A fast evaluation method for surface area, volume fraction, and hydraulic diameter of TPMS with different geometric characteristics

被引:0
|
作者
He, Xinyu [1 ]
Yang, Ce [1 ]
Zheng, Mingqiu [1 ]
Zhang, Hanzhi [1 ]
Du, Yadong [1 ,2 ]
机构
[1] Beijing Inst Technol, Sch Mech Engn, 5 Zhong Guan Cun South RD, Beijing 100081, Peoples R China
[2] Natl Univ Singapore, Dept Mech Engn, Singapore, Singapore
基金
中国国家自然科学基金;
关键词
Triply periodic minimal surface; numerical design method; regression fitting equation; geometry characteristics; parallelogram surface patch method; triangular surface patch method; ENERGY-ABSORPTION; OPTIMIZATION; SCAFFOLDS;
D O I
10.1177/09544062241277342
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The utilization of triply periodic minimal surface (TPMS) structures, fabricated through additive manufacturing techniques, in engineering applications has garnered considerable attention. However, existing studies have largely overlooked the intricate relationship between design parameters and key geometric indices such as surface area, volume fraction, and hydraulic diameters, along with their distribution patterns. This study aims to fill this gap by conducting a comprehensive investigation to unveil the correlations between design parameters and performance indices for various TPMS types. A newly developed parallelogram patch method for area calculation is introduced and compared with the conventional triangular patch method. Regression equations are synthesized to derive geometric indices based on design parameters, facilitating the final performance prediction. Notably, Fischer Koch S, Schoen I-WP, and Schwarz Primitive emerge as the leading performers, achieving the largest surface area of 21.523 m2, volume fraction of 0.8732, and hydraulic diameter of 0.7856 m, respectively, within the feasible range. Conversely, Schoen Gyroid, Schwarz Primitive, and Fischer Koch S exhibit the lowest surface area of 3.5668 m2, volume fraction of 0.0752, and hydraulic diameter of 0.0745 m. The regression equations and the parallelogram patch area calculating method, demonstrate commendable accuracy, with less than a 2.5% relative error, making them suitable for practical calculations. These summarized regression equations can serve as a valuable guide for the preliminary design of TPMS lattices.
引用
收藏
页码:3 / 18
页数:16
相关论文
共 14 条
  • [1] Modeling of volume and surface area of apple from their geometric characteristics and artificial neural network
    Ziaratban, Armin
    Azadbakht, Mohsen
    Ghasemnezhad, Azim
    INTERNATIONAL JOURNAL OF FOOD PROPERTIES, 2017, 20 (04) : 762 - 768
  • [2] Effects of Forward and Reverse Shear Displacements on Geometric and Hydraulic Characteristics of Single Rough Fracture by the Finite Volume Method
    Niu, YuLong
    Wang, Yuan
    Li, Jinghua
    Sun, Zhiyu
    Xiang, Xin
    Wang, Zhikui
    Zhao, Xiaoming
    LITHOSPHERE, 2022, 2022 (SpecialIssue3)
  • [3] A method of measuring the specific surface area of bentonite for evaluation of the hydraulic performance of bentonite engineered barriers
    Kobayashi, I.
    Owada, H.
    Ishii, T.
    Iizuka, A.
    Geomechanics from Micro to Macro, Vols I and II, 2015, : 1285 - 1290
  • [4] Evaluation of Thermal Hydraulic Characteristics of a Two Phase Superhydrophobic Microfluidic Device using Volume of Fluid Method
    Aziz, Umair
    Nadeem, Muhammad
    Xin, Feng
    Kilic, Mustafa
    Ullah, Atta
    NANOSCALE AND MICROSCALE THERMOPHYSICAL ENGINEERING, 2022, 26 (01) : 67 - 82
  • [5] COMPARISON OF EJECTION FRACTION CALCULATED BY 9 DIFFERENT VOLUME CALCULATION METHODS (DESCRIPTION AND EVALUATION OF A NEW METHOD)
    BERANEK, I
    MOORE, R
    KIM, S
    FORMANEK, A
    AMPLATZ, K
    RADIOLOGY, 1976, 120 (03) : 553 - 556
  • [6] THE CAPTIVE BUBBLE METHOD FOR THE EVALUATION OF PULMONARY SURFACTANT - SURFACE-TENSION, AREA, AND VOLUME CALCULATIONS
    SCHOEL, WM
    SCHURCH, S
    GOERKE, J
    BIOCHIMICA ET BIOPHYSICA ACTA-GENERAL SUBJECTS, 1994, 1200 (03): : 281 - 290
  • [7] A method for the determination of accessible surface area, pore volume, pore size and its volume distribution for homogeneous pores of different shapes
    D. D. Do
    L. F. Herrera
    D. Nicholson
    Adsorption, 2011, 17 : 325 - 335
  • [8] A method for the determination of accessible surface area, pore volume, pore size and its volume distribution for homogeneous pores of different shapes
    Do, D. D.
    Herrera, L. F.
    Nicholson, D.
    ADSORPTION-JOURNAL OF THE INTERNATIONAL ADSORPTION SOCIETY, 2011, 17 (02): : 325 - 335
  • [9] Effects of surface area to volume ratio of PLGA scaffolds with different architectures on scaffold degradation characteristics and drug release kinetics
    Chew, Sue Anne
    Arriaga, Marco A.
    Hinojosa, Victor A.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2016, 104 (05) : 1202 - 1211
  • [10] Preparation of high specific surface area nanoporous nickel oxide through fast precipitation method and studies on capacitor characteristics
    Cao, JM
    Zheng, MB
    Chen, YP
    Hou, HT
    He, JP
    Tao, J
    Li, HL
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 230 : U2076 - U2076