An Ultrasensitive QCM Humidity Sensor Based on GO/OH-GQDs

被引:0
|
作者
Ding, Xing [1 ]
Li, Jing [1 ]
Hu, Wei [1 ]
Chen, Xiangdong [1 ]
Xia, Wenhe [2 ]
机构
[1] Southwest Jiaotong Univ, Sch Informat Sci & Technol, Chengdu 611756, Peoples R China
[2] Southwest Petr Univ, Sch Elect Engn & Informat, Chengdu 610500, Sichuan, Peoples R China
关键词
Sensors; Humidity; Sensitivity; Sensor phenomena and characterization; Surface impedance; Surface treatment; Scanning electron microscopy; Graphene oxide (GO); high sensitivity; hydroxylated graphene quantum dots (OH-GQDs); quartz crystal microbalance (QCM) humidity sensor; CARBON NANOTUBES;
D O I
10.1109/JSEN.2024.3432606
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Sensitivity is one of the most important characteristics of quartz crystal microbalance (QCM) humidity sensors, and the methods to improve the sensitivity have always been the research focus in the field of QCM humidity sensors. This study proposes an ultrasensitive (179.88 Hz/%RH) QCM humidity sensor using graphene oxide (GO) and hydroxylated graphene quantum dots (OH-GQDs) as the sensitive materials. The experimental results show that the incorporation of OH-GQDs significantly increases the number of active sites on the GO, and the GO/OH-GQDs composite has a larger specific surface area, which greatly increases the water absorption capacity. In addition, the sensor has a low humidity hysteresis (1.3%), fast response and recovery times (7/10 s), good stability, and good repeatability. This sensor's ultrahigh sensitivity suggests significant potential for advancing the development of high-performance QCM humidity sensors.
引用
收藏
页码:27191 / 27197
页数:7
相关论文
共 50 条
  • [1] GO/CNT-OH/Nafion Nanocomposite Humidity Sensor Based on the LC Wireless Method
    Wang, Chengkai
    Jiao, Chunxiao
    Wang, Meng
    Pan, Jinghong
    Wang, Qi
    NANOMATERIALS, 2023, 13 (13)
  • [2] A QCM Humidity Sensors Based on GO/Nafion Composite Films With Enhanced Sensitivity
    Chen, Xinpeng
    Chen, Xiangdong
    Li, Ning
    Ding, Xing
    Zhao, Xuan
    IEEE SENSORS JOURNAL, 2016, 16 (24) : 8874 - 8883
  • [3] Humidity Sensor Based on In(OH)3 Nanoparticles
    Zhao, Zhihua
    Meng, Xianghao
    Pan, Yafang
    Jin, Guixin
    Shen, Xiaoqing
    Wu, Lan
    ACS APPLIED NANO MATERIALS, 2024, 7 (14) : 16498 - 16505
  • [4] Comparative Study of Gravimetric Humidity Sensor Platforms Based on CMUT and QCM
    Zheng, Zhou
    Zhang, Guodong
    Wang, Xiaomin
    Kong, Xu
    MICROMACHINES, 2022, 13 (10)
  • [5] PEDOT: PSS/QCM-based multimodal humidity and pressure sensor
    Muckley, Eric S.
    Lynch, James
    Kumar, Rajeev
    Sumpter, Bobby
    Ivanov, Ilia N.
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 236 : 91 - 98
  • [6] Novel highly sensitive QCM humidity sensor with low hysteresis based on graphene oxide (GO)/poly(ethyleneimine) layered film
    Yuan, Zhen
    Tai, Huiling
    Ye, Zongbiao
    Liu, Chunhua
    Xie, Guangzhong
    Du, Xiaosong
    Jiang, Yadong
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 234 : 145 - 154
  • [7] Relative humidity sensor based on hollow core fiber filled with GQDs-PVA
    Zhao, Yong
    Tong, Rui-jie
    Chen, Mao-Qing
    Xia, Feng
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 284 : 96 - 102
  • [8] An ultrasensitive electrochemiluminescence sensor for the detection of HULC based on Au@Ag/GQDs as a signal indicator
    Li, Jing-Jing
    Shang, Lei
    Jia, Li-Ping
    Ma, Rong-Na
    Zhang, Wei
    Jia, Wen-Li
    Wang, Huai-Sheng
    Xu, Ke-Hua
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 824 : 114 - 120
  • [9] Quartz Crystal Microbalance (QCM) used as humidity sensor
    Pascal-Delannoy, F
    Sorli, B
    Boyer, A
    SENSORS AND ACTUATORS A-PHYSICAL, 2000, 84 (03) : 285 - 291
  • [10] A QCM humidity sensor based on fullerene/graphene oxide nanocomposites with high quality factor
    Ding, Xing
    Chen, Xiangdong
    Chen, Xinpeng
    Zhao, Xuan
    Li, Ning
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 266 : 534 - 542