Evaluation of plate heat exchangers comprising sections with different chevron angle arrangements

被引:1
|
作者
dos Santos, F. J. [1 ]
Silva, R. P. P. [2 ]
de Paiva, K. V. [3 ]
Oliveira, J. L. G. [3 ]
机构
[1] PETROBRAS Petr Brasileiro SA, Ilha Fundao, Cidade Univ,Ave Horacio Macedo 950, Rio De Janeiro, RJ, Brazil
[2] Univ Alabama, Dept Mech Engn, Tuscaloosa, AL USA
[3] Univ Fed Santa Catarina, Dept Mobil Engn, Thermal Fluid Flow Grp T2F, Joinville, SC, Brazil
关键词
Gasketed Plate Heat Exchanger; Maldistribution; Mixed arrangements; Chevron; Friction factor; FLOW DISTRIBUTION; PRESSURE-DROP; REFRIGERANT MALDISTRIBUTION; THERMAL PERFORMANCE; EVAPORATORS; PART;
D O I
10.1016/j.applthermaleng.2024.123452
中图分类号
O414.1 [热力学];
学科分类号
摘要
Gasketed Plate Heat Exchangers (GPHEs) are essential equipment for thermal control of oil facilities owing to their compactness and well-organized assembly concept. In order to satisfy heat loads of several megawatts, numerous and large plates are necessary. The application of GPHEs with plentiful plates yields flow maldistribution which affects GPHE thermal-hydraulic performance. With the purpose of matching different heat loads and processing conditions or as an alternative to reduce maldistribution effects, GPHEs with mixed arrangements, comprising sections where channels contain different geometrical features, may be selected. This works addresses the evaluation of flow and pressure distributions in GPHEs with mixed arrangements. The pressure drop in each GPHE section is initially approximated by the pressure drop in parallel pipes, neglecting the pressure drop in the ports. With this assumption, the inlet flow rate is divided into two different parts. The pressure distributions in each section are assumed to maintain flow features of m2 2-model for U-type arrangement. The friction factor for each GPHE segment was determined with independent experiments including only one section type and with a small number of channels as to avoid flow maldistribution. Friction factor correlations were determined for single section GPHEs where each channel can be formed with plates containing different chevron angles: 30 degrees/30 degrees, degrees /30 degrees , 60 degrees/60 degrees, degrees /60 degrees , 66 degrees/66 degrees, degrees /66 degrees , 30 degrees/60 degrees degrees /60 degrees and 30 degrees/66 degrees, degrees /66 degrees , with channel Reynolds number ranging from 260 to 3,080. Subsequently, experiments with GPHEs containing mixed sections with high and low pressure drop channels were performed: 60 degrees/60 degrees degrees /60 degrees and 30 degrees/30 degrees, degrees /30 degrees , 30 degrees/30 degrees degrees /30 degrees and 66 degrees/66 degrees; degrees /66 degrees ; with total number of channels up to 180. The channel pressure drop was measured in regularly spaced locations. The pressure drop in each GPHE segment has been predicted with the fractional RMS deviation equal to 2.2%. Although the mass flow rate per channel has not been measured, it is expected that the predicted flow rate distribution can reasonably stand for the real one and, therefore, assisting in proper thermal performance evaluation.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Relationship between chevron angle and heat transfer performance of plate heat exchangers
    Zhu, Xiaowei
    CASE STUDIES IN THERMAL ENGINEERING, 2025, 69
  • [2] The characteristics of condensation in brazed plate heat exchangers with different chevron angles
    Han, DH
    Lee, KJ
    Kim, YH
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2003, 43 (01) : 66 - 73
  • [3] Performance Evaluation of Plate Heat Exchanger with Chevron Angle Variations
    Kwon, Oh-kyung
    Cha, Dong-an
    Yun, Jae-ho
    Kim, Hyo-sang
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2009, 33 (07) : 520 - 526
  • [4] Chevron Angle Effect on Plate and Shell Heat Exchangers Measured with Particle Tracking Velocimetry
    Beckedorff, Leonel
    Martins, Giovani S. M.
    de Paiva, Kleber, V
    Oliveira Jr, Amir A. M.
    Oliveira, Jorge L. G.
    HEAT TRANSFER ENGINEERING, 2022, 43 (22) : 1885 - 1899
  • [5] Effect of the Chevron Angle on Cooling Heat Transfer Characteristics of Supercritical Pressure Fluids in Plate Heat Exchangers
    Miyata, Kazushi
    Mori, Hideo
    Taniguchi, Takahiro
    Umezawa, Shuichi
    Sugita, Katsuhiko
    HEAT TRANSFER ENGINEERING, 2019, 40 (12) : 1007 - 1022
  • [6] Investigations on the performance of chevron type plate heat exchangers
    Oruganti Yaga Dutta
    B. Nageswara Rao
    Heat and Mass Transfer, 2018, 54 : 227 - 239
  • [7] Investigations on the performance of chevron type plate heat exchangers
    Dutta, Oruganti Yaga
    Rao, B. Nageswara
    HEAT AND MASS TRANSFER, 2018, 54 (01) : 227 - 239
  • [8] Relationship between inclination angle and friction factor of chevron-type plate heat exchangers
    Zhu, Xiaowei
    Haglind, Fredrik
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 162
  • [9] Effect of chevron angle on the thermofluids performance of shell-and-plate heat exchangers - A numerical approach
    Zhao, Yi
    Liu, Hai-yong
    Zhang, Li
    Wang, Chi-Chuan
    APPLIED THERMAL ENGINEERING, 2024, 239
  • [10] Numerical study on heat transfer and fluid dynamics in plate heat exchangers: Effects of chevron angle and aspect ratio
    Kaplan, Sami
    Bayramoglu, Kubilay
    Sarikanat, Mehmet
    Altay, Luetfiye
    JOURNAL OF THERMAL ENGINEERING, 2024, 10 (03): : 638 - 656