Seismic retrofit of intact and damaged RC columns using prefabricated steel cage-reinforced UHPC jackets and NSM GFRP bars

被引:4
|
作者
Hou, Chunxu [1 ]
Ma, Gao [1 ,2 ]
Hwang, Hyeon-Jong [3 ]
Li, Suchao [4 ]
Kang, Su-Min [5 ]
机构
[1] Hunan Univ, Coll Civil Engn, Changsha 410082, Peoples R China
[2] Hunan Univ, Key Lab Damage Diag Engn Struct Hunan Prov, Changsha 410082, Hunan, Peoples R China
[3] Konkuk Univ, Sch Architecture, Seoul 05029, South Korea
[4] Harbin Inst Technol Weihai, Dept Civil Engn, Weihai 264209, Peoples R China
[5] Soongsil Univ, Sch Architecture, Seoul 06978, South Korea
基金
新加坡国家研究基金会; 中国国家自然科学基金;
关键词
Seismic performance; Damaged RC column; Prefabricated UHPC jacket; NSM; Retrofitting; GFRP; Flexural strength model; SURFACE-MOUNTED FRP; CONCRETE COLUMNS; PERFORMANCE; BEHAVIOR; STRENGTH; COMPOSITES;
D O I
10.1016/j.engstruct.2024.118665
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The use of high-performance materials, such as ultra-high-performance concrete (UHPC) and fiber-reinforced polymer (FRP), in the seismic retrofitting and strengthening of reinforced concrete (RC) columns has attracted wide attention. In this study, a novel prefabricated steel cage-reinforced UHPC jacket (PSRUJ) was proposed to improve the retrofitting efficiency of conventional cast-in-place UHPC jackets and combine the advantages of UHPC and steel jackets. PSRUJ was further combined with the near surface-mounted (NSM) technique to develop a new method for retrofitting the seismic performance of RC columns in buildings. To investigate the effectiveness of the proposed retrofitting method, cyclic loading tests were performed on one intact RC column retrofitted with PSRUJ and two damaged RC columns retrofitted with PSRUJ and the combination of PSRUJ and NSM glass FRP (GFRP) bars. After PSRUJ retrofitting, the load-carrying capacity, deformation capacity, and stiffness of the intact and damaged RC columns increased by (30 similar to 46)%, (54 similar to 74)%, and (24 similar to 40)%, respectively. The inclusion of NSM GFRP bars further increased the load-carrying capacity but reduced the residual drift ratio while having little effect on the ultimate drift ratio of the retrofitted columns. Further, a damage index was proposed to assess the damage degree of core normal concrete and develop the peak strength and strain models for PSRUJ-confined damaged concrete. Finally, a flexural strength model was proposed for damaged RC columns retrofitted with PSRUJ and NSM bars.
引用
收藏
页数:15
相关论文
共 44 条
  • [1] Retrofitting performance of precast UHPC jackets and NSM GFRP bars in pre-damaged RC columns with deficient lap splices
    Hou, Chunxu
    Ma, Gao
    Hwang, Hyeon-Jong
    Yang, Ou
    Kang, Su-Min
    ENGINEERING STRUCTURES, 2024, 320
  • [2] Retrofit of Damaged RC Columns Using CFRP Jackets
    Moretti, Marina L.
    Miliokas, Evangelos
    Paparizos, Ioannis
    10TH INTERNATIONAL CONFERENCE ON FRP COMPOSITES IN CIVIL ENGINEERING (CICE 2020/2021), 2022, 198 : 1229 - 1240
  • [3] Retrofit of Damaged RC Columns Using CFRP Jackets
    Moretti, Marina L.
    Miliokas, Evangelos
    Paparizos, Ioannis
    Lecture Notes in Civil Engineering, 2022, 198 LNCE : 1229 - 1240
  • [4] Seismic retrofitting of old-type RC columns with different lap splices by NSM GFRP and steel bars
    Seifi, Ali
    Hosseini, Abdollah
    Marefat, Mohammad Sadegh
    Khanmohammadi, Mohammad
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2018, 27 (02):
  • [5] Seismic retrofitting of RC columns using stainless steel grid-reinforced UHPC jackets in plastic hinge zone
    Ding, Yi
    Zeng, Bin
    Zhou, Zhen
    Wei, Yang
    Zhu, Meng
    JOURNAL OF BUILDING ENGINEERING, 2024, 84
  • [6] Seismic performance of circular RC columns retrofitted with prefabricated steel wrapping jackets
    Choi, Eunsoo
    Chung, Young-Soo
    Park, Cheolwoo
    Kim, Dong Joo
    MAGAZINE OF CONCRETE RESEARCH, 2013, 65 (23) : 1429 - 1440
  • [7] Strengthening of eccentrically loaded RC columns using NSM steel and GFRP bars confined with CFRP sheets
    Al-Thairy H.
    Al-Shimarry N.A.
    Journal of Building Pathology and Rehabilitation, 2023, 8 (2)
  • [8] Seismic retrofit of RC circular columns using prefabricated composite jacketing
    Xiao, Y
    Ma, R
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1997, 123 (10): : 1357 - 1364
  • [9] Seismic retrofit of RC circular columns using prefabricated composite jacketing
    Yan Xiao
    Rui Ma
    Journal of structural engineering New York, N.Y., 1997, 123 (10): : 1357 - 1364
  • [10] Retrofit of reinforced concrete columns using partially stiffened steel jackets
    Xiao, Y
    Wu, H
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2003, 129 (06): : 725 - 732