Biological reliability of a movement analysis assessment using a markerless motion capture system

被引:0
|
作者
Philipp, Nicolas M. [1 ]
Fry, Andrew C. [1 ]
Mosier, Eric M. [2 ]
Cabarkapa, Dimitrije [1 ]
Nicoll, Justin X. [3 ]
Sontag, Stephanie A. [4 ]
机构
[1] Univ Kansas, Jayhawk Athlet Performance Lab, Wu Tsai Human Performance Alliance, Lawrence, KS 66045 USA
[2] Washburn Univ, Kinesiol Dept, Topeka, KS USA
[3] Calif State Univ Northridge, Dept Kinesiol, Los Angeles, CA USA
[4] Oklahoma State Univ, Sch Kinesiol, Appl Hlth & Recreat, Stillwater, OK USA
来源
关键词
biomechanics; motion capture; movement screen; human movement; reliability; JOINT MOTION; ACCURACY;
D O I
10.3389/fspor.2024.1417965
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Introduction: Advances in motion capture technology include markerless systems to facilitate valid data collection. Recently, the technological reliability of this technology has been reported for human movement assessments. To further understand sources of potential error, biological reliability must also be determined. The aim of this study was to determine the day-to-day reliability for a three-dimensional markerless motion capture (MMC) system to quantify 4 movement analysis composite scores, and 81 kinematic variables. Methods: Twenty-two healthy men (n = 11; X-(sic)+/- SDX(sic)+/- SD; age = 23.0 +/- 2.6 years, height = 180.4.8 cm, weight = 80.4 +/- 7.3 kg) and women (n = 11; age = 20.8 +/- 1.1 years, height = 172.2 +/- 7.4 cm, weight = 68.0 +/- 7.3 kg) participated in this study. All subjects performed 4 standardized test batteries consisting of 14 different movements on four separate days. A three-dimensional MMC system (DARI Motion, Lenexa, KS) using 8 cameras surrounding the testing area was used to quantify movement characteristics. 1 x 4 RMANOVAs were used to determine significant differences across days for the composite movement analysis scores, and RM-MANOVAs were used to determine test day differences for the kinematic data (p < 0.05). Intraclass correlation coefficients (ICCs) were reported for all variables to determine test reliability. To determine biological variability, mean absolute differences from previously reported technological variability data were subtracted from the total variability data from the present study. Results: No differences were observed for any composite score (i.e., athleticism, explosiveness, quality, readiness; or any of the 81 kinematic variables. Furthermore, 84 of 85 measured variables exhibited good to excellent ICCs (0.61-0.99). When compared to previously reported technological variability data, 62.3% of item variability was due to biological variability, with 66 of 85 variables exhibiting biological variability as the primary source of error (i.e., >50% total variability). Discussion: Combined, these findings effectively add to the body of literature suggesting sufficient reliability for MMC solutions in capturing kinematic features of human movement.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Reliability of Markerless Motion Capture Systems for Assessing Movement Screenings
    Hauenstein, Jonathan D.
    Huebner, Alan
    Wagle, John P.
    Cobian, Emma R.
    Cummings, Joseph
    Hills, Caroline
    Mcginty, Megan
    Merritt, Mandy
    Rosengarten, Sam
    Skinner, Kyle
    Szemborski, Michael
    Wojtkiewicz, Leigh
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2024, 12 (03)
  • [2] Validity and Reliability of Upper Limb Kinematic Assessment Using a Markerless Motion Capture (MMC) System: A Pilot Study
    Lam, Winnie W. T.
    Fong, Kenneth N. K.
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2024, 105 (04): : 673 - 681.e2
  • [3] Test-Retest Reliability of Performance Scores Using a Markerless Motion Capture System
    Mosier, Eric M.
    Fry, Andrew C.
    Nicoll, Justin X.
    Cabarkapa, Dimitrije
    Sontag, Stephanie A.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2019, 51 (06): : 61 - 61
  • [4] Assessment of Bilateral Shoulder Range of Motion in Firefighter Trainees Using a Markerless Motion Capture System
    Howard, Conner
    Kahnt, Alexis
    Volberding, Jennifer L.
    Dawes, Jay
    INTERNATIONAL JOURNAL OF ATHLETIC THERAPY & TRAINING, 2023, 28 (05): : 263 - 268
  • [5] Vertical Jump Reliability With Markerless Motion Capture
    Edwards, Richard B.
    Taylor, Ava M.
    Westbrook, Audrey E.
    Ford, Kevin R.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2022, 54 (09) : 293 - 293
  • [6] Measuring human movement for biomechanical applications using markerless motion capture
    Mundermann, Lars
    Corazza, Stefano
    Chaudhari, Ajit M.
    Andriacchi, Thomas P.
    Sundaresan, Aravind
    Chellappa, Rama
    THREE-DIMENSIONAL IMAGE CAPTURE AND APPLICATIONS VII, 2006, 6056
  • [7] Accuracy of classifying the movement strategy in the functional reach test using a markerless motion capture system
    Tanaka R.
    Ishikawa Y.
    Yamasaki T.
    Diez A.
    Journal of Medical Engineering and Technology, 2019, 43 (02): : 133 - 138
  • [8] Markerless Motion Capture System to Detect Upper Limb Movement during Rehabilitation using Video Games
    McNamara, Kate
    Bo, Antonio Padilha Lanari
    McKittrick, Andrea
    Tornatore, Giovanna
    Laracy, Sue
    Desselle, Mathilde
    2022 IEEE 10TH INTERNATIONAL CONFERENCE ON SERIOUS GAMES AND APPLICATIONS FOR HEALTH(SEGAH' 22), 2022,
  • [9] Inter-Device Reliability of a Three-Dimensional Markerless Motion Capture System Quantifying Elementary Movement Patterns in Humans
    Philipp, Nicolas M.
    Cabarkapa, Dimitrije
    Cabarkapa, Damjana V.
    Eserhaut, Drake A.
    Fry, Andrew C.
    JOURNAL OF FUNCTIONAL MORPHOLOGY AND KINESIOLOGY, 2023, 8 (02)
  • [10] Reliability Of Markerless Motion Capture On The Kinematics Of A Drop Vertical Jump
    Ross, Kaley
    Valencia, Matthew P.
    Pexa, Brett S.
    Johnston, Christopher J.
    Taylor, Jeffrey B.
    Ford, Kevin R.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2023, 55 (09) : 63 - 64