Noise-robust analysis of X-Ray absorption near-edge structure based on poisson distribution

被引:0
|
作者
Kashiwamura, Shuhei [1 ]
Katakami, Shun [2 ]
Yamasaki, Taiga [3 ]
Iwamitsu, Kazunori [4 ]
Kumazoe, Hiroyuki [5 ]
Nagata, Kenji [6 ]
Okajima, Toshihiro [7 ]
Akai, Ichiro [8 ]
Okada, Masato [2 ]
机构
[1] Univ Tokyo, Grad Sch Sci, Bunkyo, Tokyo, Japan
[2] Univ Tokyo, Grad Sch Frontier Sci, Kashiwa, Chiba 2778561, Japan
[3] Kumamoto Univ, Grad Sch Sci & Technol, Kumamoto, Japan
[4] Nara Inst Sci & Technol, Grad Sch Adv Sci & Technol, Ikoma, Japan
[5] Hitotsubashi Univ, Grad Sch Social Data Sci, Kunitachi, Tokyo, Japan
[6] Natl Inst Mat Sci, Ctr Basic Res Mat, Tsukuba, Ibaraki, Japan
[7] Aichi Synchrotron Radiat Ctr, Seto, Japan
[8] Kumamoto Univ, Inst Ind Nanomat, Kumamoto, Japan
基金
日本学术振兴会;
关键词
Bayesian statistics; XANES; poisson distribution; exchange Monte Carlo method; solid electrolyte; MONTE-CARLO METHOD; SPECTROSCOPY; SELECTION;
D O I
10.1080/27660400.2024.2397939
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
We demonstrate that the noise tolerance of X-ray absorption near-edge structure (XANES) analysis can be improved by reconsidering the noise model. XANES measurement is a powerful technique to investigate the structure and electronic state of materials. In XANES measurements, the incident photon number and the absorbed photon number are measured, and the ratio of the two (called the absorption factor) is analyzed. The conventional analytical method involves fitting by the least-squares method, in which the stochastic noise is assumed to conform to a Gaussian distribution. We propose a framework for XANES analysis using a Poisson distribution as a likelihood model, focusing on the number of absorbed photons rather than the absorption factor. We validate the effectiveness of our method in numerical experiments. Moreover, we apply our method to actual solid electrolyte material data and demonstrate its practicality.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] X-ray Absorption Near-Edge Structure (XANES) Spectroscopy
    Henderson, Grant S.
    de Groot, Frank M. F.
    Moulton, Benjamin J. A.
    SPECTROSCOPIC METHODS IN MINERALOLOGY AND MATERIALS SCIENCES, 2014, 78 : 75 - +
  • [2] CALCULATION OF X-RAY ABSORPTION NEAR-EDGE STRUCTURE, XANES
    DURHAM, PJ
    PENDRY, JB
    HODGES, CH
    COMPUTER PHYSICS COMMUNICATIONS, 1982, 25 (02) : 193 - 205
  • [3] X-RAY ABSORPTION NEAR-EDGE STRUCTURE OF METAL-HYDRIDES
    LENGELER, B
    ZELLER, R
    JOURNAL OF THE LESS-COMMON METALS, 1984, 103 (02): : 337 - 347
  • [4] AN UPDATE OF DLXANES, THE CALCULATION OF X-RAY ABSORPTION NEAR-EDGE STRUCTURE
    VVEDENSKY, DD
    SALDIN, DK
    PENDRY, JB
    COMPUTER PHYSICS COMMUNICATIONS, 1986, 40 (2-3) : 421 - 440
  • [5] Pb speciation and elemental distribution in leeks by micro X-ray fluorescence and X-ray absorption near-edge structure
    Sun, Jianling
    Yang, Yongqiang
    Luo, Liqiang
    JOURNAL OF SYNCHROTRON RADIATION, 2023, 30 (05) : 934 - 940
  • [6] Pb speciation and elemental distribution in leeks by micro X-ray fluorescence and X-ray absorption near-edge structure
    Sun, Jianling
    Yang, Yongqiang
    Luo, Liqiang
    JOURNAL OF SYNCHROTRON RADIATION, 2023, 30 : 934 - 940
  • [7] MULTIELECTRON CONTRIBUTION TO NEAR-EDGE X-RAY ABSORPTION
    STERN, EA
    PHYSICAL REVIEW LETTERS, 1982, 49 (18) : 1353 - 1356
  • [8] Near-edge X-ray absorption fine structure of PdO at OK-edge
    Mogi, M
    Inoue, Y
    Yamamoto, T
    Tanaka, I
    Nachimuthu, P
    Perera, RCC
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2005, 44 (6A): : 4057 - 4059
  • [10] X-RAY ABSORPTION NEAR-EDGE STRUCTURE AND EXTENDED X-RAY ABSORPTION FINE-STRUCTURE INVESTIGATION OF PD SILICIDES
    DECRESCENZI, M
    COLAVITA, E
    DELPENNINO, U
    SASSAROLI, P
    VALERI, S
    RINALDI, C
    SORBA, L
    NANNARONE, S
    PHYSICAL REVIEW B, 1985, 32 (02): : 612 - 622