study

被引:1
|
作者
Cucinelli, Chiara [1 ]
Pereira, Miguel Silva [1 ,2 ]
Borges, Tiago [1 ,2 ]
Figueiredo, Rui [3 ,4 ]
Leitao-Almeida, Bruno [1 ,2 ]
机构
[1] Univ Catolica Portuguesa, Fac Dent, P-3510 Viseu, Portugal
[2] Univ Catolica Portuguesa, Ctr Interdisciplinary Res Hlth CIIS, P-3510 Viseu, Portugal
[3] Univ Barcelona, Fac Med & Hlth Sci, Barcelona 08907, Spain
[4] Inst Invest Biomed Bellvitge IDIBELL, Barcelona 08908, Spain
来源
SURGERIES | 2024年 / 5卷 / 03期
关键词
dental implants; osseointegration; torque; resonance frequency analysis; RESONANCE FREQUENCY-ANALYSIS; INSERTION TORQUE; BONE-DENSITY; GEOMETRY; QUALITY;
D O I
10.3390/surgeries5030065
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The long-term success of dental implants largely depends on achieving primary stability, previously described as crucial to obtaining osseointegration and immediate loading protocol requirements. Implant thread depths seem to be one of the key factors influencing primary stability, particularly in low-density bone. Insertion torque (IT) and resonance frequency analysis (RFA) are considered the most reliable tests to assess primary stability. The aim of this work was to evaluate how different thread depths of commercially available dental implants affect primary stability in low-density D3 bone. Materials and Methods: An in vitro study was carried out between February 2024 and March 2024. Twenty-four dental implants were divided into four groups (six implants each) according to their thread depths (Group A: 4 mm, Group B: 4.5 mm, Group C: 5 mm, Group D: 5.5 mm) and were inserted in D3-type artificial bone blocks. The main outcome variables were the IT and the Implant Stability Quotient (ISQ) measured in four different areas of the implant (buccal, lingual, mesial, and distal) with an Osstel (R) ISQ reader. Descriptive and inferential analyses of the data were performed, and the significance value was set at 5%. Results: A total of 24 implants were analyzed. The highest IT values were obtained in Group D, with a mean of 54.03 Ncm (standard deviation (SD) = 8.99), while the lowest measurements were observed in Group A (mean = 25.12; SD: 2.96 N.cm). The mean ISQ values were consistently higher in Group D for each analyzed area, with a mean of 70.13 N.cm (SD = 1.12). Conclusions: Taking into consideration the limitations of this in vitro study, greater thread depths seem to increase the primary stability of dental implants placed in soft bone. Furthermore, a positive correlation was observed between all IT and ISQ values, regardless of the thread depth.
引用
收藏
页码:817 / 825
页数:9
相关论文
共 50 条
  • [1] The Effect of Number and Distribution of Mini Dental Implants on Overdenture Stability: An In Vitro Study
    Alshenaiber, Rafif
    Barclay, Craig
    Silikas, Nick
    MATERIALS, 2022, 15 (09)
  • [2] Initial Stability Study of Calcium Phosphate Coated Dental Implants
    Changkook YOU
    In-sung YEO
    Tae-kwan EOM
    M W AHN
    Sukyoung KIM
    Journal of Wuhan University of Technology-Materials Science, 2005, (S1) : 246 - 248
  • [3] The Effect of V-Thread and Square Thread Dental Implants on Bone
    AL-Sanea, Abdulrahman
    Mutlu, Ibrahim
    Kisioglu, Yasin
    Mohamed, Eltahir
    JOURNAL OF BIOMIMETICS BIOMATERIALS AND BIOMEDICAL ENGINEERING, 2023, 60 : 83 - 96
  • [4] The effect of the thread depth on the mechanical properties of the dental implant
    Lee, Sun-Young
    Kim, Sung-Jun
    An, Hyun-Wook
    Kim, Hyun-Seung
    Ha, Dong-Guk
    Ryo, Kyung-Ho
    Park, Kwang-Bum
    JOURNAL OF ADVANCED PROSTHODONTICS, 2015, 7 (02): : 115 - 121
  • [5] Primary stability of narrow-diameter dental implants with a multiple condensing thread design placed in bone with and without osteotomes: An in vitro study
    Romanos, Georgios E.
    Lau, Jessica
    Delgado-Ruiz, Rafael
    Javed, Fawad
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (03) : 409 - 414
  • [6] Insertion Speed Affects the Initial Stability of Dental Implants
    Hsu, Yuan-Yang
    Tsai, Ming-Tzu
    Huang, Heng-Li
    Fuh, Lih-Jyh
    Hsu, Jui-Ting
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2022, 42 (04) : 516 - 525
  • [7] Insertion Speed Affects the Initial Stability of Dental Implants
    Yuan-Yang Hsu
    Ming-Tzu Tsai
    Heng-Li Huang
    Lih-Jyh Fuh
    Jui-Ting Hsu
    Journal of Medical and Biological Engineering, 2022, 42 : 516 - 525
  • [8] The Five Thread Guideline: A New Guideline for Predicting Primary Stability With Dental Implants
    Stanley, Robert
    JOURNAL OF ORAL IMPLANTOLOGY, 2020, 46 (01) : 81 - 86
  • [9] Effect of thread dimensions of functionally graded dental implants on stress distribution
    Celik, Nevin
    Kaman, Mete Onur
    CURRENT OPINION IN BIOTECHNOLOGY, 2013, 24 : S46 - S46
  • [10] Effect of Tribocorrosion on Mechanical Behavior of Titanium Dental Implants: An In Vitro Study
    Vegas-Bustamante, Erika
    Sanmarti-Garcia, Gemma
    Gil, Javier
    Delgado-Garona, Luis
    Figueiredo, Rui
    Camps-Font, Octavi
    Sanchez-Garces, M. angeles
    Toledano-Serrabona, Jorge
    MATERIALS, 2025, 18 (05)