Palatal vault configuration and its influence on intraoral scan time and accuracy in completely edentulous arches: a prospective clinical study

被引:0
|
作者
Elawady, Dina Mohamed Ahmed [1 ]
Ibrahim, Wafaa Ibrahim [2 ]
Ghanem, Radwa Gamal [3 ]
Osman, Reham Bassuni [4 ]
机构
[1] MSA Univ, Fac Dent, Dept Prosthodont, Giza, Egypt
[2] Delta Univ Sci & Technol, Fac Oral & Dent Med, Dept Prosthodont, Dakahlia, Egypt
[3] Ahram Canadian Univ, Fac Dent, Dept Prosthodont, Giza, Egypt
[4] Cairo Univ, Fac Dent, Dept Prosthodont, 11 El Saraya St Manial Cairo, Giza 12613, Egypt
来源
JOURNAL OF ADVANCED PROSTHODONTICS | 2024年 / 16卷 / 04期
关键词
Flat palatal vault; Deep palatal vault; Moderate palatal vault; Scan accuracy; Scan; time; IMPRESSION;
D O I
10.4047/jap.2024.16.4.201
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. The aim of this prospective clinical study was to compare the influence of palatal vault forms on accuracy and speed of intraoral (IO) scans in completely edentulous cases. MATERIALS AND METHODS. Based on the palatal vault form, participants were divided into three equal groups (n = 10 each); Class I: moderate; Class II: deep; Class III: flat palatal vault. A reference model was created for each patient using polyvinylsiloxane impression material. The poured models were digitized using an extraoral scanner. The resultant data were imported as a solid CAD file into 3D analysis software (GOM Inspect 2018; Gom GmbH, Braunschweig, Germany) and aligned using the software's coordinate system to determine its X, Y, and Z axes. Five digital impressions (DIs) of maxilla were captured for each patient using an intraoral scanner (TRIOS; 3Shape A/S, Copenhagen, Denmark) and the resultant Standard Tessellation Language (STL) scan files served as test models. Trueness was evaluated by calculating arithmetic mean deviation (AMD) of the vault area between reference and test files while precision was evaluated by calculating AMD between captured scans to measure repeatability of scan acquisition. The scan time taken for each participant was also recorded. RESULTS. There was no significant difference in trueness and precision among the groups (P P = .806 and .950, respectively). Average scan time for Class I and III palatal vaults was 1 min 13 seconds and 1 min 37 seconds, respectively, while class II deep palatal vaults showed the highest scan time of 5 mins. CONCLUSION. Palatal vault form in edentulous cases has an influence on scan time. However, it does not have a substantial impact on the accuracy of the acquired scans. [J Adv Prosthodont 2024;16:201-11]
引用
收藏
页码:201 / 211
页数:11
相关论文
共 8 条
  • [1] Does the palatal vault form have an influence on the scan time and accuracy of intraoral scans of completely edentulous arches? An in-vitro study
    Osman, Reham
    Alharbi, Nawal
    JOURNAL OF ADVANCED PROSTHODONTICS, 2022, 14 (05): : 294 - 304
  • [2] Impact of intraoral scanner, scanning strategy, and scanned arch on the scan accuracy of edentulous arches: An in vitro study
    Jamjoom, Faris Z.
    Aldghim, Adhwaa
    Aldibasi, Omar
    Yilmaz, Burak
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (06): : 1218 - 1225
  • [3] Influence of scan technology on the accuracy and speed of intraoral scanning systems for the edentulous maxilla: An in vitro study
    Osman, Reham Bassuni
    Alharbi, Nawal Murshed
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (09): : 821 - 828
  • [4] How palatal vault morphology and screw length influence the accuracy of dynamic computer-guided orthodontic miniscrew insertion. A prospective clinical study
    Brilli, Davide
    Cauli, Isabella
    Cassetta, Michele
    JOURNAL OF DENTISTRY, 2024, 146
  • [5] The Accuracy of Full-Arch Intraoral Optical Impressions (IOS): Clinical Pilot Study of the Influence of the Scan Strategy, Operator, and Intraoral Scanner
    Cordaro, Matteo
    Sailer, Irena
    Zarauz, Cristina
    Liu, Xinran
    Karasan, Duygu
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2023, 36 (06) : 689 - 696
  • [6] Influence of Operator Experience on Scanning Time and Accuracy with Two Different Intraoral Scanners-A Prospective Clinical Trial
    Thomas, Anjali Anna
    Jain, Ravindra Kumar
    TURKISH JOURNAL OF ORTHODONTICS, 2023, 36 (01) : 10 - 14
  • [7] The accuracy of implant placement using a combination of static and dynamic computer-assisted implant surgery in fully edentulous arches: A prospective controlled clinical study
    Lorwicheanrung, Jarungvit
    Mahardawi, Basel
    Arunjaroensuk, Sirida
    Kaboosaya, Boosana
    Mattheos, Nikos
    Pimkhaokham, Atiphan
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (08) : 841 - 853
  • [8] Comparison of postoperative intraoral scan versus cone beam computerised tomography to measure accuracy of guided implant placement-A prospective clinical study
    Skjerven, Henrik
    Olsen-Bergem, Heming
    Ronold, Hans Jacob
    Riis, Ulf H.
    Ellingsen, Jan Eirik
    CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (06) : 531 - 541