Temporal Association Between Atrial Fibrillation Burden in Cardiac Implantable Electronic Devices and the Risk of Heart Failure Hospitalization

被引:2
|
作者
Ahluwalia, Nikhil [1 ]
Koehler, Jodi [2 ]
Sarkar, Shantanu [2 ]
Vasudevan, Neethu [2 ]
Majumder, Shubha [2 ]
Landman, Sean R. [2 ]
Schilling, Richard J. [1 ]
机构
[1] St Bartholomews Hosp, Barts Hlth NHS Trust, London, England
[2] Medtronic Inc, Mounds View, MN USA
来源
关键词
atrial fibrillation; hospitalization; odds ratio; stroke; STRICT RATE CONTROL; TIME-COURSE; TACHYARRHYTHMIA; TACHYCARDIA; CARDIOMYOPATHY; ACCURACY; LENIENT;
D O I
10.1161/CIRCEP.124.012842
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Atrial fibrillation (AF) events in cardiac implantable electronic devices (CIEDs) are temporally associated with stroke risk. This study explores temporal differences in AF burden associated with HF hospitalization risk in patients with CIEDs. METHODS: Patients with HF events from the Optum de-identified Electronic Health Records from 2007 to 2021 and 120 days of preceding CIED-derived rhythm data from a linked manufacturer's data warehouse were included. AF burden >= 5.5 h/d was defined as an AF event. The AF event burden in the case period (days 1-30 immediately before the HF event) was considered temporally associated with the HF event and compared with the AF event burden in a temporally dissociated control period (days 91-120 before the HF event). The odds ratio for temporally associated HF events and the odds ratio associated with poorly rate-controlled AF (>110 bpm) were calculated. RESULTS: In total, 7257 HF events with prerequisite CIED data were included; 957 (13.2%) patients had AF events recorded only in either their case (763 [10.5%]) or control (194 [2.7%]) periods, but not both. The odds ratio for a temporally associated HF event was 3.93 (95% CI, 3.36-4.60). This was greater for an HF event with a longer stay of >3 days (odds ratio, 4.51 [95% CI, 3.57-5.68]). In patients with AF during both the control and case periods, poor AF rate control during the case period also increased HF event risk (1.78 [95% CI, 1.22-2.61]). In all, 222 of 4759 (5%) patients without AF events before their HF event had an AF event in the 10 days following. CONCLUSIONS: In a large real-world population of patients with CIED devices, AF burden was associated with HF hospitalization risk in the subsequent 30 days. The risk is increased with AF and an uncontrolled ventricular rate. Our findings support AF monitoring in CIED algorithms to prevent HF admissions.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Temporal association between atrial fibrillation burden in cardiac implantable electronic devices and the risk of heart failure hospitalization
    Ahluwalia, N.
    Schilling, R. J.
    Koehler, J.
    Majumder, S.
    Landman, S.
    Sarkar, S.
    EUROPEAN HEART JOURNAL, 2023, 44
  • [2] Assessing Interplay Between Atrial Fibrillation and Heart Failure in Patients With Cardiac Implantable Electronic Devices
    Marine, Joseph E.
    Yang, Eunice
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2022, 8 (02) : 194 - 196
  • [3] Association of Atrial Fibrillation Burden and Mortality Among Patients With Cardiac Implantable Electronic Devices
    Peigh, Graham
    Zhou, Jiani
    Rosemas, Sarah C.
    Roberts, Anthony I.
    Longacre, Colleen
    Trinh, Katherine
    Nayak, Tanvi
    Soderlund, Dana
    Passman, Rod S.
    CIRCULATION, 2024, 150 (05) : 350 - 361
  • [4] The intriguing relationships between atrial fibrillation and heart failure: insights from cardiac implantable electronic devices
    Mei, Davide Antonio
    Martella, Matteo
    Boriani, Giuseppe
    ACTA CARDIOLOGICA, 2025,
  • [5] Atrial fibrillation and remote monitoring through cardiac implantable electronic devices in heart failure patients
    Boriani, Giuseppe
    Imberti, Jacopo F.
    Vitolo, Marco
    EUROPEAN JOURNAL OF HEART FAILURE, 2020, 22 (03) : 554 - 556
  • [6] Serotonin antidepressants and atrial fibrillation burden from cardiac implantable electronic devices
    Koh, Youlin
    Kwok, Cecilia
    Voskoboinik, Aleksandr
    Kalman, Jonathan M.
    Wong, Michael
    JOURNAL OF ARRHYTHMIA, 2023, : 876 - 883
  • [7] Cryoballoon ablation of atrial fibrillation in patients with advanced systolic heart failure and cardiac implantable electronic devices
    Pruszkowska, Patrycja
    Lenarczyk, Radoslaw
    Gumprecht, Jakub
    Jedrzejczyk-Patej, Ewa
    Mazurek, Michal
    Kowalski, Oskar
    Sokal, Adam
    Podolecki, Tomasz
    Morawski, Stanislaw
    Streb, Witold
    Mitrega, Katarzyna
    Kalarus, Zbigniew
    KARDIOLOGIA POLSKA, 2018, 76 (07) : 1081 - 1088
  • [8] Risk of Atrial Fibrillation and Adverse Outcomes in Patients With Cardiac Implantable Electronic Devices
    Lee, So-Ryoung
    Lee, Ji Hyun
    Choi, Eue-Keun
    Jung, Eun-Kyung
    You, So-Jeong
    Oh, Seil
    Lip, Gregory Y. H.
    KOREAN CIRCULATION JOURNAL, 2024, 54 (01) : 13 - 27
  • [9] Temporal Association of Atrial Fibrillation With Cardiac Implanted Electronic Device Detected Heart Failure Status
    Capucci, Alessandro
    Wong, Jorge A.
    Gold, Michael R.
    Boehmer, John
    Ahmed, Rezwan
    Kwan, Brian
    Thakur, Pramodsingh H.
    Zhang, Yi
    Jones, Paul W.
    Healey, Jeffrey S.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2022, 8 (02) : 182 - 193
  • [10] Association of atrial fibrillation burden with rhythm control and stroke prevention interventions among patients with cardiac implantable electronic devices
    Peigh, G.
    Zhou, J.
    Roberts, A. I.
    Rosemas, S. C.
    Longacre, C.
    Schwab, G.
    Soderlund, D.
    Passman, R. S.
    EUROPEAN HEART JOURNAL, 2023, 44