Thermography measurement for bridge displacement in the darkness using power-free target

被引:1
|
作者
Su, Ziyang [1 ]
Wang, Linqing [1 ]
Zhang, Jian [1 ,2 ]
机构
[1] Southeast Univ, Sch Civil Engn, Nanjing 210096, Peoples R China
[2] Southeast Univ, Jiangsu Key Lab Engn Mech, Nanjing 210096, Peoples R China
关键词
Thermography; Power-free target; Displacement measurement; Elliptic center positioning; INFRARED THERMOGRAPHY;
D O I
10.1016/j.engstruct.2024.118185
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Vision-based displacement measurement has become increasingly popular in bridge health assessment. However, this technology faces challenge that a complicated power-consuming supply system must be installed in the darkness, making it unable to meet the needs of low energy consumption and low cost. This paper proposes a bridge displacement measurement method using power-free target and thermography to address it. First, a thermography measurement system for bridge displacement in the darkness is developed. The power-free target with a hollowed-out circular feature is adopted to form the contrast to the background, and graphene is coated on the target surface to enhance the infrared emissivity and contrast further. Second, a sub-pixel elliptic center positioning algorithm based on thermography enhancement and data optimization is proposed to improve the accuracy and the ability to resist occlusion. The feasibility of the method is verified by laboratory tests and bridge field tests. When the measurement distance is within 15 m, the results meet the engineering error requirements of 5%, with the prospect of popularization in small and medium-sized bridges displacement measurement.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Electric power generation using piezoelectric resonator for power-free sensor node
    Tanaka, H
    Ono, G
    Nagano, T
    Ohkubo, N
    CICC: PROCEEDINGS OF THE IEEE 2005 CUSTOM INTEGRATED CIRCUITS CONFERENCE, 2005, : 97 - 100
  • [2] Bridge Displacement Monitoring using Acceleration Measurement for Efficient Bridge Management
    Umekawa, Y.
    Suganuma, H.
    MAINTENANCE, SAFETY, RISK, MANAGEMENT AND LIFE-CYCLE PERFORMANCE OF BRIDGES, 2018, : 1710 - 1717
  • [3] Sensitivity Enhancement of MicroRNA Detection Using a Power-free Microfluidic Chip
    Young-Jin Kim
    Kazuo Hosokawa
    Mizuo Maeda
    Analytical Sciences, 2019, 35 : 1227 - 1236
  • [4] Sensitivity Enhancement of MicroRNA Detection Using a Power-free Microfluidic Chip
    Kim, Young-Jin
    Hosokawa, Kazuo
    Maeda, Mizuo
    ANALYTICAL SCIENCES, 2019, 35 (11) : 1227 - 1236
  • [5] BRIDGE DISPLACEMENT MEASUREMENT SYSTEM USING IMAGE PROCESSING
    Lee, J. W.
    Kwark, J. W.
    Choi, E. S.
    Chin, W. J.
    Lee, J. W.
    PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON STRUCTURE HEALTH MONITORING & INTELLIGENT INFRASTRUCTURE: STRUCTURAL HEALTH MONITORING & INTELLIGENT INFRASTRUCTURE, 2007,
  • [6] Design of a bidirectional MEMS actuator with high displacement resolution, large driving force and power-free latching
    Wang, Welsong
    Tatic-Lucic, Svetlana
    Brown, Walter L.
    Vinci, Richard
    MICROELECTRONIC ENGINEERING, 2008, 85 (03) : 587 - 598
  • [7] Power-free, digital and programmable dispensing of picoliter droplets using a Digit Chip
    Mepham, A.
    Besant, J. D.
    Weinstein, A. W.
    Burgess, I. B.
    Sargent, E. H.
    Kelley, S. O.
    LAB ON A CHIP, 2017, 17 (08) : 1505 - 1514
  • [8] Portable and power-free serodiagnosis of Chagas disease using magnetic levitating microbeads
    Castro, Beatriz
    de Medeiros, Marina Sala
    Sadri, Behnam
    Martinez, Ramses V.
    ANALYST, 2018, 143 (18) : 4379 - 4386
  • [9] Target-Triggered Ultrafast Chondroitin Gelation Enabled Power-Free and Point-of-Care Bioassays
    Qi, Chunjiao
    Chen, Jintao
    Shang, Yuhui
    Yang, Yu
    Wang, Kangyan
    Chen, Jinyang
    ANALYTICAL CHEMISTRY, 2024, 96 (44) : 17781 - 17788
  • [10] Monitoring system of the Akashi Kaikyo Bridge and displacement measurement using GPS
    Fujino, Y
    Murata, M
    Okano, S
    Takeguchi, M
    NONDESTRUCTIVE EVALUATION OF HIGHWAYS, UTILITIES, AND PIPELINES IV, 2000, 3995 : 229 - 236