Shear Behavior of Non-Stirrup Ultra-High-Performance Concrete Beams: Contribution of Steel Fibers and UHPC

被引:0
|
作者
Deng, Bowen [1 ]
Zhang, Lifeng [1 ]
Wu, Shengze [1 ]
Jiang, Haibo [1 ]
Tian, Yueqiang [2 ]
Fang, Junfa [3 ]
Zhou, Chengan [1 ]
机构
[1] Guangdong Univ Technol, Sch Civil & Transportat Engn, Guangzhou 510006, Peoples R China
[2] Zhonglu Xincai Guangzhou Technol Co Ltd, Guangzhou 511430, Peoples R China
[3] Zhonglu Dura Int Engn Co Ltd, Guangzhou 510430, Peoples R China
基金
中国国家自然科学基金;
关键词
shear behavior; ultra-high-performance concrete (UHPC); non-stirrup UHPC beams; steel fiber volume content; shear span-to-effective-depth; REACTIVE POWDER CONCRETE; STRENGTH;
D O I
10.3390/buildings14092705
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The shear stirrups and bend-up reinforcement in ultra-high-performance concrete (UHPC) beams could potentially be excluded due to the superior mechanical properties of UHPC. This paper reports the new findings of an experimental research into the factors that influence the shear behavior of non-stirrup UHPC beams. Fourteen beams were tested in shear, comprising twelve non-stirrup UHPC beams and two normal concrete (NC) beams reinforced with stirrups. The test variables included the steel fiber volume content (2.0%, 1.5%, and 0%), the shear span-to-effective-depth ratio (1.2, 1.8, 2.0, and 3.1), beam width (150 mm and 200 mm), and beam height (300 mm, 350 mm, and 400 mm). The results demonstrated that the steel fiber volume content had a significant influence on the shear behavior of the non-stirrup UHPC beams. The failure modes of the beams without steel fibers were typically brittle, whereas those reinforced with steel fibers exhibited ductile failure. The shear resistance of the beams could be significantly enhanced by the addition of steel fibers in the concrete mix. Furthermore, the post-cracking load-bearing performance of the beams could also be markedly improved by the addition of steel fibers. In addition, the shear span-to-effective-depth ratio had a considerable impact on the failure mode and the ultimate shear strength of the tested beams. The contribution of steel fibers to the shear capacity of the UHPC beams was observed to increase as the shear span-to-effective-depth ratio increased. The French standard formulae tended to overestimate the contribution of steel fibers, and the calculation results were found to be more accurate for UHPC beams with a moderate shear span-to-effective-depth ratio (around 2.0). Moreover, the French standard formulae demonstrated greater accuracy at a larger beam height for calculating the contribution of UHPC matrix.
引用
收藏
页数:32
相关论文
共 50 条
  • [1] Experimental Study on Shear Behavior of Non-Stirrup Ultra-High Performance Concrete Beams
    Li, Pingjie
    Cheng, Quan
    Chen, Nanxun
    Tian, Yueqiang
    Fang, Junfa
    Jiang, Haibo
    MATERIALS, 2023, 16 (11)
  • [2] Effectiveness and response of replacing web reinforcements with steel fibers reinforced in shear for non-stirrup UHPC beams
    Xu, Qizhi
    Zhu, Yutong
    Wang, Jingquan
    Sebastian, Wendel
    ENGINEERING STRUCTURES, 2023, 288
  • [3] Shear behavior of ultra-high-performance concrete (UHPC) beams that replace the stirrups with externally web-bonded steel plates
    Li, Lifeng
    Jin, Weimeng
    Ye, Meng
    Tang, Jiahao
    Hou, Miao
    ENGINEERING STRUCTURES, 2025, 332
  • [4] Structural performance of ultra-high-performance concrete beams with different steel fibers
    Yoo, Doo-Yeol
    Yoon, Young-Soo
    ENGINEERING STRUCTURES, 2015, 102 : 409 - 423
  • [5] Experimental Investigation on Shear Behavior of Non-Stirrup UHPC Beams under Larger Shear Span-Depth Ratios
    Zhang, Lifeng
    Deng, Bowen
    He, Beini
    Jiang, Haibo
    Xiao, Jie
    Tian, Yueqiang
    Fang, Junfa
    BUILDINGS, 2024, 14 (05)
  • [6] Flexural behavior of ultra-high-performance concrete (UHPC) encased concrete-filled steel tubular (CFST) beams
    Yang, Yuxing
    Huang, Xuankai
    Liao, Feiyu
    Chen, Yufeng
    Lin, Qiuhui
    Wang, Ying
    STRUCTURES, 2024, 69
  • [7] Shear behavior of externally prestressed ultra-high-performance concrete (UHPC) T-beams without stirrups
    Ye, Meng
    Li, Lifeng
    Pei, Bida
    Yoo, Doo-Yeol
    Li, Huihui
    ENGINEERING STRUCTURES, 2023, 288
  • [8] Numerical Study of the Shear Behavior of Ultra-High-Performance Concrete Beams
    Martinez-de la Concha, Antonio
    Rios, Jose David
    Cifuentes, Hector
    HORMIGON Y ACERO, 2024, 75 (302): : 157 - 162
  • [9] Shear Behavior of Ultra-High-Performance Concrete Beams Reinforced with High-Strength Steel Bars
    Ahmad, S.
    Bahij, S.
    Al-Osta, M. A.
    Adekunle, S. K.
    Al-Dulaijan, S. U.
    ACI STRUCTURAL JOURNAL, 2019, 116 (04) : 3 - 14
  • [10] Shear Behavior of Ultra-High-Performance Concrete Beams Reinforced with High-Strength Steel Bars
    Zhang, Xiaoya
    Chen, Shiming
    ACI STRUCTURAL JOURNAL, 2020, 117 (03) : 323 - 323