Do all ceramic and composite CAD-CAM materials exhibit equal bonding properties to implant Ti-base materials? An Interfacial Fracture Toughness Study

被引:0
|
作者
Karevan, Yousef [1 ]
Eldafrawy, Maher [1 ]
Herman, Raphael [1 ]
Sanchez, Christelle [1 ,2 ,3 ]
Sadoun, Michael
Mainjot, Amelie [1 ,2 ]
机构
[1] Univ Liege ULiege, Inst Dent, Dent Biomat Res Unit d BRU, 45 Quai G Kurth, B-4020 Liege, Belgium
[2] Univ Liege Hosp CHU, Inst Dent, Dept Fixed Prosthodont, 45 Quai G Kurth, B-4020 Liege, Belgium
[3] MaJEB sprl, Liege, Belgium
关键词
Dental materials; Prosthetic dentistry; Fracture mechanics; Hybrid ceramics; Adhesion; Cementation; Implant prostheses; STRESS-DISTRIBUTION; SURFACE TREATMENTS; REMOVAL FORCES; RESIN CEMENT; ZIRCONIA; STRENGTH; CROWNS; ADHESION; ABUTMENT; TOOTH;
D O I
10.1016/j.dental.2024.07.014
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To compare the interfacial fracture toughness (IFT) with or without aging, of four different classes of CAD-CAM ceramic and composite materials bonded with self-adhesive resin cement to titanium alloy characteristic of implant abutments. Methods: High translucent zirconia (Katana; KAT), lithium disilicate-based glass-ceramic (IPS. emax.CAD; EMX), polymer-infiltrated ceramic network material (PICN) (Vita Enamic; ENA), and dispersed filler composite (Cerasmart 270; CER) were cut into equilateral triangular prisms and bonded to titanium prisms with identical dimensions using Panavia SA Cement Universal. The surfaces were pretreated following the manufacturers' recommendations and developed interfacial area ratio (Sdr) of the pretreated surfaces was measured. IFT was determined using the Notchless Triangular Prism test in a water bath at 36 degrees C before and after thermocycling (10,000 cycles) (n = 40 samples/material). Results: IFT of the materials ranged from 0.80 +/- 0.25 to 1.10 +/- 0.21 MPa.m(1/2) before thermocycling and from 0.71 +/- 0.24 to 1.02 +/- 0.25 MPa.m(1/2) after thermocycling. There was a statistical difference between IFT of CER and the two top performers in each scenario: KAT and EMX before aging, and KAT and ENA after aging. Thermocycling significantly decreased IFT of EMX. The Weibull modulus of IFT was similar for all materials and remained so after thermocycling. Sdr measurements revealed that ENA (7.60)>Ti (4.97)>CER (2.85)>KAT (1.09)=EMX (0.96). Significance: Dispersed filler CAD-CAM composite showed lower performance than the other materials. Aging only affected IFT of Li-Si glass-ceramic, whereas zirconia and PICN performed equally well, probably due to their chemical bonding potential and surface roughness respectively.
引用
收藏
页码:1524 / 1533
页数:10
相关论文
共 7 条
  • [1] Silane influence on bonding to CAD-CAM composites: An interfacial fracture toughness study
    Eldafrawy, Maher
    Greimers, Laura
    Bekaert, Sandrine
    Gailly, Patrick
    Lenaerts, Cedric
    Nguyen, Jean-Francois
    Sadoun, Michael
    Mainjot, Amelie
    DENTAL MATERIALS, 2019, 35 (09) : 1279 - 1290
  • [2] Bonding between implant attachment pickup materials and CAD-CAM denture base material
    Panittaveekul, Meenarin
    Phasuk, Kamolphob
    Levon, John
    Chu, Tien-Min G.
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 126 (01): : 102.e1 - 102.e7
  • [3] Influence of different surface treatment on bonding of metal and ceramic Orthodontic Brackets to CAD-CAM all ceramic materials
    Haralur, Satheesh B.
    Alqahtani, Abdulrahman Mushabbab
    Shiban, Abdullah Saeed
    Alattaf, Zyad Muhammed
    Chaturvedi, Saurabh
    AlQahtani, Saeed M.
    Alqahtani, Nasser M.
    BMC ORAL HEALTH, 2023, 23 (01)
  • [4] Influence of different surface treatment on bonding of metal and ceramic Orthodontic Brackets to CAD-CAM all ceramic materials
    Satheesh B. Haralur
    Abdulrahman Mushabbab Alqahtani
    Abdullah Saeed Shiban
    Zyad Muhammed Alattaf
    Saurabh Chaturvedi
    Saeed M AlQahtani
    Nasser M Alqahtani
    BMC Oral Health, 23
  • [5] Fracture Resistance of Molar Crowns Fabricated with Monolithic All-Ceramic CAD/CAM Materials Cemented on Titanium Abutments: An In Vitro Study
    Dogan, Derya Ozdemir
    Gorler, Oguzhan
    Mutaf, Burcu
    Ozcan, Mutlu
    Eyuboglu, Gunes Bulut
    Ulgey, Melih
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2017, 26 (04): : 309 - 314
  • [6] Effect of denture cleansers on the physical and mechanical properties of CAD-CAM milled and 3D printed denture base materials: An in vitro study
    Hanno, Kenda I.
    Abdul-Monem, Mohamed M.
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (05): : 798.e1 - 798.e8
  • [7] Retentive Strength of CAD/CAM-Fabricated All-Ceramic Crowns Luted on Titanium Implant Abutments Using Different Ceramic Materials and Luting Agents: An In Vitro Study
    Bjelopavlovic, Monika
    Weyhrauch, Michael
    Scheller, Herbert
    Wentaschek, Stefan
    Lehmann, Karl Martin
    MATERIALS, 2022, 15 (19)