Experimental and analytical assessment of the racking behavior of timber frame walls with single-sided double-layered sheathing panels

被引:0
|
作者
Byloos, Dries [1 ]
Vandoren, Bram [1 ]
机构
[1] Hasselt Univ, Fac Engn Technol, Martelarenlaan 42, B-3500 Hasselt, Belgium
关键词
Shear wall diaphragm; Staples; Racking resistance; Eurocode; 5; Double-layered sheathing panel; Gypsum plasterboard; Resinoid-bonded particle board; Experiments; Analytical; SHEAR WALLS; CONNECTIONS; RESISTANCE;
D O I
10.1016/j.engstruct.2024.118592
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In lightweight timber frame buildings, the horizontal stability against, for instance, wind loads is mainly ensured by shear diaphragms. These shear walls are typically constructed using a timber frame and a load- bearing sheathing layer on one or both sides of the framework. An atypical construction method uses double sheathing panels on top of each other, e.g. because of acoustic or fire safety reasons. However, no design rules are provided for such structures: the respective current and upcoming European standard (Eurocode 5 part 1-1) does not consider the structural contribution of both sheathing panel layers. Therefore, in this study, an experimental campaign is performed to enhance the knowledge of such double-sheathed shear walls, and two analytical calculation methods are proposed. The experimental campaign tests eight full-scale configurations through a racking resistance test with monotonic loading. Sheathing materials include load-bearing and non- load-bearing gypsum plasterboards and resinoid-bonded particle boards. All sheathing panels are connected to the fully anchored frames using staples. Results demonstrate that adding a second sheathing layer of the same material, with the same fastener disposition as the inner layer does not fully double the racking capacity and racking stiffness. Secondly, using a non-load-bearing gypsum plate as the inner layer creates a long plateau phase at the post-peak loading response, producing a less brittle failure behavior. The experiments are used as a benchmark to develop an analytical model based on Bla ss and Gebhardt's method for calculating the shear capacity of dowel-type connections with an interlayer. The proposed method introduces an interaction factor that takes into account that the connections of the outer sheathing layer, which pass through the inner sheathing layer, also contribute to the sheathing-to-framing connection of the latter. A simplified model is also presented, using a combination factor that aligns with the current Eurocode 5 design method for walls with sheathing panels on both sides of the framing. Different values for the respective interaction and combination factors are verified to determine a safe value for each tested configuration.
引用
收藏
页数:12
相关论文
共 4 条
  • [1] Splitting capacity of bottom rails in partially anchored timber frame shear walls with double-sided sheathing
    Caprolu, Giuseppe
    Girhammar, Ulf Arne
    Källsner, Bo
    IES Journal Part A: Civil and Structural Engineering, 2015, 8 (01): : 1 - 23
  • [2] Axial compressive behaviour of cold-formed steel single-stud wall panels with one-sided sheathing and two-sided dissimilar sheathing board configurations: Experimental and analytical study
    Sonkar, Chanchal
    McCrum, Daniel P.
    THIN-WALLED STRUCTURES, 2023, 187
  • [3] Behavior of Lightweight Wood-Frame Shear Walls with Plybamboo and Wood Sheathing Panels: Experimental Study, Numerical Simulation, and Parametric Models for the Design Process
    Wu, Ruijia
    Xu, Yongjia
    Hou, Yubing
    Zhang, Xiangfei
    Xiao, Yan
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2025,
  • [4] Axial buckling resistance of cold-formed steel built-up I-section wall panels with single- and double-layer sheathing configurations: experimental and analytical studies
    Sonkar, Chanchal
    Dalbehera, Mickey Mecon
    Chourasia, Ajay
    AUSTRALIAN JOURNAL OF STRUCTURAL ENGINEERING, 2024,