Bone Transport for Large Segmental Tibial Defects Using Taylor Spatial Frame versus the Ilizarov Circular Fixator

被引:1
|
作者
Shi, Bowen [1 ,2 ]
Zhang, Zhongli [1 ,2 ,3 ]
Ji, Guoqi [2 ]
Cai, Chengkuo [2 ]
Shu, Hengsheng [2 ]
Ma, Xinlong [2 ]
机构
[1] Tianjin Med Univ, Clin Sch Orthoped, Tianjin, Peoples R China
[2] Tianjin Hosp, Dept Orthoped Traumatol, Tianjin 300200, Peoples R China
[3] Tianjin Hosp, Dept Pediat Orthoped, Tianjin, Peoples R China
关键词
Bone defects; Bone transport; External fixators; Ilizarov technique; Tibial fractures; DISTRACTION OSTEOGENESIS; INFECTED NONUNIONS; STACKED TRANSPORT; MANAGEMENT; DEFORMITY; CHILDREN; SITE;
D O I
10.1111/os.14192
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: Bone transport has become the gold standard for treating large segmental tibial bone defects. The technique for application the Ilizarov circular fixator (ICF) has a long learning curve and is associated with many complications. There are few clinical studies on bone transport via the Taylor spatial frame (TSF). The main purpose of this study was to compare the radiological and clinical and outcomes of bone transport by using the TSF and the ICF. Methods: There were 62 patients included in this retrospective study from June 2011 to June 2021 and distributed to two groups according to the fixation method: a TSF group consisting of 30 patients and an ICF group consisting of 32 patients. Demographic information, surgical duration, external fixation times, external fixation index, final radiographic results, complications, and clinical outcomes were recorded and examined. The clinical outcomes were assessed using the ASAMI criteria during the most recent clinical visit. Then, statistical analysis such as independent-samples t tests or chi-Square test was performed. Results: The mean surgical duration in the TSF group was 93.8 +/- 7.3 min, which was shorter than that in the ICF group (109.8 +/- 1.4 min) (p < 0.05). Compared to the ICF group (10.2 +/- 2.0 months), the TSF group (9.7 +/- 1.8 months) had a shorter average external fixation time (p > 0.05). The external fixation index was 1.4 +/- 0.2 m/cm and 1.5 +/- 0.1 m/cm in the two groups. Moreover, there was no significant difference between the two groups. At the last follow-up visit, the medial proximal tibial angle (MPTA) and posterior proximal tibial angle (PPTA) in the TSF group were 88.1 +/- 12.1 degrees and 80.9 +/- 1.3 degrees, respectively. The MPTA and PPTA in the ICF group were 84.4 +/- 2.4 degrees and 76.2 +/- 1.9 degrees, respectively. There were statistically significant differences between the two groups (all p < 0.05). The complication rate was 50% in the TSF group and 75% in the ICF group. Moreover, the ASAMI score between the two groups was no statistically significant difference (p > 0.05). Conclusion: No statistically significant difference was found in clinical outcomes between the use of Taylor spatial frame and Ilizarov circular fixator for treating large segmental tibial bone defects. However, TSF is a shorter and simpler procedure that causes fewer complications and improves limb alignment.
引用
收藏
页码:2157 / 2166
页数:10
相关论文
共 50 条
  • [1] Bone Transport for Postinfectious Segmental Tibial Bone Defects With a Combined Ilizarov/Taylor Spatial Frame Technique
    Sala, Francesco
    Thabet, Ahmed M.
    Castelli, Fabio
    Miller, Anna N.
    Capitani, Dario
    Lovisetti, Giovanni
    Talamonti, Tazio
    Singh, Saurabh
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (03) : 162 - 168
  • [2] Management of paediatric tibial fractures using two types of circular external fixator: Taylor spatial frame and Ilizarov circular fixator
    Tafazal, Suhayl
    Madan, Sanjeev S.
    Ali, Farhan
    Padman, Manoj
    Swift, Simone
    Jones, Stanley
    Fernandes, James A.
    JOURNAL OF CHILDRENS ORTHOPAEDICS, 2014, 8 (03) : 273 - 279
  • [3] Distraction osteogenesis for tibial nonunion with bone loss using combined Ilizarov and Taylor spatial frames versus a conventional circular frame
    Abuomira, Ibrahim Elsayed Abdellatif
    Sala, Francesco
    Elbatrawy, Yasser
    Lovisetti, Giovanni
    Alati, Salvatore
    Capitani, Dario
    STRATEGIES IN TRAUMA AND LIMB RECONSTRUCTION, 2016, 11 (03): : 153 - 159
  • [4] Segmental tibial fractures treated with Ilizarov circular fixator
    Tomic, Slavko
    Slavkovic, Nemanja
    Tulic, Goran
    Baljozovic, Andreja
    Jovanovic, Zelimir
    Mirkovic, Milan
    Rajkovic, Stanislav
    Bogosavljevic, Nikola
    Saponjski, Dusan
    Mihajlovic, Sladjana
    Jeremic, Danilo
    VOJNOSANITETSKI PREGLED, 2021, 78 (03) : 317 - 322
  • [5] Reconstruction of intercalary bone defects following bone tumor resection with segmental bone transport using an Ilizarov circular external fixator
    Demiralp, Bahtiyar
    Ege, Tolga
    Kose, Ozkan
    Yurttas, Yuksel
    Basbozkurt, Mustafa
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2014, 19 (06) : 1004 - 1011
  • [6] No difference in tibial lengthening index by use of Taylor Spatial Frame or Ilizarov external fixator
    Kristiansen, Leif Pal
    Steen, Harald
    Reikeras, Olav
    ACTA ORTHOPAEDICA, 2006, 77 (05) : 772 - 777
  • [7] Matched Comparison of Bone Transport Using External Fixator Over a Nail Versus External Fixator Over a Plate for Segmental Tibial Bone Defects
    Park, Kyeong-Hyeon
    Oh, Chang-Wug
    Kim, Joon-Woo
    Oh, Jong-Keon
    Yoon, Yong-Cheol
    Seo, Il
    Ha, Sung-Soo
    Chung, Seung-Ho
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2021, 35 (11) : E397 - E404
  • [8] Bone transport with an external fixator and a locking plate for segmental tibial defects
    Oh, C-W.
    Apivatthakakul, T.
    Oh, J-K.
    Kim, J-W.
    Lee, H-J.
    Kyung, H-S.
    Baek, S-G.
    Jung, G-H.
    BONE & JOINT JOURNAL, 2013, 95B (12): : 1667 - 1672
  • [9] Repair of tibial nonunions and bone defects with the Taylor Spatial Frame
    Rozbruch, S. Robert
    Pugsley, Jacob S.
    Fragomen, Austin T.
    Ilizarov, Svetlana
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (02) : 88 - 95
  • [10] The Art of Tibial Bone Transport Using the Ilizarov Fixator: The Suspension Wire Technique
    Tetsworth, Kevin D.
    Dlaska, Constantin E.
    TECHNIQUES IN ORTHOPAEDICS, 2015, 30 (03) : 142 - 155