StarDICE II: Calibration of an Uncooled Infrared Thermal Camera for Atmospheric Gray Extinction Characterization

被引:0
|
作者
Sommer, Kelian [1 ]
Plez, Bertrand [1 ]
Cohen-Tanugi, Johann [1 ,2 ]
Dagoret-Campagne, Sylvie [3 ]
Moniez, Marc [3 ]
Neveu, Jeremy [3 ,4 ,5 ]
Betoule, Marc [4 ,5 ]
Bongard, Sebastien [4 ,5 ]
Feinstein, Fabrice [6 ]
Le Guillou, Laurent [4 ,5 ]
Juramy, Claire [4 ,5 ]
Sepulveda, Eduardo [4 ,5 ]
Souverin, Thierry [4 ,5 ]
机构
[1] Univ Montpellier, Ctr Natl Rech Sci, Lab Univers & Particules Montpellier, F-34095 Montpellier, France
[2] Univ Clermont Auvergne, Ctr Natl Rech Sci, Lab Phys Clermont, F-63000 Clermont Ferrand, France
[3] Univ Paris Saclay, Ctr Natl Rech Sci, IJCLab, F-91405 Orsay, France
[4] Ctr Natl Rech Sci, LPNHE, 4 Pl Jussieu, F-75005 Paris, France
[5] Sorbonne Univ, 4 Pl Jussieu, F-75005 Paris, France
[6] Aix Marseille Univ, Ctr Natl Rech Sci, CPPM, 163 Ave Luminy, F-13009 Marseille, France
关键词
uncooled infrared thermal camera calibration; cirrus cloud; atmosphere monitoring; gray extinction; low radiances; PRECIPITABLE WATER-VAPOR; NONUNIFORMITY CORRECTION; TEMPERATURE; CLOUDS; IMAGER;
D O I
10.3390/s24144498
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The StarDICE experiment strives to establish an instrumental metrology chain with a targeted accuracy of 1 mmag in griz bandpasses to meet the calibration requirements of next-generation cosmological surveys. Atmospheric transmission is a significant source of systematic uncertainty. We propose a solution relying on an uncooled infrared thermal camera to evaluate gray extinction variations. However, achieving accurate measurements with thermal imaging systems necessitates prior calibration due to temperature-induced effects, compromising their spatial and temporal precision. Moreover, these systems cannot provide scene radiance in physical units by default. This study introduces a new calibration process utilizing a tailored forward modeling approach. The method incorporates sensor, housing, flat-field support, and ambient temperatures, along with raw digital response, as input data. Experimental measurements were conducted inside a climatic chamber, with a FLIR Tau2 camera imaging a thermoregulated blackbody source. The results demonstrate the calibration effectiveness, achieving precise radiance measurements with a temporal pixel dispersion of 0.09 W m-2 sr-1 and residual spatial noise of 0.03 W m-2 sr-1. We emphasize that the accuracy of scene radiance retrieval can be systematically affected by the camera's close thermal environment, especially when the ambient temperature exceeds that of the scene.
引用
收藏
页数:23
相关论文
共 50 条
  • [1] Calibration of uncooled thermal infrared cameras
    Budzier, H.
    Gerlach, G.
    JOURNAL OF SENSORS AND SENSOR SYSTEMS, 2015, 4 (01) : 187 - 197
  • [2] Radiometric cloud imaging with an uncooled microbolometer thermal infrared camera
    Shaw, JA
    Nugent, PW
    Pust, NJ
    Thurairajah, B
    Mizutani, K
    OPTICS EXPRESS, 2005, 13 (15): : 5807 - 5817
  • [3] Quantitative thermal nondestructive evaluation using an uncooled microbolometer infrared camera
    Zalameda, JN
    Winfree, WP
    THERMOSENSE XXIV, 2002, 4710 : 610 - 617
  • [4] Superimpose methods for uncooled infrared camera applied to the micro-scale thermal characterization of composite materials
    Morikawa, Junko
    THERMOSENSE: THERMAL INFRARED APPLICATIONS XXXVII, 2015, 9485
  • [5] Uncooled Thermal Camera Calibration and Optimization of the Photogrammetry Process for UAV Applications in Agriculture
    Ribeiro-Gomes, Krishna
    Hernandez-Lopez, David
    Ortega, Jose F.
    Ballesteros, Rocio
    Poblete, Tomas
    Moreno, Miguel A.
    SENSORS, 2017, 17 (10)
  • [6] Development of Calibration Target for Infrared Thermal Imaging Camera
    Kim, Su Un
    Choi, Man Yong
    Park, Jeong Hak
    Shin, Kwang Yong
    Lee, Eui Chul
    JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2014, 34 (03) : 248 - 253
  • [7] Improved calibration-based non-uniformity correction method for uncooled infrared camera
    Liu, Chengwei
    Sui, Xiubao
    INFRARED SENSORS, DEVICES, AND APPLICATIONS VII, 2017, 10404
  • [8] A Calibration Procedure for Field and UAV-Based Uncooled Thermal Infrared Instruments
    Aragon, Bruno
    Johansen, Kasper
    Parkes, Stephen
    Malbeteau, Yoann
    Al-Mashharawi, Samir
    Al-Amoudi, Talal
    Andrade, Cristhian F.
    Turner, Darren
    Lucieer, Arko
    McCabe, Matthew F.
    SENSORS, 2020, 20 (11) : 1 - 24
  • [9] In situ calibration of an uncooled thermal camera for the accurate quantification of flower and stem surface temperatures
    Byerlay, Ryan A. E.
    Coates, Charlotte
    Aliabadi, Amir A.
    Kevan, Peter G.
    THERMOCHIMICA ACTA, 2020, 693 (693)
  • [10] Calibration and Characterization of a COTS Thermal Camera for Space
    Jain, Abhilasha
    Sukumar, K.
    Sahoo, Dhananjay
    Gupta, Ritvik
    Sarvani, B. S. R.
    Boratkar, Adheesh
    2016 IEEE AEROSPACE CONFERENCE, 2016,