Image Follow-Up After Flow Diverter Treatment Using Only Ultra-High Resolution CT Angiography with Model-Based Iterative Reconstruction: A Case Report

被引:0
|
作者
Iwata, Naoki [1 ]
Sakamoto, Makoto [2 ]
Sakou, Toshio [1 ]
Uno, Tetsuji [2 ]
Kurosaki, Masamichi [2 ]
机构
[1] Tottori Univ Hosp, Dept Clin Radiol, Yonago 6838503, Japan
[2] Tottori Univ, Fac Med, Sch Med, Div Neurosurg,Dept Brain & Neurosci, Yonago 6838503, Japan
关键词
CT angiography; flow diverter; model- based iterative reconstruction; ultra-high-resolution CT; PIPELINE EMBOLIZATION DEVICE; INTRACRANIAL ANEURYSMS; ENDOVASCULAR COILING; COMPUTED-TOMOGRAPHY; MULTICENTER; UTILITY;
D O I
10.33160/yam.2024.08.006
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Follow-up examinations using magnetic resonance imaging or digital subtraction angiography are mandatory after flow diverter treatment of cerebral aneurysms. However, flow diverter features metal artifacts on magnetic resonance imaging and ischemic complications with digital subtraction angiography. Ultra-high- resolution computed tomography systems have recently become available in clinical practice. The combined use of ultra-high-resolution computed tomography and a reconstruction technique called model-based iterative reconstruction is expected to replace followup magnetic resonance imaging and digital subtraction angiography of flow diverter placement. Here, we report a case of ultra-high-resolution computed tomography with model-based iterative reconstruction after flow diverter treatment.
引用
收藏
页码:254 / 258
页数:5
相关论文
共 21 条
  • [1] Utility of follow-up ultra-high-resolution CT angiography with model-based iterative reconstruction after flow diverter treatment for cerebral aneurysms
    Iwata, Naoki
    Sakamoto, Makoto
    Sakou, Toshio
    Uno, Tetsuji
    Kurosaki, Masamichi
    RADIOLOGIA MEDICA, 2023, 128 (10): : 1262 - 1270
  • [2] Utility of follow-up ultra-high-resolution CT angiography with model-based iterative reconstruction after flow diverter treatment for cerebral aneurysms ( vol 128 , pg 1262 , 2023)
    Iwata, Naoki
    Sakamoto, Makoto
    Sakou, Toshio
    Uno, Tetsuji
    Kurosaki, Masamichi
    RADIOLOGIA MEDICA, 2024, 129 (11): : 1736 - 1736
  • [3] Quantitative measurements of emphysema in ultra-high resolution computed tomography using model-based iterative reconstruction in comparison to that using hybrid iterative reconstruction
    Muramatsu, Shun
    Sato, Kazuhiro
    Yamashiro, Tsuneo
    Doi, Kunio
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2022, 45 (01) : 115 - 124
  • [4] Quantitative measurements of emphysema in ultra-high resolution computed tomography using model-based iterative reconstruction in comparison to that using hybrid iterative reconstruction
    Shun Muramatsu
    Kazuhiro Sato
    Tsuneo Yamashiro
    Kunio Doi
    Physical and Engineering Sciences in Medicine, 2022, 45 : 115 - 124
  • [5] Feasibility of low-dose CT with model-based iterative image reconstruction in follow-up of patients with testicular cancer
    Murphy, Kevin P.
    Crush, Lee
    O'Neill, Siobhan B.
    Foody, James
    Breen, Micheal
    Brady, Adrian
    Kelly, Paul J.
    Power, Derek G.
    Sweeney, Paul
    Bye, Jackie
    O'Connor, Owen J.
    Maher, Michael M.
    O'Regan, Kevin N.
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2016, 3 : 38 - 45
  • [6] Impact of model-based iterative reconstruction (MBIR) on image quality in cerebral CT angiography before and after intracranial aneurysm treatment
    Hajdu, Steven David
    Daniel, Roy Thomas
    Meuli, Reto Antoine
    Zerlauth, Jean-Baptiste
    Dunet, Vincent
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 102 : 109 - 114
  • [7] Ultra-high-resolution CT of the temporal bone: Comparison between deep learning reconstruction and hybrid and model-based iterative reconstruction
    Beysang, Achille
    Villani, Nicolas
    Boubaker, Fatma
    Puel, Ulysse
    Eliezer, Michael
    Hossu, Gabriela
    Haioun, Karim
    Blum, Alain
    Teixeira, Pedro Augusto Gondim
    Parietti-Winkler, Cecile
    Gillet, Romain
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2024, 105 (06) : 233 - 242
  • [8] Image quality of ct angiography using model-based iterative reconstruction in infants with congenital heart disease: Comparison with filtered back projection and hybrid iterative reconstruction
    Jia, Qianjun
    Zhuang, Jian
    Jiang, Jun
    Li, Jiahua
    Huang, Meiping
    Liang, Changhong
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 86 : 190 - 197
  • [9] Application of low-dose CT combined with model-based iterative reconstruction algorithm in oncologic patients during follow-up: dose reduction and image quality
    Ippolito, Davide
    Maino, Cesare
    Pecorelli, Anna
    Salemi, Ilaria
    Gandola, Davide
    Riva, Luca
    Franzesi, Cammillo Talei
    Sironi, Sandro
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1124):
  • [10] Low Tube Voltage and Iterative Model Reconstruction in Follow-up CT Angiography After Thoracic Endovascular Aortic Repair: Ultra-low Radiation Exposure and Contrast Medium Dose
    Hou, Ping
    Feng, Xiangnan
    Liu, Jie
    Wang, Xiaopeng
    Jiang, Yaojun
    Dong, Leigang
    Gao, Jianbo
    ACADEMIC RADIOLOGY, 2018, 25 (04) : 494 - 501