Spontaneous catheter tip migration in Totally Implantable Venous Access Port (TIVAP) to right atrium

被引:0
|
作者
Wetan, Ni Gusti A. A. Manik Yuniawaty [1 ]
Irawan, Hendry [1 ]
Adiputra, Putu Anda Tusta [1 ]
机构
[1] Udayana Univ, Prof IGNG Ngoerah Gen Hosp, Dept Surg, Surg Oncol Div, Denpasar, Bali, Indonesia
关键词
TIVAP; Complication; False route; Spontaneous migration; MANAGEMENT;
D O I
10.1016/j.ijscr.2024.110122
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction and importance: The use of a Totally Implantable Venous Access Port (TIVAP) has been a popular access option in chemotherapy for cancer patients, but complications, both long-term and short-term, may arise in the fixation process. This paper discusses the importance of detection and management of complications that arise as a result of TIVAP insertion. Case presentation: A 51-year-old female patient came to the hospital to undergo a TIVAP implantation for her chemotherapy through the right subclavian vein; however, a false route occurred to the right internal jugular vein instead of the right atrium. No direct revision was conducted for this case. Follow-up was conducted for 3 months. The first month post-chemotherapy, the access flow remained smooth. No complications were found. Clinical discussion: The right subclavian vein is preferred for its low complication and high success rates. Typically, a C-Arm is used to guide TIVAP insertion, allowing immediate corrections to prevent complications. In this patient, the C-Arm was unavailable due to logistical constraints. The TIVAP catheter tip was evaluated and sustained. High-velocity flow at the catheter tip can cause a jet effect, potentially shifting the catheter tip cranially or to the proper position in the right atrium. Conclusion: We conclude that TIVAP attachment does not have to be redone when a false route happens, and routine observation on possible complications as well as gradual drug administration should be done instead.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Migration of a fractured totally implantable venous access catheter into the right ventricle
    Barbetakis, Nikolaos
    Asteriou, Christos
    Kleontas, Athanassios
    Karvelas, Christos
    TUBERKULOZ VE TORAK-TUBERCULOSIS AND THORAX, 2011, 59 (01): : 103 - 104
  • [2] Fracture at catheter of totally implantable venous access port with migration into the right pulmonary artery: A serious complication
    Ben Kridis, Wala
    Sahnoun, Mohamed
    Maraoui, Hammadi
    Amari, Naceur
    Frikha, Mounir
    ACTA CLINICA BELGICA, 2016, 71 (05) : 349 - 352
  • [3] Totally implantable venous access systems (PORT): Secondary malposition or spontaneous migration
    Milanesi, E
    Capello, C
    Satolli, MA
    Chiappino, I
    Destefanis, M
    DallaMola, A
    Porcile, GF
    Migliaretti, G
    Martinotti, R
    Sandrucci, S
    ANNALS OF ONCOLOGY, 2000, 11 : 25 - 25
  • [4] Hepatic migration of a catheter fragment followed by disconnection of a totally implantable venous access port
    Wang, C.-S.
    Yang, C.-J.
    Chen, S.-C.
    Chen, H.-C.
    Huang, Ming-Shyan
    International Journal of Artificial Organs, 2008, 31 (12): : 1059 - 1061
  • [5] Hepatic migration of a catheter fragment followed by disconnection of a totally implantable venous access port
    Wang, C. -S.
    Yang, C. -J.
    Chen, S. -C.
    Chen, H. -C.
    Huang, M. -S.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2008, 31 (12): : 1059 - 1061
  • [6] Spontaneous fracture and migration of catheter of a totally implantable venous access port via internal jugular vein - a case report
    Seung Yeon Ko
    Sun Cheol Park
    Jeong Kye Hwang
    Sang Dong Kim
    Journal of Cardiothoracic Surgery, 11
  • [7] Spontaneous fracture and migration of catheter of a totally implantable venous access port via internal jugular vein - a case report
    Ko, Seung Yeon
    Park, Sun Cheol
    Hwang, Jeong Kye
    Kim, Sang Dong
    JOURNAL OF CARDIOTHORACIC SURGERY, 2016, 11
  • [8] Effectiveness of breast fixation to reduce migration of the tip of a totally implantable venous access port in women
    Song, Myung Gyu
    Seo, Tae-Seok
    Kim, Yun Hwan
    Cho, Sung Bum
    Jung, Euichul
    Chung, Hwan Hoon
    Lee, Seung Hwa
    JOURNAL OF VASCULAR ACCESS, 2016, 17 (04): : 348 - 352
  • [9] Femoral placement of a totally implantable venous access port with spontaneous catheter fracture: case report
    Kondo, Tomohiro
    Matsumoto, Shigemi
    Doi, Keitaro
    Nomura, Motoo
    Muto, Manabu
    CVIR ENDOVASCULAR, 2020, 3 (01)
  • [10] Femoral placement of a totally implantable venous access port with spontaneous catheter fracture: case report
    Tomohiro Kondo
    Shigemi Matsumoto
    Keitaro Doi
    Motoo Nomura
    Manabu Muto
    CVIR Endovascular, 3