Diagnostic accuracy of the anion gap to identify toxic lithium concentrations: a single-center retrospective observational study

被引:0
|
作者
Honda, Hiroyuki [1 ]
Deuchi, Kazuki [2 ]
Fukasawa, Makusu [2 ]
Yamaguchi, Katsuichiro [2 ]
Nishiyama, Kei [2 ]
机构
[1] Niigata Univ, Med & Dent Hosp, Dept Crit Care Med, 754 Ichibancho,Chuo Ku, Niigata, Japan
[2] Niigata Univ, Med & Dent Hosp, Adv Emergency & Crit Care Ctr, Niigata, Japan
关键词
Anion gap; blood concentration; diagnostic characteristics; lithium; receiver operating curve; SCREENING TOOL; LIMITATIONS;
D O I
10.1080/15563650.2024.2380771
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
Introduction: Lithium exhibits a narrow margin between therapeutic doses and toxic blood concentrations, which can pose a substantial risk of toxic effects. Reportedly, lithium toxicity may be associated with a reduced anion gap; however, the precise relationship remains unclear. This study examined several different anion gap calculation methods to detect toxic lithium concentrations without directly measuring blood lithium concentrations. Methods: Our retrospective study analyzed blood samples collected for lithium concentration measurements. The anion gap was determined using three different methods, both with and without albumin and lactate concentration corrections. Samples were categorized into two groups based on lithium concentration (<1.5 or >= 1.5 mmol/L), and anion gap values were compared. Correlation and logistic regression analyses were used to assess the relationship between each anion gap indicator and lithium concentration. Receiver operating characteristic curves were used for diagnostic analysis. Results: Overall, 24 measurements were collected, with 41.7% of samples falling within the toxic range. The high-lithium concentration group exhibited significantly smaller anion gaps. Correlation and logistic regression analyses revealed a significant association between anion gap values and lithium concentrations. Areas under the receiver operating characteristic curve were: conventional anion gap 0.77 (95% CI: 0.55-0.94); albumin-corrected anion gap 0.85 (95% CI: 0.66-1.00); and both albumin- and lactate-corrected anion gap 0.86 (95% CI: 0.66-1.00). Discussion: The anion gap is calculated as the difference between measured cations and anions. Accumulation of lithium (a cation) may decrease measured cations and decrease the calculated anion gap. Abnormal albumin and lactate concentrations may also alter the anion gap and affect its usefulness as a diagnostic marker for elevated serum lithium concentrations. A negative likelihood ratio of 0.1 suggests that the anion gap might be valuable in excluding toxicity. Conclusions: The corrected anion gap, accounting for albumin and lactate concentrations, may be beneficial in suggesting the possibility of toxic lithium concentrations.
引用
收藏
页码:506 / 511
页数:6
相关论文
共 50 条
  • [1] Diagnostic Accuracy of Postmortem CT of Children: A Retrospective Single-Center Study
    Shelmerdine, Susan C.
    Davendralingam, Natasha
    Palm, Liina
    Minden, Tom
    Cary, Nat
    Sebire, Neil J.
    Arthurs, Owen J.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 212 (06) : 1335 - 1347
  • [2] Diagnostic yields and safety of thoracoscopic cryobiopsies in Japan: A single-center retrospective observational study
    Kamatani, Miwa
    Awano, Nobuyasu
    Inomata, Minoru
    Kuse, Naoyuki
    Sakamoto, Keita
    Kumasaka, Toshio
    Izumo, Takehiro
    RESPIROLOGY, 2024, 29 : 244 - 245
  • [3] Diagnostic yields and safety of thoracoscopic cryobiopsies in Japan: A single-center retrospective observational study
    Kamatani, Miwa
    Awano, Nobuyasu
    Inomata, Minoru
    Kuse, Naoyuki
    Sakamoto, Keita
    Kumasaka, Toshio
    Izumo, Takehiro
    RESPIRATORY INVESTIGATION, 2024, 62 (04) : 617 - 622
  • [4] Fetal ciliopathies: a retrospective observational single-center study
    Corinna Simonini
    Anne Floeck
    Brigitte Strizek
    Andreas Mueller
    Ulrich Gembruch
    Annegret Geipel
    Archives of Gynecology and Obstetrics, 2022, 306 : 71 - 83
  • [5] Fetal teratomas - A retrospective observational single-center study
    Simonini, Corinna
    Strizek, Brigitte
    Berg, Christoph
    Gembruch, Ulrich
    Mueller, Andreas
    Heydweiller, Andreas
    Geipel, Annegret
    PRENATAL DIAGNOSIS, 2021, 41 (03) : 301 - 307
  • [6] Fetal ciliopathies: a retrospective observational single-center study
    Simonini, Corinna
    Floeck, Anne
    Strizek, Brigitte
    Mueller, Andreas
    Gembruch, Ulrich
    Geipel, Annegret
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2022, 306 (01) : 71 - 83
  • [7] Diagnostic accuracy of dermoscopy for 934 basal cell carcinomas: A single-center retrospective study
    Yuki, Akihiko
    Takatsuka, Sumiko
    Abe, Riichiro
    Takenouchi, Tatsuya
    JOURNAL OF DERMATOLOGY, 2023, 50 (01): : 64 - 71
  • [8] Spongiotic Pattern in Pemphigus: A Retrospective Observational Single-Center Study
    Preclaro, Ivan Arni C.
    Wu, Yu-Hung
    DERMATOPATHOLOGY, 2022, 9 (02): : 172 - 182
  • [9] Evaluating the Diagnostic Accuracy of the Alvarado Score and Abdominal Ultrasound for Acute Appendicitis: A Retrospective Single-Center Study
    Al-wageeh, Saleh
    Alyhari, Qasem Abdulkarem
    Ahmed, Faisal
    Altam, Abdulfattah
    Alshehari, Gubran
    Badheeb, Mohamed
    OPEN ACCESS EMERGENCY MEDICINE, 2024, 16 : 159 - 166
  • [10] MYOSITIS-SPECIFIC ANTIBODIES IN A RETROSPECTIVE SINGLE-CENTER OBSERVATIONAL STUDY
    Alvarez Troncoso, J.
    Carrasco Molina, S.
    Valdivieso, J.
    Nozal, P.
    Robles Marhuenda, A.
    Martinez Robles, E.
    Soto Abanades, C.
    Rios, J. J.
    Noblejas Mozo, A.
    Arnalich Fernandez, F.
    ANNALS OF THE RHEUMATIC DISEASES, 2021, 80 : 693 - 694