Full-scale car fire tests on FRP reinforced RC columns in piloti structures

被引:0
|
作者
Choi, In-Rak [1 ]
Park, Ji-Hye [2 ]
Min, Jeong-Ki [3 ]
Shin, Jinwon [4 ]
Choi, Sungmo [5 ]
机构
[1] Hoseo Univ, Div Architecture & Civil Engn, Asan, South Korea
[2] Univ Seoul, Dept Architectural Engn, Seoul, South Korea
[3] Korea Conform Labs, Samcheok, South Korea
[4] Catholic Kwandong Univ, Dept Architectural Engn, Kangnung, South Korea
[5] Univ Seoul, Dept Architectural Engn, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
Automobile testing - Automobiles - Concrete slabs - Explosions - Fiber reinforced concrete - Fires - Flammability testing - Ignition - Premixed flames;
D O I
10.1016/j.firesaf.2024.104248
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Car fire tests were conducted on fiber reinforced polymer (FRP) reinforced columns to evaluate the fire effects on piloti structures. The study involved a mid-size car (1,998 cc) with fuel and tire air pressure removed to reduce the risk of explosion. The objectives were to measure the heat release rate (HRR) and temperature distributions during the fire and to evaluate the fire behavior of the columns in the piloti structure. Results from the car combustion test showed a total heat release of 5,210 MJ, with a maximum temperature of 455.0 degrees C at 2.5m height above the car ceiling and an internal temperature of 1025.7 degrees C near the ignition point at the car seat. In the piloti structure fire test, consisting of four reinforced concrete (RC) columns with and without FRP reinforcement and a roof slab, the maximum temperature reached 728.5 degrees C under the slab. Thicker FRP reinforcement resulted in lower temperatures on the column surface. Fire Dynamics Simulator (FDS) software was used to validate the test results and showed accurate predicted temperatures at 3m (within 10 % error). However, discrepancies were observed at 2.5m (24 % error) and below, although the simulated fire behavior agreed well with the test results for heights of 2.0m and above.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Fire tests on full-scale FRP reinforced concrete slabs
    Hajiloo, Hamzeh
    Green, Mark F.
    Noel, Martin
    Benichou, Noureddine
    Sultan, Mohamed
    COMPOSITE STRUCTURES, 2017, 179 : 705 - 719
  • [2] Structural Evaluation of Full-Scale FRP-Confined Reinforced Concrete Columns
    De Luca, Antonio
    Nardone, Fabio
    Matta, Fabio
    Nanni, Antonio
    Lignola, Gian Piero
    Prota, Andrea
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2011, 15 (01) : 112 - 123
  • [3] Seismic upgrading of RC buildings by FRP: Full-scale tests of a real structure
    Della Corte, Gaetano
    Barecchia, Enrico
    Mazzolani, Federico M.
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2006, 18 (05) : 659 - 669
  • [4] Full-scale fire tests on steel roof truss structures
    Jiang, Shouchao
    Zhu, Shaojun
    Guo, Xiaonong
    Li, Zhiyuan
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 169
  • [5] Full-scale fire tests of RC metro shield TBM tunnel linings
    Yan, Zhi-guo
    Zhu, He-hua
    Ju, J. Woody
    Ding, Wen-qi
    CONSTRUCTION AND BUILDING MATERIALS, 2012, 36 : 484 - 494
  • [6] Analysis of full-scale fire tests
    Auguin, G
    Forestier, BE
    Giovannelli, G
    Casalé, E
    10TH INTERNATIONAL SYMPOSIUM ON AERODYNAMICS AND VENTILATION OF VEHICLE TUNNELS: PRINCIPLES, ANALYSIS AND DESIGN, 2000, (43): : 659 - 669
  • [7] Experimental full-scale car fire study
    Sun, Xuan
    Wang, Wandi
    Li, Yinqing
    Zhao, Kewei
    Hu, Rui
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2010, 50 (07): : 1090 - 1093
  • [8] FULL-SCALE FIRE RESISTANCE TESTING OF CONCRETE BEAMS REINFORCED WITH VARIOUS FRP REINFORCEMENT
    Protchenko, K.
    Urbanski, M.
    ARCHIVES OF CIVIL ENGINEERING, 2020, 66 (04) : 119 - 136
  • [9] Cyclic Behavior of Nonconforming Full-Scale RC Columns
    Di Ludovico, M.
    Verderame, G. M.
    Prota, A.
    Manfredi, G.
    Cosenza, E.
    JOURNAL OF STRUCTURAL ENGINEERING, 2014, 140 (05)
  • [10] Full-scale and reduced-scale tests on smoke movement in case of car park fire
    Horvath, Istvan
    van Beeck, Jeroen
    Merci, Bart
    FIRE SAFETY JOURNAL, 2013, 57 : 35 - 43