The Effect of Dimple Insole Design on the Plantar Temperature and Pressure in People with Diabetes and in Healthy Individuals

被引:1
|
作者
Zequera, Martha [1 ]
Almenar-Arasanz, Alejandro J. [2 ,3 ]
Alfaro-Santafe, Javier [2 ]
Allan, David [4 ]
Anaya, Andres [1 ]
Cubides, Mauricio [1 ]
Rodriguez, Natalia [1 ]
Salazar, Cesar [1 ]
Naemi, Roozbeh [5 ,6 ]
机构
[1] Pontificia Univ Javeriana, Sch Engn, Elect Dept, Baspi Footlab, Ave Carrera 7 41-20, Bogota 11023, Bogota, Colombia
[2] Podoactiva, Dept Res & Innovat, Technol Pk Walqa,Ctra N 330 Km 566, Huesca 22197, Spain
[3] St Jorge Univ, Campus Univ, Physiotherapy Dept, Autovia Mudejar Km 299, Zaragoza 50830, Spain
[4] Univ Ulster, Fac Life Sci, Sch Sport, 2-24 York St, Belfast BT15 1AP, North Ireland
[5] Staffordshire Univ, Ctr Biomech & Rehabil Technol, Sch Hlth Sci & Wellbeing, Leek Rd, Stoke On Trent ST4 2DF, England
[6] Univ Salford, Ctr Human Movement & Rehabil, Sch Hlth & Soc, Fredrick Rd, Manchester M6 6PU, England
关键词
diabetic foot; thermography; orthotics; plantar pressure; foot ulcer; thermal imaging; foot temperature; dimple insole; walking; FOOT; PREVENTION;
D O I
10.3390/s24175579
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An increase in plantar pressure and skin temperature is commonly associated with an increased risk of diabetic foot ulcers. However, the effect of insoles in reducing plantar temperature has not been commonly studied. The aim was to assess the effect of walking in insoles with different features on plantar temperature. Twenty-six (F/M:18/8) participants-13 with diabetes and 13 healthy, aged 55.67 +/- 9.58 years-participated in this study. Skin temperature at seven plantar regions was measured using a thermal camera and reported as the difference between the temperature after walking with an insole for 20 m versus the baseline temperature. The mixed analyses of variance indicated substantial main effects for the Insole Condition, for both the right [Wilks' Lambda = 0.790, F(14, 492) = 4.393, p < 0.01, partial eta squared = 0.111] and left feet [Wilks' Lambda = 0.890, F(14, 492) = 2.103, p < 0.011, partial eta squared = 0.056]. The 2.5 mm-tall dimple insole was shown to be significantly more effective at reducing the temperature in the hallux and third met head regions compared to the 4 mm-tall dimple insole. The insoles showed to be significantly more effective in the diabetes group versus the healthy group, with large effect size for the right [Wilks' Lambda = 0.662, F(14, 492) = 8.037, p < 0.000, Partial eta-squared = 0.186] and left feet [Wilks' Lambda = 0.739, F(14, 492) = 5.727, p < 0.000, Partial eta-squared = 0.140]. This can have important practical implications for designing insoles with a view to decrease foot complications in people with diabetes.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] A Wearable Insole System to Measure Plantar Pressure and Shear for People with Diabetes
    Tang, Jinghua
    Bader, Dan L.
    Moser, David
    Parker, Daniel J.
    Forghany, Saeed
    Nester, Christopher J.
    Jiang, Liudi
    SENSORS, 2023, 23 (06)
  • [2] Design and Implementation of a Smart Insole System to Measure Plantar Pressure and Temperature
    Khandakar, Amith
    Mahmud, Sakib
    Chowdhury, Muhammad E. H.
    Reaz, Mamun Bin Ibne
    Kiranyaz, Serkan
    Bin Mahbub, Zaid
    Ali, Sawal Hamid Md
    Bakar, Ahmad Ashrif A.
    Ayari, Mohamed Arselene
    Alhatou, Mohammed
    Abdul-Moniem, Mohammed
    Faisal, Md Ahasan Atick
    SENSORS, 2022, 22 (19)
  • [3] Plantar pressure analysis of accommodative insole in older people with metatarsalgia
    Chang, Bao-Chi
    Liu, Ding-Hao
    Chang, Jeffrey Liao
    Lee, Si-Huei
    Wang, Jia-Yi
    GAIT & POSTURE, 2014, 39 (01) : 449 - 454
  • [4] THE EFFECT OF CARBON INSOLE USE ON FOOT PLANTAR PRESSURE DISTRIBUTION IN INDIVIDUALS WITH PES PLANUS AND PES CAVUS
    Turan, Can
    Aras Bayram, Gulay
    TURKISH JOURNAL OF PHYSIOTHERAPY REHABILITATION-TURK FIZYOTERAPI VE REHABILITASYON DERGISI, 2022, 33 (02): : 81 - 88
  • [5] Design Consideration of Data Acquisition System for Capacitive Plantar Pressure Insole
    Nugroho, Asep
    Gustiandi, Reyhan
    Damayanti, Kristiana Asih
    Rozaqi, Latif
    Sanjaya, Kadek Heri
    Bahrudin
    2022 INTERNATIONAL CONFERENCE ON RADAR, ANTENNA, MICROWAVE, ELECTRONICS, AND TELECOMMUNICATIONS (ICRAMET): EMERGING SCIENCE AND INDUSTRIAL INNOVATION IN ELECTRONICS AND TELECOMMUNICATION, 2022, : 1 - 5
  • [6] A Polyester-Nylon Blend Plantar Pressure Sensing Insole for Person With Diabetes
    Tiwari, Bhawnath
    Ntella, Sofia Lydia
    Jeanmonod, Kenny
    Germano, Paolo
    Koechli, Christian
    Pataky, Zoltan
    Civet, Yoan
    Perriard, Yves
    IEEE SENSORS LETTERS, 2024, 8 (01) : 1 - 4
  • [7] Footwear and insole design features that reduce neuropathic plantar forefoot ulcer risk in people with diabetes: a systematic literature review
    Sayed Ahmed
    Alex Barwick
    Paul Butterworth
    Susan Nancarrow
    Journal of Foot and Ankle Research, 13
  • [8] Footwear and insole design features that reduce neuropathic plantar forefoot ulcer risk in people with diabetes: a systematic literature review
    Ahmed, Sayed
    Barwick, Alex
    Butterworth, Paul
    Nancarrow, Susan
    JOURNAL OF FOOT AND ANKLE RESEARCH, 2020, 13 (01)
  • [9] PLANTAR PRESSURE PATTERNS IN PEOPLE WITH GOUT AND DIABETES
    Rome, Keith
    Stewart, Sarah
    RHEUMATOLOGY, 2017, 56 : 98 - 98
  • [10] Fiber Bragg Gratings based smart insole to measure plantar pressure and temperature
    Mahmud, Sakib
    Khandakar, Amith
    Chowdhury, Muhammad E. H.
    AbdulMoniem, Mohammed
    Reaz, Mamun Bin Ibne
    Bin Mahbub, Zaid
    Sadasivuni, Kishor Kumar
    Murugappan, M.
    Alhatou, Mohammed
    SENSORS AND ACTUATORS A-PHYSICAL, 2023, 350