Performance analysis of a fresh air and indoor air co-treatment parallel-loop exhaust air heat pump for buildings

被引:0
|
作者
Li, Xiang [1 ]
Ma, Guoyuan [1 ]
Wang, Lei [1 ]
Xu, Shuxue [1 ]
Gao, Lei [1 ]
Wu, Junfeng [2 ]
机构
[1] Beijing Univ Technol, Beijing 100124, Peoples R China
[2] State Key Lab High End Compressor & Syst Technol, Hefei 230031, Anhui, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Building energy reduction; Parallel-loop; Ventilation energy recovery; Fresh air and indoor air co-treatment; Performance simulation; ENERGY; RECOVERY; TECHNOLOGIES; STRATEGIES;
D O I
10.1016/j.jobe.2024.110414
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To reduce building energy consumption and solve the problem that the power of traditional exhaust air heat pump is limited by exhaust air volume, an innovative fresh air and indoor air co- treatment parallel-loop exhaust air heat pump (CPEAHP) was proposed, and three operating modes of the CPEAHP were studied. The results showed that the co-treatment mode not only increased the flexibility of system regulation, but also improved the heating performance of the system at low temperature in winter. When the winter outdoor temperature was higher than 0 degrees C, the temperature efficiency of the co-treatment mode was higher than 100 %, and that efficiency was higher than 100 % under all outdoor temperature conditions in summer. At a winter outdoor temperature of-15 degrees C, the co-treatment mode could increase the temperature of fresh air by 20.4 degrees C and increase the temperature of indoor air by 3.1 degrees C, the heating capacity of the system was 6.3 kW and the COP was 8.7 at this time. At an outdoor temperature of 42 degrees C in summer, the co-treatment mode could decrease the temperature of fresh air by 22.8 degrees C and decrease the temperature of indoor air by 3.1 degrees C, the cooling capacity of the system was 7.3 kW and the COP was 4.5 at this time. These results demonstrated the excellent performance of CPEAHP system, and the application of CPEAHP system was expected to reduce building energy consumption and promote carbon neutrality in the construction industry.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Experimental study and operation optimization of a parallel-loop heat pump for exhaust air recovery in residential buildings
    Jia, Xiaoya
    Ma, Guoyuan
    Zhou, Feng
    Liu, Shuailing
    Wu, Guoqiang
    Sui, Qiuyu
    JOURNAL OF BUILDING ENGINEERING, 2022, 45
  • [2] The applicability and energy consumption of a parallel-loop exhaust air heat pump for environment control in ultra-low energy building
    Jia, Xiaoya
    Ma, Guoyuan
    Zhou, Feng
    Liu, Shuailing
    Wu, Guoqiang
    Sui, Qiuyu
    APPLIED THERMAL ENGINEERING, 2022, 210
  • [3] Fresh air rate in air conditioning buildings and indoor air quality
    Pei Qing-qing
    Liu Wei
    Zhou Zhi-ming
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2007, 14 : 95 - 98
  • [4] Exhaust Air Heat Pump Heat Recovery System for Apartment Buildings
    Koiv, T. -A.
    Mikola, A.
    Kuusk, K.
    2012 INTERNATIONAL CONFERENCE ON POWER AND ENERGY SYSTEMS (ICPES 2012), 2012, 13 : 250 - 255
  • [5] Exhaust air heat recovery in buildings
    Fehrm, M
    Reiners, W
    Ungemach, M
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2002, 25 (04): : 439 - 449
  • [6] Field monitoring data on a residential exhaust air heat pump system (air-to-air heat pump)
    Shirani, Arsalan
    Merzkirch, Alexander
    Roesler, Jennifer
    Leyer, Stephan
    Scholzen, Frank
    Maas, Stefan
    DATA IN BRIEF, 2021, 38
  • [7] Exhaust air heat pump operation and performance in five homes
    1600, Publ by ACEEE, Washington, DC, USA
  • [8] Performance analysis of a rooftop, air-to-air heat pump working with CO2
    Calabrese, Nicolandrea
    Mastrullo, Rita
    Mauro, Alfonso William
    Rovella, Paola
    Tammaro, Marcello
    APPLIED THERMAL ENGINEERING, 2015, 75 : 1046 - 1054
  • [9] Heat source shifting in buildings supplied by district heating and exhaust air heat pump
    Kensby, J.
    Truschel, A.
    Dalenback, J. O.
    15TH INTERNATIONAL SYMPOSIUM ON DISTRICT HEATING AND COOLING (DHC15-2016), 2017, 116 : 470 - 480
  • [10] Experimental study on heating performance of air source heat pump fresh air unit with fresh air and return air mixing in severe cold regions
    Ye, Jiayu
    Ni, Long
    ENERGY AND BUILDINGS, 2023, 283