Comparison of 3D-Printed Single Crown Outcomes Among Different Computer-Aided Design Software Programs

被引:0
|
作者
No-Cortes, Juliana [1 ]
Attard, Bonnie [2 ]
Mifsud, David Paul [3 ]
Lima, Jacqueline Ferreira
Markarian, Roberto Adrian
Ayres, Ana Paula [4 ]
Cassar, Glenn [2 ]
Cortes, Arthur Rodriguez Gonzalez [5 ]
Attard, Nikolai John [3 ]
机构
[1] Univ Malta, Dept Restorat Dent, Fac Dent Surg, Msida, Malta
[2] Univ Malta, Dept Met & Mat Engn, Fac Engn, Msida, Malta
[3] Univ Malta, Fac Dent Surg, Dept Oral Rehabil & Community Care, Msida, Malta
[4] Univ Sao Paulo, Sch Dent, Dept Stomatol, Sao Paulo, SP, Brazil
[5] Univ Malta, Fac Dent Surg, Dept Dent Surg, Msida, Malta
关键词
EXPERTISE;
D O I
10.11607/ijp.8718
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Low- cost resin 3D printers have been used to produce affordable interim single crowns in public and private dental practices. The purpose of this study was to assess the impact of different computer-aided design (CAD) software programs on 3D trueness, microscopic marginal and internal gaps, time to design, and interproximal contacts of low-cost 3D-printed single crowns. Materials and Methods: This in vitro study was performed on a total of 90 standardized resin-prepared teeth adapted to a dental manikin. For comparison among CAD software programs, 45 tooth preparations received 3D-printed crowns designed with one of three CAD software programs by an experienced technician and identified as groups TRIOS (n = 15), EXOCAD (n = 15), and ZZ (Zirkonzahn; n = 15). To assess interoperator reproducibility, 15 additional crowns were designed by a dental clinician (group ZZ- DENT) and 15 by a dental prosthetic technician (group ZZ-PROS), both with basic 1-week CAD/CAM training. Finally, as a control group, 15 crowns were milled using a high-end five-axis milling device (group ZZ-CONTROL). Statistically significant differences for 3D trueness, microscopic gaps, time to design, and interproximal contacts among groups were assessed with the Kruskal-Wallis test. Results: No statistically significant differences in 3D trueness or marginal or internal gaps were found, either among different software programs or CAD operators (P >.05). However, Group TRIOS took significantly longer to design than EXOCAD and ZZ groups (P =.001). Less-experienced operators were significantly outperformed in time and interproximal contacts (P =.001) by the CAD technician using the same software program. Finally, control milled crowns (ZZ-CONTROL) significantly outperformed the respective 3D-printed copies (ZZ) in all assessed variables (P <.001). Conclusions: Different CAD software programs may affect the time required to design, but they do not significantly affect clinical outcomes of low-cost 3D-printed resin crowns if designed by an experienced CAD technician.
引用
收藏
页码:S63 / S70
页数:8
相关论文
共 50 条
  • [1] COMPARISON OF 3 COMPUTER-AIDED DESIGN PROGRAMS
    DICKHAUT, RH
    ELECTRO-TECHNOLOGY, 1967, 79 (01): : 88 - &
  • [2] Designing a Single Lithium Disilicate Crown: A Computer-Aided Design and Computer-Aided Manufacturing Approach With Exocad Software
    Gorripati, Jahnavi P.
    Dubey, Surekha A. Godbole
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (04)
  • [3] Workflow and treatment results for computer-aided design and 3D-printed conformer therapy of congenital anophthalmia and microphthalmia
    Groot, Annabel L. W.
    Remmers, Jelmer S.
    Lissenberg-Witte, Birgit, I
    de Meulenaere, Simon T. J.
    Talan, Duygu
    Liberton, Niels P. T. J.
    de Graaf, Pim
    Moll, Annette C.
    Saeed, Peerooz
    Hartong, Dyonne T.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2023, 107 (09) : 1239 - 1245
  • [4] 2D and 3D patient's representation of simulated restorative esthetic outcomes using different computer-aided design software programs: A systematic review
    Piedra-Cascon, Wenceslao
    Fountain, Joshua
    Att, Wael
    Revilla-Leon, Marta
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2021, 33 (01) : 143 - 151
  • [5] Application of computer-aided design and 3D-printed template for accurate bone augmentation in the aesthetic region of anterior teeth
    Xin Liu
    Zhou Fang
    Jin Feng
    Se-fei Yang
    Yi-peng Ren
    BMC Oral Health, 23
  • [6] Application of computer-aided design and 3D-printed template for accurate bone augmentation in the aesthetic region of anterior teeth
    Liu, Xin
    Fang, Zhou
    Feng, Jin
    Yang, Se-fei
    Ren, Yi-peng
    BMC ORAL HEALTH, 2023, 23 (01)
  • [7] Computer-Aided Design of 3D-Printed Clay-Based Composite Mortars Reinforced with Bioinspired Lattice Structures
    Kladovasilakis, Nikolaos
    Pemas, Sotirios
    Pechlivani, Eleftheria Maria
    BIOMIMETICS, 2024, 9 (07)
  • [8] FORMAL STRUCTURE OF THE DESIGN PROCESS AND SOFTWARE IN INDUSTRIAL COMPUTER-AIDED DESIGN PROGRAMS.
    Gakh, V.Ya.
    Krutitskii, A.Yu.
    1600,
  • [10] Comparison of the morphological accuracy of automatic crowns designed by multiple computer-aided design software programs with different levels of dentition information acquisition
    Wang, Fang
    Zhang, Teng
    Zhou, Qin
    Lu, Yi
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (02): : 441 - 452