Universal C-MAC® videolaryngoscope use in adult patients: a single-centre experience

被引:0
|
作者
Penders, R. [1 ]
Kelly, F. E. [1 ]
Cook, T. M. [1 ,2 ]
机构
[1] Royal United Hosp Bath NHS Fdn Trust, Bath, England
[2] Univ Bristol, Sch Med, Bristol, England
关键词
airway; intubation; laryngoscopy; videolaryngoscopy; AIRWAY MANAGEMENT; TRACHEAL INTUBATIONS; 1ST OPTION; EVENTS;
D O I
10.1002/anr3.12314
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Universal use of Storz C-MAC (R) videolaryngoscopes was implemented for adult tracheal intubations in the operating theatres, intensive care unit and emergency department at Royal United Hospitals Bath NHS Foundation Trust in 2017. We report data from 1099 intubations from March 2020 to March 2022, collected contemporaneously and anonymously using a smartphone app, representing an estimated 18% of intubations in operating theatres and 30% of intubations in other locations during this period. Intubation success was 100%. The first-pass success rate was 87.3% overall: 87% with a Macintosh videolaryngoscope, 92% with a hyperangulated videolaryngoscope and 81% for users with <= 20 previous uses. First-pass success without complications was 87% overall: 87% in operating theatres (836/962), 93% in the emergency department (38/41) and 83% in the intensive care unit (73/88). Complications occurred during 0.6% of intubations: 0/962 in operating theatres and 7/137 in non-theatre locations. The rate of complications was unaltered by blade type (Macintosh 5/994 vs. hyperangulated 2/105, p = 0.14); intubator experience with the device (<= 20 previous clinical uses 2/260 vs. > 20 previous uses 5/832, p = 0.67) and use of airborne personal protective equipment (PPE 6/683 vs. no-PPE 1/410, p = 0.27). Complication rates increased outside theatres (theatres 0/963 vs. non-theatre 7/136, p < 0.001) and during rapid sequence induction (RSI 6/379 (1.6%) vs. non-RSI 1/720 (0.1%), p = 0.008).
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Clinical experience with the C-Mac videolaryngoscope in morbidly obese patients
    Gaszynski, Tomasz
    ANAESTHESIOLOGY INTENSIVE THERAPY, 2014, 46 (01) : 14 - 16
  • [2] Current evidence for the use of C-MAC videolaryngoscope in adult airway management: a review of the literature
    Xue, Fu-Shan
    Li, Hui-Xian
    Liu, Ya-Yang
    Yang, Gui-Zhen
    THERAPEUTICS AND CLINICAL RISK MANAGEMENT, 2017, 13 : 831 - 841
  • [3] Randomized controlled trial comparing the McGrath videolaryngoscope with the C-MAC videolaryngoscope in intubating adult patients with potential difficult airways
    Ng, I.
    Hill, A. L.
    Williams, D. L.
    Lee, K.
    Segal, R.
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 109 (03) : 439 - 443
  • [4] The C-MAC videolaryngoscope for prehospital emergency intubation
    Deakin, Charles D.
    EMERGENCY MEDICINE JOURNAL, 2011, 28 (08) : 643 - 643
  • [5] Difficulties using the C-MAC paediatric videolaryngoscope
    Oakes, N. D.
    Dawar, A.
    Murphy, P. C.
    ANAESTHESIA, 2013, 68 (06) : 653 - 654
  • [6] First experience of the use of the C-MAC PM videolaryngoscope in a clinical setting by anesthetic nurses : A comparison with anesthetists
    Kontouli, Z.
    Stroumpoulis, K.
    Halari-Baradaki, E.
    Papadimitriou, L.
    Iacovidou, N.
    Xanthos, T.
    ACTA ANAESTHESIOLOGICA BELGICA, 2013, 64 (04) : 153 - 158
  • [7] Determination of the optimal stylet strategy for the C-MAC® videolaryngoscope
    McElwain, J.
    Malik, M. A.
    Harte, B. H.
    Flynn, N. H.
    Laffey, J. G.
    ANAESTHESIA, 2010, 65 (04) : 369 - 378
  • [8] The use of the C-MAC videolaryngoscope for awake intubation in patients with a predicted extremely difficult airway: case series
    Gaszynski, Tomasz
    THERAPEUTICS AND CLINICAL RISK MANAGEMENT, 2018, 14 : 539 - 542
  • [9] A randomised, crossover comparison of the C-MAC videolaryngoscope with direct laryngoscopy in 100 patients
    Cavus, E.
    Thee, C.
    Doerges, V.
    Moeller, T.
    Wangner, K.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (01) : 264 - 264
  • [10] Combined use of C-MAC® videolaryngoscope and nasal videobronchoscope for critical airway rescue and intubation
    Cormack, J. R.
    Ho, M. L.
    ANAESTHESIA AND INTENSIVE CARE, 2018, 46 (03) : 347 - 348