Revision Total Knee Arthroplasty With an Imageless, Second-Generation Robotic System

被引:0
|
作者
Cochrane, Niall H. [1 ]
Kim, Billy I. [1 ]
Stauffer, Taylor P. [1 ]
Hallows, Rhett K. [1 ]
Urish, Kenneth L. [2 ,3 ,4 ,5 ]
Alba, Jaime A. Carvajal [6 ]
Seyler, Thorsten M. [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Orthopaed Surg, 2301 Erwin Rd, Durham, NC 27710 USA
[2] Univ Pittsburgh, Med Ctr, Magee Womens Hosp, Ctr Bone & Joint,Arthrit & Arthroplasty Design Gr, Pittsburgh, PA USA
[3] Univ Pittsburgh, Dept Orthopaed Surg, Pittsburgh, PA USA
[4] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA USA
[5] Univ Pittsburgh, Clin & Translat Sci Inst, Pittsburgh, PA USA
[6] Univ Miami Hlth Syst, Dept Orthopaed Surg, Miami, FL USA
来源
JOURNAL OF ARTHROPLASTY | 2024年 / 39卷 / 08期
关键词
revision knee arthroplasty; robotics; second-generation; imageless; 90-day outcomes; CLINICAL-OUTCOMES; UNITED-STATES; REPLACEMENT; READMISSION; DISCHARGE; TRENDS; RATES; TKA;
D O I
10.1016/j.arth.2024.02.018
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Robotic-assisted total knee arthroplasty is increasingly used in revision total knee arthroplasty (rTKA), with imageless systems recently receiving Food and Drug Administration (FDA) approval. However, there remains a paucity of literature on the use of robotic assistance in revision total knee arthroplasty (TKA). This paper describes the imageless surgical technique for robotic revision TKA using a second-generation robotic system and details both intraoperative and 90-day outcomes. Methods: This was a retrospective review of 115 robotic revision TKAs from March 2021 to May 2023 at 3 tertiary academic centers. Patient demographics, perioperative surgical data, and 90-day outcomes were collected. Pain and Patient-Reported Outcomes Measurement Information System scores preoperatively and postoperatively were recorded. All-cause reoperations at the final follow-up were detailed. The mean patient age was 65 years (range, 43 to 88), and 58% were women. The mean follow-up time was 13 months (range, 3 to 51). Results: The most common indications for rTKA were instability (n = 37, 32%) and aseptic loosening (n = 42, 37%). There were 83 rTKAs to a posterior-stabilized liner, 22 to a varus-valgus constrained liner, and 5 to a hinged construct. The median polyethylene size was 11 (interquartile range, 10 to 13), and 93% of patients had their joint line restored within 5 millimeters of the native contralateral knee. Within the 90-day postoperative window, there were 8 emergency department visits and 2 readmissions. At the final follow-up, there were 5 reoperations and 2 manipulations under anesthesia. There were 4 patients who required irrigation and debridement after superficial wound dehiscence, and one had an arthrotomy disruption after a fall. Conclusions: This review demonstrates favorable intraoperative and 90-day outcomes and suggests that imageless robotic surgery is a promising modality in rTKA. Further studies comparing the longitudinal outcomes after robotic and conventional rTKA are warranted. (c) 2024 Elsevier Inc. All rights reserved.
引用
收藏
页码:S276 / S280
页数:5
相关论文
共 50 条
  • [1] A Cost Analysis of Traditional Versus Robotic Total Knee Arthroplasty Performed With an Imageless, Second-generation Robotic System
    Leal, Jaustin
    Cochrane, Niall H.
    Kim, Billy I.
    Holland, Christopher T.
    Hallows, Rhett
    Seyler, Thorsten
    ORTHOPEDICS, 2024, 47 (06) : 365 - +
  • [2] Comparing a robotic imageless second-generation system to traditional instrumentation in total knee arthroplasty: A matched cohort analysis
    Cochrane, Niall H.
    Kim, Billy I.
    Leal, Justin
    Hallows, Rhett K.
    Seyler, Thorsten M.
    JOURNAL OF ORTHOPAEDICS, 2024, 57 : 1 - 7
  • [3] Achieving functional alignment in total knee arthroplasty: early experience using a second-generation imageless semi-autonomous handheld robotic sculpting system
    Bollars, Peter
    Meshram, Prashant
    Al Thani, Saeed
    Schotanus, Martijn G. M.
    Albelooshi, Ali
    INTERNATIONAL ORTHOPAEDICS, 2023, 47 (02) : 585 - 593
  • [4] Achieving functional alignment in total knee arthroplasty: early experience using a second-generation imageless semi-autonomous handheld robotic sculpting system
    Peter Bollars
    Prashant Meshram
    Saeed Al Thani
    Martijn G. M. Schotanus
    Ali Albelooshi
    International Orthopaedics, 2023, 47 : 585 - 593
  • [5] Imageless Robotic Knee Arthroplasty
    Wu, Mark
    Charalambous, Lefko
    Penrose, Colin
    Belay, Elshaday
    Seyler, Thorsten M.
    OPERATIVE TECHNIQUES IN ORTHOPAEDICS, 2021, 31 (04)
  • [6] Development and Underlying Structure of a Second-Generation Appropriateness Classification System for Total Knee Arthroplasty
    Martinez, Antonio Escobar
    Perera, Robert A.
    Riddle, Daniel L.
    ARTHRITIS CARE & RESEARCH, 2021, 73 (06) : 801 - 809
  • [7] Development of an imageless navigation system for total knee arthroplasty
    Su Yingying
    Wang Chengtao
    Qi Yuanshuai
    Yan Shiju
    Gu Lixu
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 6060 - 6063
  • [8] Validation of a second-generation appropriateness classification system for total knee arthroplasty: a prospective cohort study
    Escobar, Antonio
    Bilbao, Amaia
    Bertrand, Maria L.
    Moreta, Jesus
    Froufe, Miquel A.
    Colomina, Jordi
    Martinez-Cruz, Olga
    Perera, Robert A.
    Riddle, Daniel L.
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [9] Validation of a second-generation appropriateness classification system for total knee arthroplasty: a prospective cohort study
    Antonio Escobar
    Amaia Bilbao
    Maria L. Bertrand
    Jesús Moreta
    Miquel A. Froufe
    Jordi Colomina
    Olga Martınez-Cruz
    Robert A. Perera
    Daniel L. Riddle
    Journal of Orthopaedic Surgery and Research, 16
  • [10] Accuracy and learning curve of imageless robotic-assisted total knee arthroplasty
    Bosco, Francesco
    Rovere, Giuseppe
    Burgio, Carmelo
    Bue, Giorgia Lo
    Cobisi, Claudio Domenico
    Via, Riccardo Giai
    Lucenti, Ludovico
    Camarda, Lawrence
    JOURNAL OF ORTHOPAEDICS, 2025, 66 : 77 - 83