Racial Differences in Accuracy of Predictive Models for High-Flow Nasal Cannula Failure in COVID-19

被引:0
|
作者
Yang, Philip [1 ]
Gregory, Ismail A. [1 ]
Robichaux, Chad [2 ]
Holder, Andre L. [1 ]
Martin, Greg S. [1 ]
Esper, Annette M. [1 ]
Kamaleswaran, Rishikesan [2 ,3 ]
Gichoya, Judy W. [4 ]
Bhavani, Sivasubramanium V. [1 ]
机构
[1] Emory Univ, Div Pulm Allergy Crit Care & Sleep Med, Atlanta, GA 30322 USA
[2] Emory Univ, Sch Med, Dept Biomed Informat, Atlanta, GA USA
[3] Duke Univ, Sch Med, Dept Surg, Durham, NC USA
[4] Emory Univ, Sch Med, Dept Radiol & Imaging Sci, Atlanta, GA USA
基金
美国国家卫生研究院;
关键词
acute respiratory failure; COVID-19; high-flow nasal cannula; machine learning; HYPOXEMIC RESPIRATORY-FAILURE; PULSE OXIMETRY; OXYGEN-THERAPY; DATA QUALITY; VENTILATION; BIAS; CARE; RACE;
D O I
10.1097/CCE.0000000000001059
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
OBJECTIVES:To develop and validate machine learning (ML) models to predict high-flow nasal cannula (HFNC) failure in COVID-19, compare their performance to the respiratory rate-oxygenation (ROX) index, and evaluate model accuracy by self-reported race.DESIGN:Retrospective cohort study.SETTING:Four Emory University Hospitals in Atlanta, GA.PATIENTS:Adult patients hospitalized with COVID-19 between March 2020 and April 2022 who received HFNC therapy within 24 hours of ICU admission were included.INTERVENTIONS:None.MEASUREMENTS AND MAIN RESULTS:Four types of supervised ML models were developed for predicting HFNC failure (defined as intubation or death within 7 d of HFNC initiation), using routine clinical variables from the first 24 hours of ICU admission. Models were trained on the first 60% (n = 594) of admissions and validated on the latter 40% (n = 390) of admissions to simulate prospective implementation. Among 984 patients included, 317 patients (32.2%) developed HFNC failure. eXtreme Gradient Boosting (XGB) model had the highest area under the receiver-operator characteristic curve (AUROC) for predicting HFNC failure (0.707), and was the only model with significantly better performance than the ROX index (AUROC 0.616). XGB model had significantly worse performance in Black patients compared with White patients (AUROC 0.663 vs. 0.808, p = 0.02). Racial differences in the XGB model were reduced and no longer statistically significant when restricted to patients with nonmissing arterial blood gas data, and when XGB model was developed to predict mortality (rather than the composite outcome of failure, which could be influenced by biased clinical decisions for intubation).CONCLUSIONS:Our XGB model had better discrimination for predicting HFNC failure in COVID-19 than the ROX index, but had racial differences in accuracy of predictions. Further studies are needed to understand and mitigate potential sources of biases in clinical ML models and to improve their equitability.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] PREDICTORS OF HIGH-FLOW NASAL CANNULA FAILURE IN COVID-19
    Gregory, Ismail
    Bhavani, Sivasubramanium
    Yang, Philip
    Robichaux, Chad
    CRITICAL CARE MEDICINE, 2023, 51 (01) : 553 - 553
  • [2] High-Flow Nasal Cannula Therapy in Patients With COVID-19: Predictive Response Factors
    Raboni, Sonia M.
    Neves, Valeria C.
    Silva, Rauce M.
    Breda, Giovanni L.
    Ceregato, Andressa C. L.
    Broza, Thayza P.
    de Oliveira, Glauber
    Melo-Diaz, Lucelia L.
    Braga, Claudia B.
    Carraro, Cesar F.
    Arroyo, Natalia C.
    Bardy, Rafael F.
    Devetak, Gisele F.
    Ozawa, Caroline M.
    Graf, Maria Esther
    Dias, Vitor L.
    Ducroquet, Marcelo A.
    Nunes, Daniella P.
    Sokoloski, Caroline S.
    Petterle, Ricardo R.
    RESPIRATORY CARE, 2022, 67 (11) : 1443 - 1451
  • [3] Predicting Success of High-Flow Nasal Cannula in COVID-19
    Varipapa, Robert J., Jr.
    Sonti, Rajiv
    RESPIRATORY CARE, 2021, 66 (06) : 1044 - 1045
  • [4] High-Flow Nasal Cannula and COVID-19: A Clinical Review
    Crimi, Claudia
    Pierucci, Paola
    Renda, Teresa
    Pisani, Lara
    Carlucci, Annalisa
    RESPIRATORY CARE, 2022, 67 (02) : 227 - 240
  • [5] High-flow nasal cannula therapy for hypoxemic respiratory failure in patients with COVID-19
    Palacios Chavarria, Adrian
    Salinas Lezama, Erika
    Gonzalez Navarro, Mauricio
    Valdez Vazquez, Rafael Ricardo
    Herrera Bello, Hector
    Lomelin Gascon, Julieta
    Morales Juarez, Linda
    Arboleya Avendano, Monica
    Ramirez Gonzalez, Luis Esteban
    Ville Benavides, Rodrigo
    Alvarez Wyssmann, Renate Victoria
    Sandoval Ortiz, Brenda
    Rodriguez de la Cerda, Mariana Lizbeth
    Moreno Castaneda, Lidia
    Alberto Martinez-Juarez, Luis
    Gallardo-Rincon, Hector
    Tapia-Conyer, Roberto
    THERAPEUTIC ADVANCES IN INFECTIOUS DISEASE, 2021, 8
  • [6] Use of high-flow nasal cannula oxygen and risk factors for high-flow nasal cannula oxygen failure in critically-ill patients with COVID-19
    Zakaria Ait Hamou
    Nathan Levy
    Julien Charpentier
    Jean-Paul Mira
    Matthieu Jamme
    Mathieu Jozwiak
    Respiratory Research, 23
  • [7] Use of high-flow nasal cannula oxygen and risk factors for high-flow nasal cannula oxygen failure in critically-ill patients with COVID-19
    Hamou, Zakaria Ait
    Levy, Nathan
    Charpentier, Julien
    Mira, Jean-Paul
    Jamme, Matthieu
    Jozwiak, Mathieu
    RESPIRATORY RESEARCH, 2022, 23 (01)
  • [8] High-flow nasal cannula: COVID 19 and beyond
    Rali, Aniket Shitalkumar
    Garies, Taylor
    Narendra, Dharani
    Patel, Purvesh
    Guntupalli, Kalpalatha
    INDIAN JOURNAL OF RESPIRATORY CARE, 2020, 9 (02) : 134 - 140
  • [9] High-Flow Nasal Cannula in COVID-19 Pneumonia: Practical Issues
    Laserna, Andres
    Barahona-Correa, Julian E.
    Papadakos, Peter
    Esquinas, Antonio
    CRITICAL CARE MEDICINE, 2022, 50 (06) : E591 - E592
  • [10] 2023 Year in Review: High-Flow Nasal Cannula for COVID-19
    Davis, Michael D.