Functional Acetabular Component Positioning During Direct Anterior Approach Hip Arthroplasty Using a Novel Three-Dimensional Virtual Mesh Imaging System With Fluoroscopy

被引:0
|
作者
Coxe, Francesca R. [1 ]
Jordan, L. Andrew [1 ]
Wong, Zachary P. [1 ]
Spaan, Jonathan C. [1 ]
Ren, Renee [2 ]
Su, Edwin P. [1 ]
机构
[1] Hosp Special Surg, Div Adult Reconstruct & Joint Replacement, 535 E 70th St, New York, NY 10021 USA
[2] Icahn Sch Med Mt Sinai, New York, NY 10029 USA
来源
JOURNAL OF ARTHROPLASTY | 2024年 / 39卷 / 09期
关键词
total hip arthroplasty; navigation; technology; radiographic outcomes; component positioning; PELVIC TILT; SAFE ZONE; RADIOGRAPHIC CALCULATION; CUP; PLACEMENT; ORIENTATION; DISLOCATION; THA; REPLACEMENT; NAVIGATION;
D O I
10.1016/j.arth.2024.03.042
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Optimal position of total hip arthroplasty (THA) components is critical for joint mechanics and stability. Acetabular component positioning during supine surgery in direct anterior approach (DAA) THA may be different in the standing position postoperatively, which traditional fluoroscopy is unable to predict. A novel 3-dimensional (3D) image analysis technology (IAT) that uses artificial intelligence to measure the tilt and rotation of the pelvis has enabled prediction of component positioning from supine to standing. The purpose of this study was to compare intraoperative fluoroscopy, non-3D-IAT, and 3D-IAT with postoperative standing radiographs to assess the accuracy of component positioning. Methods: From 2022 to 2023, 30 consecutive patients (86.6% women, mean age 59 [range, 55 to 67]) undergoing primary DAA THA with the use of the 3D-IAT were identified. A separate cohort of 148 patients from 2020 to 2021 (85% women, mean age 65 [range, 55 to 69]) who underwent DAA THA with non-3D-IAT was used for comparison. Leg length discrepancy (LLD), cup anteversion, and inclination were manually measured on intraoperative fluoroscopic images and digitally measured using IAT. Follow-up evaluation occurred at 1 month with standing pelvis radiographs measured using Ein Bild Rontgen Analyze-Cup software. Measurements were compared via Wilcoxon signed rank tests where P <= .05 indicates significantly different measurements. Results: Median LLD, inclination, and anteversion measurements via non-3D-IAT and fluoroscopy were significantly different compared to postoperative standing radiographs (P < .001). The 3D-IAT more accurately predicted LLD, abduction, and anteversion, with values not significantly different from post-operative standing measurements (P = .23, P = .93, and P = .36, respectively). Conclusions: The use of the 3D-IAT during DAA THA allowed for the more accurate prediction of acetabular component position in the standing position postoperatively.
引用
收藏
页码:S88 / S96
页数:9
相关论文
共 30 条
  • [1] Acetabular and Femoral Component Positioning Using Direct Anterior Approach Versus Posterior Approach in Total Hip Arthroplasty
    Tarun Goyal
    Arghya Kundu Choudhury
    Souvik Paul
    Tushar Gupta
    Lakshmana Das
    Indian Journal of Orthopaedics, 2021, 55 : 1215 - 1224
  • [2] Acetabular and Femoral Component Positioning Using Direct Anterior Approach Versus Posterior Approach in Total Hip Arthroplasty
    Goyal, Tarun
    Choudhury, Arghya Kundu
    Paul, Souvik
    Gupta, Tushar
    Das, Lakshmana
    INDIAN JOURNAL OF ORTHOPAEDICS, 2021, 55 (05) : 1215 - 1224
  • [3] Anatomic Navigation Using the Transverse Acetabular Ligament for Acetabular Component Positioning in Total Hip Arthroplasty Through the Direct Anterior Approach
    Molho, David A.
    Kuether, Justin P.
    Rubin, Lee E.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2022, 30 (03) : 100 - 103
  • [4] Accuracy of Fluoroscopic Guided Acetabular Component Positioning During Direct Anterior Total Hip Arthroplasty
    Slotkin, Eric M.
    Patel, Preetesh D.
    Suarez, Juan C.
    JOURNAL OF ARTHROPLASTY, 2015, 30 (09): : 102 - 106
  • [5] Does Intraoperative Fluoroscopy Improve Limb-Length Discrepancy and Acetabular Component Positioning During Direct Anterior Total Hip Arthroplasty?
    Bingham, Joshua S.
    Spangehl, Mark J.
    Hines, Jeremy T.
    Taunton, Michael J.
    Schwartz, Adam J.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (09): : 2927 - 2931
  • [6] Three-Dimensional Templating for Acetabular Component Alignment During Total Hip Arthroplasty
    Elbuluk, Ameer M.
    Wojack, Paul
    Eftekhary, Nima
    Vigdorchik, Jonanathan M.
    ORTHOPEDICS, 2017, 40 (04) : E708 - E713
  • [7] Does the thigh circumference affect the positioning of the acetabular component when using the direct anterior approach in total hip arthroplasty?
    Jacobs, C. A.
    Kusema, E. T.
    Keeney, B. J.
    Moschetti, W. E.
    BONE & JOINT JOURNAL, 2019, 101B (05): : 529 - 535
  • [8] Real-Time Fluoroscopic Navigation Improves Acetabular Component Positioning During Direct Anterior Approach Total Hip Arthroplasty
    Herrero, Christina
    Lavery, Jessica A.
    Anoushiravani, Afshin A.
    Davidovitch, Roy, I
    BULLETIN OF THE HOSPITAL FOR JOINT DISEASES, 2021, 79 (02): : 78 - 83
  • [9] Accuracy of Implant Positioning in Total Hip Arthroplasty via a Supine Direct Anterior Approach Using Fluoroscopy
    Kanno, Keijiro
    Hagiwara, Shigeo
    Shiko, Yuki
    Kawarai, Yuya
    Nakamura, Junichi
    Ohtori, Seiji
    ADVANCES IN ORTHOPEDICS, 2025, 2025 (01)
  • [10] The effect of c-arm tilt on accuracy of intraoperative fluoroscopy in assessing acetabular component position during direct anterior approach for hip arthroplasty
    Jang, Eugene S.
    Lin, James D.
    Shah, Roshan P.
    Geller, Jeffrey A.
    Cooper, H. John
    JOURNAL OF ORTHOPAEDICS, 2018, 15 (02) : 447 - 449