Simultaneous electrochemical detection of hydroquinone and catechol using a carbon nanotube paste electrode modified with electrochemically polymerized L-alanine

被引:1
|
作者
Manju, Manoj Koorgalli [1 ,2 ]
Manjunatha, Jamballi G. [1 ]
Bhimaraya, Kanathappa [1 ]
Aldossari, Samar A. [3 ]
Mohammad, Saikh [3 ]
Sillanpaa, Mika [4 ]
机构
[1] Mangalore Univ, FMKMC Coll, Constituent Coll, Dept Chem, Madikeri, Karnataka, India
[2] JSS Sci & Technol Univ, Dept Chem, Tech Inst Campus, Mysuru, Karnataka, India
[3] King Saud Univ, Coll Sci, Dept Chem, POB 2455, Riyadh 11451, Saudi Arabia
[4] Aarhus Univ, Dept Biol & Chem Engn, Norrebrogade 44, DK-8000 Aarhus C, Denmark
关键词
Hydroquinone; L-Alanine; Carbon nanotube paste; Electrochemical sensor; Voltammetry; PHENOLIC-COMPOUNDS; RESORCINOL; ACID; DERIVATIVES; EPINEPHRINE; SAMPLES; SENSOR;
D O I
10.1007/s11696-024-03652-7
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
An electrochemical analysis of Hydroquinone (HDQ) and Catechol (CTL) was analyzing in a 0.2 M phosphate buffer solution (PBS) using a modest constructing electrochemically polymerized (EP) L-Alanine (ALN) modified carbon nanotube paste electrode (EP(ALN)MCNTPE). The electrochemical, structural, resistive, and conductive properties of both the EP(ALN)MCNTPE and bare carbon nanotube paste electrode (BCNTPE) surfaces were studied by cyclic voltammetry (CV), Differential pulse voltammetry (DPV), scanning electron microscopy (SEM) and electrochemical impedance Spectroscopy (EIS) techniques. The EP(ALN) presented electrode surface exhibits significantly enhanced peak currents compared to BCNTPE. The optimizing experimental parameters, including PBS in pH, scan rate and concentration variation, also constructed to achieving high selectivity and sensitivity for the analysis of HDQ. The oxidation and reduction peak currents of HDQ exhibited improvement with increasing concentrations ranging from 0.2 mu M to 4.0 mu M. The achieved lower limit of detection (LOD) and lower limit of quantification (LOQ) were 0.174 mu M and 0.582 mu M, alone and it shows good analytical responses. The EP(ALN)MCNTPE shows good stability, reproducibility, and repeatability for HDQ. The electrochemically developed sensor proved applicable for both quantitative and qualitative analysis of HDQ in a cosmetic sample.
引用
收藏
页码:8019 / 8030
页数:12
相关论文
共 50 条
  • [1] Simultaneous Electrochemical Detection of Catechol and Hydroquinone Based on a Carbon Nanotube Paste Electrode Modified with Electro-Reduced Graphene Oxide
    Chen, Tingfei
    Liu, Chao
    Liu, Xiaojun
    Zhu, Chunnan
    Zheng, Dongyun
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2024, 25 (18)
  • [2] Electrochemical detection of hydroquinone and catechol with covalent organic framework modified carbon paste electrode
    Xin, Yu
    Wang, Ning
    Wang, Chunli
    Gao, Wei
    Chen, Mingli
    Liu, Nazhen
    Duan, Jizhou
    Hou, Baorong
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2020, 877
  • [3] Electrochemical detection of catechol with a disposable carbon nanotube paste electrode modified with CTAB
    Chen, Tingfei
    Huang, Yanzhi
    Liu, Xiaojun
    Zhu, Chunnan
    Liu, Chao
    Zheng, Dongyun
    PHYSICA SCRIPTA, 2025, 100 (01)
  • [4] A reliable electrochemical sensor for detection of catechol and hydroquinone at MgO/GO modified carbon paste electrode
    K. Chetankumar
    B. E. Kumara Swamy
    T. S. Sunil Kumar Naik
    Journal of Materials Science: Materials in Electronics, 2020, 31 : 19728 - 19740
  • [5] Electrochemical detection of bisphenol A in presence of catechol and hydroquinone at copper oxide modified carbon paste electrode
    Shruthi Vishwanath, M.
    Kumara Swamy, B. E.
    Vishnumurthy, K. A.
    MATERIALS CHEMISTRY AND PHYSICS, 2022, 289
  • [6] A reliable electrochemical sensor for detection of catechol and hydroquinone at MgO/GO modified carbon paste electrode
    Chetankumar, K.
    Swamy, B. E. Kumara
    Naik, T. S. Sunil Kumar
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2020, 31 (22) : 19728 - 19740
  • [7] Electrochemical Behavior of Hydroquinone and Catechol at a Silsesquioxane-Modified Carbon Paste Electrode
    da Silva, Paulo S.
    Gasparini, Bianca C.
    Magosso, Herica A.
    Spinelli, Almir
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2013, 24 (04) : 695 - 699
  • [8] MIL-101 (Fe) modified carbon paste electrode for the efficient simultaneous detection of hydroquinone and catechol
    Zhu, Mengting
    Xu, Ruli
    Wang, Xueyang
    Liu, Jie
    Zhang, Qianli
    Wei, Jie
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (12):
  • [9] NiO nanoparticles modified carbon paste electrode for the voltammetric simultaneous detection of catechol and hydroquinone as environmental pollutants
    Achache, Mohamed
    Ben Seddik, Nordin
    Bouchta, Dounia
    Draoui, Khalid
    Choukairi, Mohamed
    MICROCHEMICAL JOURNAL, 2025, 208
  • [10] Simultaneous determination of hydroquinone and catechol using a modified glassy carbon electrode by ruthenium red/carbon nanotube
    Mohammad Mehdi Foroughi
    Meissam Noroozifar
    Mozhgan Khorasani-Motlagh
    Journal of the Iranian Chemical Society, 2015, 12 : 1139 - 1147