Novel disposable screen-printed sensors based on copper oxide nanoparticles for sensitive voltammetric assay of antazoline

被引:0
|
作者
Snari, Razan M. [1 ]
Alessa, Hussain [1 ]
Alessa, Ali H. [2 ]
Alanazi, Kaseb D. [3 ]
Mogharbel, Roaa T. [4 ]
Al-Ahmed, Zehbah A. [5 ]
Shah, Reem [1 ]
El-Metwaly, Nashwa M. [1 ,6 ]
机构
[1] Umm Al Qura Univ, Fac Sci, Dept Chem, Mecca, Saudi Arabia
[2] Univ Tabuk, Fac Sci, Dept Chem, Tabuk, Saudi Arabia
[3] Univ Hail, Coll Sci, Dept Chem, Hail 81442, Saudi Arabia
[4] Northern Border Univ, Fac Sci, Dept Chem, Ar Ar 73222, Saudi Arabia
[5] King Khalid Univ, Appl Coll Dhahran Aljanoub, Abha, Saudi Arabia
[6] Mansoura Univ, Fac Sci, Dept Chem, Mansoura, Egypt
关键词
Antazoline disposable voltammetric sensor; Copper oxide nanopowder; Differential pulse voltammetry; Degradation studies; Ophthalmic solutions and biological samples; ELECTROCHEMICAL-BEHAVIOR; NAPHAZOLINE; HYDROCHLORIDE; NANOMATERIALS; DEGRADATION; ELECTRODE; PLASMA; ACID;
D O I
10.1016/j.microc.2024.110702
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The fabrication and electroanalytical validation of a novel homemade screen-printed carbon electrode enriched with copper oxide nanoparticles (CuONPs/SPCEs) were demonstrated for sensitive and selective voltammetric determination antazoline (ANT) in eye drop solution and spiked serum samples. With a reported electrocatalytic activity, CuONPs catalyzed the oxidation of ANT at the electrode surface showing an irreversible anodic oxidation peak at 0.9 V under a diffusion-controlled electrode reaction. Based on the electroanalytical and molecular orbital calculation studies, oxidation of ANT molecule undergoes via oxidation of the aliphatic nitrogen atom within the ANT moiety. Linear calibration curves were illustrated covering the ANT concentration ranged from 0.01 to 3.819 mu g mL- 1 with and limit of detection 3 ng mL-1.- 1 . The fabricated sensors enriched with CuONPs exhibited high fabrication and measurement reproducibility with a prolonged shelf lifetime (6 months). The electroanalytical approach presented adequate sensitivity and selectivity with a short analysis time, applying low-cost instrumentation and simple pretreatment protocol avoiding handling hazardous organic solvents. Trace ANT was monitored in the presence of different interfering species, degradation products, and xylometazoline hydrochloride (ZYL) in the co-formulated ophthalmic pharmaceutical samples. The CuONPs based voltammetric sensors were introduced as a reliable eco-friendly analytical tool for monitoring ANT in ophthalmic solutions and biological fluids with acceptable recovery values.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Copper Oxide Based Disposable Sensors for Sensitive Voltammetric Assay of Sumatriptan
    Aldawsari, Afrah M.
    Khalifa, Mohamed E.
    Munshi, Alaa M.
    Shah, Reem
    Keshk, Ali A.
    Saad, Fawaz
    El-Metwaly, Nashwa M.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (05): : 1 - 13
  • [2] As(III) voltammetric detection by means of disposable screen-printed gold electrochemical sensors
    Laschi, S.
    Bagni, G.
    Palchetti, I.
    Mascini, M.
    ANALYTICAL LETTERS, 2007, 40 (16-18) : 3002 - 3013
  • [3] Highly sensitive and disposable screen-printed ionic liquid/graphene based electrochemical sensors
    Kamsong, Wichayaporn
    Primpray, Vitsarut
    Pasakon, Patiya
    Sriprachuabwong, Chakrit
    Pakapongpan, Saithip
    Mensing, Johannes Philipp
    Wisitsoraat, Anurat
    Tuantranont, Adisorn
    Karuwan, Chanpen
    Electrochemistry Communications, 2022, 135
  • [4] Highly sensitive and disposable screen-printed ionic liquid/graphene based electrochemical sensors
    Kamsong, Wichayaporn
    Primpray, Vitsarut
    Pasakon, Patiya
    Sriprachuabwong, Chakrit
    Pakapongpan, Saithip
    Mensing, Johannes Philipp
    Wisitsoraat, Anurat
    Tuantranont, Adisorn
    Karuwan, Chanpen
    ELECTROCHEMISTRY COMMUNICATIONS, 2022, 135
  • [5] Disposable Screen-Printed Microchip Based on Nanoparticles Sensitive Membrane for Potentiometric Determination of Lead
    Alrobaian, Majed
    Alfadhel, Munerah
    Zayed, Sayed
    Aldosari, Mohammad
    Arida, Hassan
    JOURNAL OF SENSORS, 2024, 2024
  • [6] Zirconium Oxide Nanostructure Integrated Screen-Printed Mirabegron Voltammetric Sensors
    Snari, Razan M.
    Alharbi, Arwa
    Munshi, Alaa M.
    Al-Ahmed, Zehbah A.
    Aljuhani, Enas
    Alluhaybi, Ahmad A.
    Althagafi, Ismail
    El-Metwaly, Nashwa M.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2023, 170 (11)
  • [7] Voltammetric determination of Rutin at Screen-Printed carbon disposable electrodes
    de Oliveira-Roberth, Aline
    Santos, Diego I. V.
    Cordeiro, Diogo D.
    Lino, Fernando M. de A.
    Bara, Maria T. F.
    Gil, Eric de S.
    CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2012, 10 (05): : 1609 - 1616
  • [8] Voltammetric Determination of Neonicotinoid Pesticides at Disposable Screen-Printed Sensors Featuring a Sputtered Bismuth Electrode
    Lezi, Nikolitsa
    Economou, Anastasios
    ELECTROANALYSIS, 2015, 27 (10) : 2313 - 2321
  • [9] Disposable screen-printed sensors for determination of duloxetine hydrochloride
    Nawal A Alarfaj
    Reda A Ammar
    Maha F El-Tohamy
    Chemistry Central Journal, 6
  • [10] Screen-Printed Disposable Sensors Modified with Bismuth Precursors for Rapid Voltammetric Determination of 3 Ecotoxic Nitrophenols
    Lezi, Nikolitsa
    Economou, Anastasios
    Barek, Jiri
    Prodromidis, Mamas
    ELECTROANALYSIS, 2014, 26 (04) : 766 - 775