Thermal Performance Improvement of a Spiral Channel Solar Air Heater: Numerical and Experimental Investigation in the Desert Climate of Gabes Region

被引:2
|
作者
Ben Amara, Walid [1 ]
Bouabidi, Abdallah [1 ,2 ]
Chrigui, Mouldi [1 ]
机构
[1] Univ Gabes, Natl Engn Sch Gabes ENIG, Mech Modeling Energy & Mat M2EM, Gabes 6029, Tunisia
[2] Higher Inst Ind Syst Gabes ISSIG, Omar Ibn El Khattab St, Gabes 6029, Tunisia
关键词
solar air heater (SAH); spiral channel; CFD; thermal efficiency; horizontal baffles; DO radiation model; absorber; collector; energy; fluid flow; heating; renewable; simulation; TRANSFER ENHANCEMENT; EXERGY ANALYSIS; HYDRAULIC PERFORMANCE; EXPERIMENTAL ENERGY; PLATE; FLAT; OBSTACLES; STORAGE; DUCT; FLOW;
D O I
10.1115/1.4063857
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This study focuses on improving the thermal performance of a solar air heater (SAH) using a single-pass spiral-shaped ducts. The SAH is designed and tested under prevailing weather conditions of Gabes, Tunisia (33 degrees 52.8876 ' N,10 degrees 5.892 ' E). The experimental measurements are carried out over 4 days. Similarly, a computational fluid dynamics (CFD) model was developed to study the fluid flow and the heat transfer inside the SAH using the commercial software ansys fluent 2021 R1". The discrete ordinate (DO) radiation model and the k-omega shear stress transport (SST) turbulence model are used to study the radiative heat transfer and the turbulent flow in the SAH, respectively. The numerical model is validated against experimental data, and the average error does not exceed 3.6%. To improve the heat transfer phenomena, the ratio of horizontal baffle spacing "d" to vertical baffle spacing "p" (d/p) is numerically investigated. Moreover, the highest air outlet temperature during the test days reached 81.1 degrees C under a mass flowrate of 0.0077 kg/s. The maximum efficiencies are 57%, 54%, 49%, and 46% for the configurations d/p = 1.5, d/p = 2, d/p = 1, and d/p = 0.5 under a mass flowrate of 0.02 kg/s, respectively. The SAH design with d/p = 1.5 is about 4-10% more efficient than the standard design with d/p = 1 under a mass flowrate ranging from 0.0077 kg/s to 0.025 kg/s.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Experimental Investigation of Thermal Performance of Improvement a Solar Air Heater With Metallic Fiber
    Mohammed, Mohammed Fowzi
    Eleiwi, Muhammad Asmail
    Kamil, Kamil Talib
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2021, 43 (18) : 2319 - 2338
  • [2] Experimental and numerical investigation of thermal performance in solar air heater with conical surface
    Abuska, Mesut
    Kayapunar, Arif
    HEAT AND MASS TRANSFER, 2021, 57 (11) : 1791 - 1806
  • [3] Experimental and numerical investigation of thermal performance in solar air heater with conical surface
    Mesut Abuşka
    Arif Kayapunar
    Heat and Mass Transfer, 2021, 57 : 1791 - 1806
  • [4] Overall efficiency improvement of photovoltaic-thermal air collector: numerical and experimental investigation in the desert climate of Ouargla region
    Khenfer, Naoui
    Dokkar, Boubekeur
    Messaoudi, Mohamed Taher
    INTERNATIONAL JOURNAL OF ENERGY AND ENVIRONMENTAL ENGINEERING, 2020, 11 (04) : 497 - 516
  • [5] Overall efficiency improvement of photovoltaic-thermal air collector: numerical and experimental investigation in the desert climate of Ouargla region
    Naoui Khenfer
    Boubekeur Dokkar
    Mohamed Taher Messaoudi
    International Journal of Energy and Environmental Engineering, 2020, 11 : 497 - 516
  • [6] Experimental study on the performance of spiral solar air heater
    Jia, Binguang
    Liu, Fang
    Wang, Da
    SOLAR ENERGY, 2019, 182 : 16 - 21
  • [7] Influence on thermal performance of spiral solar air heater with longitudinal baffles
    Jia, Binguang
    Liu, Fang
    Li, Xiao
    Qu, Andi
    Cai, Qingfeng
    SOLAR ENERGY, 2021, 225 : 969 - 977
  • [8] Numerical investigation of thermal performance factor in dimpled-solar air heater (SAH)
    Siddique W.
    Raheem A.
    Ali N.
    Salameh T.
    Waheed K.
    Haq I.U.
    Qureshi K.
    Akram M.S.
    International Journal of Ambient Energy, 2024, 45 (01)
  • [9] Experimental Study of Thermal Hydraulic Performance Improvement in Solar Air Heater Channel With V-Shaped Porous Baffles
    Barman, Priyanka
    Chakraborty, Pritam
    Bhaumik, Rhea
    Bhaumik, Sukesh R.
    Moummi, N.
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2023, 15 (11)
  • [10] THERMAL PERFORMANCE IMPROVEMENT OF ARTIFICIALLY ROUGHENED SOLAR AIR HEATER
    Bader, Nabaa M.
    Mushatet, Khudheyer S.
    ENGINEERING REVIEW, 2023, 43 (01) : 66 - 81