Smartwatch step counting: impact on daily step-count estimation accuracy

被引:1
|
作者
Dueking, Peter [1 ]
Strahler, Jana [2 ]
Forster, Andre [3 ]
Wallmann-Sperlich, Birgit [4 ]
Sperlich, Billy [5 ]
机构
[1] Tech Univ Carolo Wilhelmina Braunschweig, Dept Sports Sci & Movement Pedag, Braunschweig, Germany
[2] Univ Freiburg, Sport Psychol, Dept Sport & Sport Sci, Freiburg, Germany
[3] Julius Maximilians Univ Wurzburg, Inst Psychol, Wurzburg, Germany
[4] Julius Maximilians Univ Wurzburg, Inst Sport Sci, Wurzburg, Germany
[5] Julius Maximilians Univ Wurzburg, Dept Sport Sci, Integrat & Expt Exercise Sci & Training, Wurzburg, Germany
来源
关键词
innovation; smartwatch; technology; wearable; eHealth; mHealth;
D O I
10.3389/fdgth.2024.1400369
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Introduction: The effect of displayed step count in smartwatches on the accuracy of daily step-count estimation and the potential underlying psychological factors have not been revealed. The study aimed for the following: (i) To investigate whether the counting and reporting of daily steps by a smartwatch increases the daily step-count estimation accuracy and (ii) to elucidating underlying psychological factors. Methods: A total of 34 healthy men and women participants wore smartwatches for 4 weeks. In week 1 (baseline), 3 (follow-up 1), and 8 (follow-up 2), the number of smartwatch displayed steps was blinded for each participant. In week 2 (Intervention), the number of steps was not blinded. During baseline and follow-ups 1 and 2, the participants were instructed to estimate their number of steps four times per day. During the 4-week wash-out period between follow-ups 1 and 2, no feedback was provided. The Body Awareness Questionnaire and the Body Responsiveness Questionnaire (BRQ) were used to elucidate the psychological facets of the assumed estimation accuracy. Results: The mean absolute percentage error between the participants' steps count estimations and measured steps counts were 29.49% (at baseline), 0.54% (intervention), 11.89% (follow-up 1), and 15.14% (follow-up 2), respectively. There was a significant effect between baseline and follow-up 1 [t (61.7) = 3.433, p < 0.001] but not between follow-up 1 and follow-up 2 [t (60.3) = -0.288, p = 0.774]. Only the BRQ subscale "Suppression of Bodily Sensations" appeared to be significant at the Baseline (p = 0.012; Bonferroni adjusted p = 0.048) as a factor influencing step-count estimation accuracy. Conclusion: The counting and reporting of daily steps with a smartwatch allows improving the subjective estimation accuracy of daily step counts, with a stabilizing effect for at least 6 weeks. Especially individuals who tend to suppress their bodily sensations are less accurate in their daily step-count estimation before the intervention.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Step-count Accuracy And Instrument Equivalence Of McDonalds' Stepometers
    Gao, Yong
    Boscolo, Marco
    Krahling, Heidi
    Zhu, Weimo
    Lee, Miyoung
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 : S117 - S117
  • [2] Step-Count Accuracy of 3 Motion Sensors for Older and Frail Medical Inpatients
    McCullagh, Ruth
    Dillon, Christina
    O'Connell, Ann Marie
    Horgan, N. Frances
    Timmons, Suzanne
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2017, 98 (02): : 295 - 302
  • [3] Validity of the actical accelerometer step-count function
    Esliger, Dale W.
    Probert, Adam
    Gorber, Sarah Connor
    Bryan, Shirley
    Laviolette, Manon
    Tremblay, Mark S.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2007, 39 (07): : 1200 - 1204
  • [4] Comparison of tri-axial accelerometers step-count accuracy in slow walking conditions
    Feng, Yuanyuan
    Wong, Christopher K.
    Janeja, Vandana
    Kuber, Ravi
    Mentis, Helena M.
    GAIT & POSTURE, 2017, 53 : 11 - 16
  • [5] Gait speed and step-count monitor accuracy in community-dwelling older adults
    Storti, Kristi L.
    Pettee, Kelley K.
    Brach, Jennifer S.
    Talkowsk, Jaime Berlin
    Richardson, Caroline R.
    Kriska, Andrea M.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2008, 40 (01): : 59 - 64
  • [6] Apple Watch 6 vs. Galaxy Watch 4: A Validity Study of Step-Count Estimation in Daily Activities
    Hong, Kyu-Ri
    Hwang, In-Whi
    Kim, Ho-Jun
    Yang, Seo-Hyung
    Lee, Jung-Min
    SENSORS, 2024, 24 (14)
  • [7] Validity of the Actical Accelerometer Step-Count Function in Children
    Rosenkranz, Richard R.
    Rosenkranz, Sara K.
    Weber, Casey
    PEDIATRIC EXERCISE SCIENCE, 2011, 23 (03) : 355 - 365
  • [8] Step-Count Guidelines for Children and Adolescents: A Systematic Review
    da Silva, Michael Pereira
    Fontana, Fabio Eduardo
    Callahan, Eric
    Mazzardo, Oldemar
    De Campos, Wagner
    JOURNAL OF PHYSICAL ACTIVITY & HEALTH, 2015, 12 (08): : 1184 - 1191
  • [9] Step-Count Accuracy of Physical Activity Monitors During Pregnancy in Free-Living Conditions
    Dahmen, Jordana B.
    Connolly, Christopher P.
    Montoye, Alexander H. K.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2017, 49 (05): : 832 - 832
  • [10] Pedometer-Determined Step-Count Guidelines for Afterschool Programs
    Beets, Michael W.
    Beighle, Aaron
    Bottai, Matteo
    Rooney, Laura
    Tilley, Fallon
    JOURNAL OF PHYSICAL ACTIVITY & HEALTH, 2012, 9 (01): : 71 - 77