Daylighting and energy performance of window with transparent insulation slats combined with building shading in the hot-summer and cold-winter zone

被引:1
|
作者
Li, Qingsong [1 ,2 ,3 ]
Zhang, Ling [1 ,2 ,3 ]
Wang, Xuchao [1 ,2 ,3 ]
Su, Xiaosong [1 ,2 ,3 ]
机构
[1] Hunan Univ, Coll Civil Engn, Changsha 410082, Hunan, Peoples R China
[2] Hunan Univ, Natl Ctr Int Res Collaborat Bldg Safety & Environm, Changsha 410082, Peoples R China
[3] Hunan Univ, Key Lab Bldg Safety & Energy Efficiency, Minist Educ, Changsha 410082, Peoples R China
基金
中国国家自然科学基金;
关键词
Transparent insulation slats; Energy and daylighting performance; Building shading effects; Energy efficient; DOUBLE-SKIN FACADE; THERMAL PERFORMANCE; FENESTRATION; MICROCLIMATE; SAVINGS; SYSTEM;
D O I
10.1016/j.scs.2024.105772
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The shading from surrounding buildings significantly affects the energy and daylighting performance of transparent insulation materials (TIM) systems. In previous studies, the performance of TIM systems was primarily discussed in ideal situations without considering the influence of surrounding buildings. However, this is not realistic in actual urban scenarios. This study presents a case study conducted in Changsha to evaluate and compare the energy and daylighting performance of the window with transparent insulation slats (WTIS) and normal double glazing (NDG). The study considers the varying degrees of building shading effects. The results show that windows facing west exhibit the best energy efficiency, while windows facing south have the worst. WTIS achieves a higher Useful Daylight Illuminance (UDI) when building shading effects are not significant, whereas NDG achieves a higher UDI when building shading effects are significant. Despite increasing lighting energy consumption by 69.8 % to 84.3 %, WTIS consistently outperforms NDG in terms of total energy savings. Furthermore, strategically utilizing or deactivating WTIS according to recommended periods during winter can enhance the total solar gain for the building by approximately 22.3 %. This study provides valuable recommendations for the application of WTIS systems and the design of buildings in the hot-summer and cold-winter zone.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Energy and Economic Performance of Solar Cooling Systems in the Hot-Summer and Cold-Winter Zone
    Huang, Li
    Zheng, Rongyue
    BUILDINGS, 2018, 8 (03)
  • [2] ANALYSIS OF THE ECONOMICAL THICKNESS OF THERMAL INSULATION LAYER OF THE BUILDING ENVELOPE IN THE HOT-SUMMER AND COLD-WINTER ZONE
    Guo, Yonghui
    Zhang, Guoqiang
    Zhou, Jin
    Xie, Mingjing
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 1455 - 1463
  • [3] Energy-saving Strategy of Building Skins System in Hot-summer and Cold-winter Zone
    Wang, Chongjie
    Zhang, Hong
    Tang, Bing
    Li, Jie
    PROCEEDINGS OF THE 2018 3RD INTERNATIONAL CONFERENCE ON MODELLING, SIMULATION AND APPLIED MATHEMATICS (MSAM 2018), 2018, 160 : 298 - 300
  • [4] Experimental Assessment of the Energy Performance of a Double-Skin Semi-Transparent PV Window in the Hot-Summer and Cold-Winter Zone of China
    Wang, Wei
    Zhang, Wei
    Xie, Lingzhi
    Wu, Yupeng
    Tian, Hao
    Zheng, Lin
    ENERGIES, 2018, 11 (07):
  • [5] Daylighting and energy performance of the window with transparent insulation slats in the humid subtropical climate zone
    Wang, Xuchao
    Zhang, Ling
    Su, Xiaosong
    Yang, Huixian
    ENERGY AND BUILDINGS, 2023, 300
  • [6] The solution of building energy-saving strategy in the hot-summer and cold-winter area
    Hong, T. (tanghong969@126.com), 1600, Research India Publications (08):
  • [7] Research on Climate Adaptability of Energy Conservation Building with Renewable Energy Sources in Hot-summer and Cold-winter Zone of China
    Hui Zhang
    Zhuang Yu
    RENEWABLE ENERGY AND ENVIRONMENTAL TECHNOLOGY, PTS 1-6, 2014, 448-453 : 1289 - 1296
  • [8] A comparative research on energy efficiency of atrium morphological types in hot-summer and cold-winter zone
    Bing, Xia
    Jiaqi, Wang
    IPPTA: Quarterly Journal of Indian Pulp and Paper Technical Association, 2018, 30 (04) : 165 - 178
  • [9] Thermal performance of a novel solar thermal facade system in a hot-summer and cold-winter zone
    A, Yongga
    Li, Nianping
    Long, Jibo
    He, Yingdong
    SOLAR ENERGY, 2020, 204 (204) : 106 - 114
  • [10] Study on Daylighting and Energy Conservation Design of Transparent Envelope for office building in Hot Summer and Cold Winter Zone
    Yu, Jinghua
    Liu, Yu
    Xiong, Chao
    Huang, Jun Chao
    9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 1642 - 1649