MECHANICAL BEHAVIOR ANALYSIS OF A FUNCTIONALLY GRADED POROUS DENTAL IMPLANT

被引:0
|
作者
Dabaja, Rana [1 ]
Khan, Abdul Sayeed [2 ]
Banu, Mihaela [1 ]
机构
[1] Univ Michigan, Dept Mech Engn, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Naval Architecture & Marine Engn, Ann Arbor, MI 48109 USA
关键词
TPMS solid gyroid; dental implant; Ti-6Al-4V; functionally graded materials; selective laser melting; titanium; TITANIUM; BONE; SCAFFOLDS;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Medically compromised patients causing severe amounts of bone loss in the maxillary/mandibula experience low success rates with dental implants. The bone loss is caused by a weak interfacial connection between the implant and the maxillary/mandibula and because of a stiffness mismatch between bone and titanium. To address this challenge, functionally graded porous dental implants are proposed as a promising solution to mimic the natural tooth by matching the stiffness of the titanium support with the maxillary/mandibula. In this paper, we employed functionally graded materials to design a triply periodic minimal surface (TPMS) gyroid-graded porous structure with five distinct connected porosities leading to a solid core. The study aimed to develop a structure with mechanical properties similar to bone while maintaining mechanical strength to withstand physiological loading. An analytical model for a functionally graded porous structure was utilized to calculate a theoretical elastic modulus in relation to five different porosities along the gradient. The target porosities were determined as 10%, 20%, 30%, 40%, and 50%, with corresponding elastic modulus ranging from 103.94 GPa to 35.25 GPa. Five TPMS solid gyroid samples made of Ti-6Al-4V were designed for a specific stiffness corresponding to the bone, using an analytical model considering an exponential relationship between stiffness and porosity. These structures were then manufactured through selective laser melting, resulting in final porosities of 6.64%, 11.56%, 18.40%, 28.74%, and 36.23%, with corresponding pore sizes of 130 mu m, 185 mu m, 280 mu m, 360 mu m, and 420 mu m. The stiffness of the designed and manufactured porous structures was validated through uniaxial compressive experiments. Digital Image Correlation (DIC) accurately recorded displacements to calculate strain during compression experiments up to failure. Microscopic analysis of the compression samples' failure provided insights into the role of pores in sample damage. Results confirmed that the elastic modulus of the porous structures was reduced to the designed values between 21.7-65.3 GPa, compatible with bone. This represents a significant drop in stiffness compared to solid Ti6Al-4V, for which stiffness is 114 GPa. Through this matching of stiffness between bone and the implant, the so-called stress shielding effect caused by a weak interfacial connection can be reduced, decreasing the risk of implant failure.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] DESIGN AND MANUFACTURING OF A FUNCTIONALLY GRADED POROUS DENTAL IMPLANT
    Dabaja, Rana
    Popa, Bogdan I.
    Bak, Sun-Yung
    Mendonca, Gustavo
    Banu, Mihaela
    PROCEEDINGS OF ASME 2022 17TH INTERNATIONAL MANUFACTURING SCIENCE AND ENGINEERING CONFERENCE, MSEC2022, VOL 1, 2022,
  • [2] Mechanical Behavior of Porous Functionally Graded Nanocomposite Materials
    Mota, A. F.
    Loja, M. A. R.
    C-JOURNAL OF CARBON RESEARCH, 2019, 5 (02):
  • [3] Design optimization of functionally graded dental implant
    Hedia, HS
    Mahmoud, NA
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2004, 14 (02) : 133 - 143
  • [4] Fabrication and properties of functionally graded dental implant
    Watari, F
    Yokoyama, A
    Saso, F
    Uo, M
    Kawasaki, T
    COMPOSITES PART B-ENGINEERING, 1997, 28 (1-2) : 5 - 11
  • [5] Fabrication and properties of functionally graded dental implant
    Hokkaido Univ, Sapporo, Japan
    Compos Part B:Eng, 1-2 (5-11):
  • [6] Effect of porous defects on mechanical behavior of functionally graded materials
    Nadiia, Dergachova
    Jia, Qu
    JOURNAL OF STRAIN ANALYSIS FOR ENGINEERING DESIGN, 2025, 60 (02): : 106 - 116
  • [7] Mechanical Analysis of Functionally Graded Porous Structures: A Review
    Wu, Helong
    Yang, Jie
    Kitipornchai, Sritawat
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2020, 20 (13)
  • [8] Design optimization of a radial functionally graded dental implant
    Ichim, Paul I.
    Hu, Xiaozhi
    Bazen, Jennifer J.
    Yi, Wei
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2016, 104 (01) : 58 - 66
  • [9] Finite element stress analysis of functionally graded dental implant of a premolar tooth
    Jalali, S. Kamal
    Yarmohammadi, Reza
    Maghsoudi, Fatemeh
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2016, 30 (11) : 4919 - 4923
  • [10] Finite element stress analysis of functionally graded dental implant of a premolar tooth
    S. Kamal Jalali
    Reza Yarmohammadi
    Fatemeh Maghsoudi