Percutaneous Extraction of Transvenous Permanent Pacemaker/Defibrillator Leads-A Single-Center Experience

被引:0
|
作者
Akcay, Murat [1 ]
Yuksel, Serkan [1 ]
机构
[1] Ondokuz Mayis Univ, Sch Med, Dept Cardiol, TR-55139 Samsun, Turkiye
来源
MEDICINA-LITHUANIA | 2024年 / 60卷 / 08期
关键词
transvenous lead extraction; indications; outcomes; single-center experience; EXPERT CONSENSUS STATEMENT; DEFIBRILLATOR LEADS; CONTROLLED ELECTRA; MORTALITY; PACEMAKER; PREDICTORS; OUTCOMES; REGISTRY; REMOVAL; SAFETY;
D O I
10.3390/medicina60081360
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Objectives: The number of cardiac pacemakers being used has increased in recent decades, and this increase has led to a rise in device-related complications, requiring percutaneous device extraction. Our aim was to present our single-center clinical experience in percutaneous lead extractions. Materials and Methods: We analyzed an observational retrospective cohort study of 93 patients for the transvenous removal of a total of 163 endocardial leads. We evaluated the device details, indications, lead characteristics, extraction methods, complications, reimplantation procedure, follow-up data, effectiveness, and safety. Results: Patients' mean age was 68.6 +/- 11.6 years. Lead extraction indications were pocket infection in 33 (35.5%), lead dysfunction in 33 (35.5%), and system upgrade in 21 (23%) cases, and lead endocarditis in 6 (6%) cases. The duration from implantation to extraction time was a detected median of 43 (24-87) months. The most common retracted lead type was the RV defibrillator lead (62%), and the lead fixation type was active for one hundred (61%) patients. A new device was inserted in 74 (80%) patients, and the device type was most commonly a CRT-D (61%). Patients were followed up at a median of 17 (8-36) months, and 18 patients (19%) died at follow-up. Complete procedural success was obtained in 78 (84%) patients, and clinical procedural success was obtained in 83 (89%) patients. Procedural failure was detected in 15 (16%) patients. Major and minor complications were detected in 10 (11%) and 6 (6.5%) patients, respectively. The most common minor complication was pocket hematoma. Conclusions: Our experience suggests that transvenous lead extraction has a high success rate with an acceptable risk of procedural complications. The simple manual traction method has a high rate of procedural success, despite a high dwell time of the lead.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Percutaneous Extraction of Transvenous Permanent Pacemaker/Defibrillator Leads
    Paraskevaidis, Stylianos
    Konstantinou, Dimitrios
    Vassilikos, Vassilios
    Theofilogiannakos, Efstratios
    Mantziari, Lilian
    Megarisiotou, Athanasia
    Galitsianos, Ioannis
    Karvounis, Charalambos
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [2] Endocardial pacemaker or defibrillator leads with infected vegetations: A single-center experience and consequences of transvenous extraction
    Meier-Ewert, HK
    Gray, ME
    John, RM
    AMERICAN HEART JOURNAL, 2003, 146 (02) : 339 - 344
  • [3] Feasibility and safety of percutaneous intravascular extraction of pacemaker and defibrillator leads in octogenarians: A single-center 10-year experience.
    Padder, T
    Kantharia, B
    Padder, F
    Samuels, F
    Saari, C
    Baessler, C
    Kutalek, S
    AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (5A): : 123G - 123G
  • [4] PERCUTANEOUS EXTRACTION OF CARDIAC PACEMAKER AND IMPLANTABLE CARDIOVERTER DEFIBRILLATOR LEADS WITH A NEW TOOL; A SINGLE CENTER EXPERIENCE
    Oto, Ali
    Aytemir, Kudret
    Kabakci, Giray
    Yorgun, Hikmet
    Canpolat, Ugur
    Kaya, Ergun Baris
    Ates, Ahmet Hakan
    Dural, Muhammet
    Sunman, Hamza
    Evranos, Banu
    Ulgen, Aysegul
    Ozkutlu, Hilmi
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 140 : S83 - S83
  • [5] Percutaneous extraction of pacemaker and defibrillator leads
    Centella, Tomasa
    Oliva, Enrique
    Garcia-Andrade, Ignacio
    Martin-Davila, Pilar
    Cobo, Javier
    Moya, Jose L.
    Hernandez-Madrid, Antonio
    Epeldegui, Antonio
    REVISTA ESPANOLA DE CARDIOLOGIA, 2007, 60 (06): : 607 - 615
  • [6] Pacemaker/defibrillator leads extraction: a single centre experience
    Golzio, P-G.
    Vinci, M.
    Pelissero, E.
    Fanelli, A.
    Ferraris, F.
    Gaita, F.
    EUROPEAN HEART JOURNAL, 2012, 33 : 13 - 13
  • [7] Transvenous extraction of pacemaker and implantable cardioverter defibrillator leads using Evolution® mechanical dilator sheath: a single center confirmatory experience
    Kocabas, Ugur
    Duygu, Hamza
    Eren, Nihan Kahya
    Akyildiz, Zehra Ilke
    Ozyildirim, Serhan
    Tuluce, Selcen Yakar
    Kiris, Tuncay
    Nazli, Cem
    SPRINGERPLUS, 2016, 5
  • [8] FEASIBILITY OF PERCUTANEOUS EXTRACTION OF TRANSVENOUS DEFIBRILLATOR LEADS
    MALONEY, JD
    WILKOFF, BL
    SMITH, HJ
    ZHU, WX
    CIRCULATION, 1995, 92 (08) : 719 - 719
  • [9] Transvenous Pacemaker and Defibrillator Lead Extraction in the Setting of Noninfectious Indications: A Large, Single Center Experience
    Mahoney, Timothy H.
    Alves, Carlos
    Wazni, Ousamma
    Martin, David O.
    Saliba, Walid
    Niebauer, Mark
    Varma, Niraj
    Callahan, Thomas
    Kanj, Mohamed
    Wilkoff, Bruce L.
    CIRCULATION, 2009, 120 (18) : S714 - S714
  • [10] SINGLE CENTRE EXPERIENCE WITH SEVERAL METHODS FOR EXTRACTION OF PERMANENT PACEMAKER AND IMPLANTABLE CARDIOVERTER DEFIBRILLATOR LEADS
    Oto, A.
    Aytemir, K.
    Yorgun, H.
    Canpolat, U.
    Ates, A. H.
    Sunman, H.
    Ulgen, A.
    Gurses, K. M.
    Kaya, E. B.
    Tokgozoglu, L.
    Kabakci, G.
    Ozkutlu, H.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 147 : S81 - S81