Investigation of reciprocal rank method for automatic generation control in two-area interconnected power system

被引:5
|
作者
Meena, V. P. [1 ]
Singh, V. P. [2 ]
Guerrero, Josep M. [3 ]
机构
[1] Amrita Vishwa Vidyapeetham, Amrita Sch Engn, Dept Elect & Elect Engn, Bengaluru 560035, Karnataka, India
[2] Malaviya Natl Inst Technol, Dept Elect Engn, Jaipur 302017, Rajasthan, India
[3] Aalborg Univ, Ctr Res Microgrids CROM, AAU Energy, DK-9220 Aalborg, Denmark
关键词
Automatic generation control; Jaya optimization; Design of control; Two-area power system; PID controller; Reciprocal rank method; DESIGN; AGC; OPTIMIZATION; ALGORITHM; SEARCH; HYBRID;
D O I
10.1016/j.matcom.2024.06.007
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In this article, the design and performance analysis of Jaya-assisted reciprocal rank-based proportional-integral-derivative controller with derivative filter (PIDn) is proposed for the automatic generation control (AGC) problem of two-area interconnected power systems. The filter with a derivative gain is used to nullify the impact of noise in the input signal. The integral of time multiplied square error (ITSE) of frequency deviations, tie-line power deviations, and area-control errors is the foundation of the goal function developed for tuning controller parameters (ACEs). A single overall objective function is created by combining these subobjectives. ITSEs of two areas, ITSEs of tie-line power deviation, and ITSEs of ACEs of two areas are weighted and summarized to form the overall goal function. Each sub -relative goal's importance in the control design is evaluated using the weights in the overall objective function. The weights in this article are determined using the reciprocal rank approach in a methodical manner, in contrast to earlier techniques where weights were either assumed equally by ignoring the relative relevance of sub -objectives or chosen at random. The resultant total objective function is minimized using the Jaya method. Six different test cases involving various load disturbances in the interconnected areas are used to evaluate the performance of the suggested Jaya optimizer-assisted reciprocal rank technique-based controller. Additionally, the performance of various controllers tuned with the sine cosine algorithm (SCA), salp swarm algorithm (SSA), symbiotic organisms search (SOS), Nelder-Mead simplex (NMS), and Luus- Jaakkola (LJ) algorithms is compared with that of the Jaya-tuned controller. The time domain specifications are provided for each of the six test scenarios. To display the differences in frequencies and tie-line power, the results are also shown. Statistical analysis is also provided to assess the suggested controller's overall efficacy.
引用
收藏
页码:760 / 778
页数:19
相关论文
共 50 条
  • [1] An EID Load Frequency Control Method for Two-Area Interconnected Power System with Photovoltaic Generation
    Yang, Minghui
    Wang, Chunsheng
    Liu, Zijian
    He, Shuhang
    PROCEEDINGS OF THE 33RD CHINESE CONTROL AND DECISION CONFERENCE (CCDC 2021), 2021, : 5662 - 5666
  • [2] Rank Exponent Method Based Optimal Control of AGC for Two-Area Interconnected Power Systems
    Mamta
    Singh, V. P.
    Waghmare, Akanksha V.
    Meena, Veerpratap P.
    Benedetto, Francesco
    Varshney, Tarun
    IEEE ACCESS, 2024, 12 : 35571 - 35585
  • [3] Decentralized Robust Control for Two-Area Interconnected Power System
    Wang, Wei
    Ohmori, Hiromitsu
    2015 AMERICAN CONTROL CONFERENCE (ACC), 2015, : 3656 - 3663
  • [4] Fuzzy-PID Controller Optimized TLBO Algorithm on Automatic Generation Control of a two-area Interconnected Power System
    Nayak, Jyoti Ranjan
    Pati, Tridipta Kumar
    Sahu, Binod Kumar
    Kar, Sanjeeb Kumar
    2015 INTERNATIONAL CONFERENCED ON CIRCUITS, POWER AND COMPUTING TECHNOLOGIES (ICCPCT-2015), 2015,
  • [5] Fuzzy Gain Scheduling Controllers for Automatic Generation Control of Two-area Interconnected Electrical Power Systems
    Arya, Yogendra
    Kumar, Narendra
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2016, 44 (07) : 737 - 751
  • [6] Distributed Model Predictive Control for Two-area Interconnected Power System
    An Aimin
    Lin Jian
    Cheng Chi
    Zhu Wenpei
    2018 INTERNATIONAL CONFERENCE OF GREEN BUILDINGS AND ENVIRONMENTAL MANAGEMENT (GBEM 2018), 2018, 186
  • [7] Decentralized load frequency control for two-area interconnected power system
    Wei WANG
    Hiromitsu OHMORI
    ControlTheoryandTechnology, 2015, 13 (02) : 101 - 114
  • [8] Decentralized load frequency control for two-area interconnected power system
    Wang W.
    Ohmori H.
    Control Theory and Technology, 2015, 13 (02) : 101 - 114
  • [9] Application of TLBO Algorithm to Study the Performance of Automatic Generation Control of a Two-Area Multi-Units Interconnected Power System
    Pati, Tridipta Kumar
    Nayak, Jyoti Ranjan
    Sahu, Binod Kumar
    2015 IEEE INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING, INFORMATICS, COMMUNICATION AND ENERGY SYSTEMS (SPICES), 2015,
  • [10] Grey wolf optimizer-assisted R-method-based weighted minimization for automatic generation control in two-area interconnected power system
    P. J. Krishna
    V. P. Meena
    N. Patnana
    A. Mathur
    V. P. Singh
    International Journal of Dynamics and Control, 2023, 11 : 1779 - 1796