Nonlinear optimal and multi-loop flatness-based control of induction motor-driven desalination units

被引:1
|
作者
Rigatos, G. [1 ]
Siano, P. [2 ]
AL-Numay, M. [3 ]
Abbaszadeh, M. [4 ]
Sari, B. [5 ]
机构
[1] Ind Syst Inst, Unit Ind Automat, Rion 26504, Greece
[2] Univ Salerno, Dept Management & Innovat Syst, I-84084 Fisciano, Italy
[3] King Saud Univ, Dept Elect Engn, Riyadh 11421, Saudi Arabia
[4] Rensselaer Polytech Inst, Dept ECS Engn, Troy 19000, NY USA
[5] Univ Set I, Dept Elect Engn, Setif, Algeria
来源
关键词
Desalination process; Reverse osmosis; Asynchronous motors; Differential flatness properties; Nonlinear H-infinity control; Flatness-based control in successive loops; Global stability; REVERSE-OSMOSIS DESALINATION; ENERGY MANAGEMENT; SYSTEM; WATER; OPTIMIZATION;
D O I
10.1016/j.rico.2023.100360
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
In this article, the control problem for the induction-motor driven reverse osmosis in desalination units is solved with the use of (i) a nonlinear optimal control method (ii) a flatness-based control approach which is implemented in successive loops. To apply method (i) that is nonlinear optimal control, the dynamic model of the induction-motor driven reverse-osmosis desalination units undergoes approximate linearization at each sampling instant with the use of first-order Taylor series expansion and through the computation of the associated Jacobian matrices. The linearization point is defined by the present value of the system's state vector and by the last sampled value of the control inputs vector. To compute the feedback gains of the optimal controller an algebraic Riccati equation is repetitively solved at each time-step of the control algorithm. The global stability properties of the nonlinear optimal control method are proven through Lyapunov analysis. To implement control method (ii), that is flatness-based control in successive loops, the state-space model of the induction-motor driven reverse-osmosis desalination unit is separated into three subsystems, which are connected in cascading loops. Each one of these subsystems can be viewed independently as a differentially flat system and control about it can be performed with inversion of its dynamics as in the case of input-output linearized flat systems. The state variables of the preceding (ith) subsystem become virtual control inputs for the subsequent (i+1th) subsystem. In turn, exogenous control inputs are applied to the first and third subsystem. The whole control method is implemented in three successive loops and its global stability properties are also proven through Lyapunov stability analysis. The proposed method achieves stabilization of the induction-motor-driven reverse osmosis desalination unit without the need of diffeomorphisms and complicated state-space model transformations.
引用
收藏
页数:30
相关论文
共 14 条
  • [1] Nonlinear Optimal and Multi-Loop Flatness-Based Control of Induction Motor-Driven Desalination Unitsdr. Gerasimos G. Rigatos Unit of Industrial Automation
    Rigatos, Gerasimos
    Siano, Pierluigi
    AL Numay, Mohammed
    Abbaszadeh, Masoud
    Sari, Bilal
    SSRN, 2023,
  • [2] Nonlinear optimal control for a gas compressor driven by an induction motor
    Rigatos, G.
    Abbaszadeh, M.
    Sari, B.
    Siano, P.
    Cuccurullo, G.
    Zouari, F.
    RESULTS IN CONTROL AND OPTIMIZATION, 2023, 11
  • [3] Nonlinear Differential Flatness-Based Speed/Torque Control With State-Observers of Permanent Magnet Synchronous Motor Drives
    Thounthong, Phatiphat
    Sikkabut, Suwat
    Poonnoy, Nitchamon
    Mungporn, Pongsiri
    Yodwong, Burin
    Kumam, Poom
    Bizon, Nicu
    Nahid-Mobarakeh, Babak
    Pierfederici, Serge
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2018, 54 (03) : 2874 - 2884
  • [4] Event-driven enabled regression aided multi-loop control for SEC minimisation in SWRO desalination considering salinity variation
    Joseph, Arun
    Damodaran, Vasanthi
    ISA TRANSACTIONS, 2022, 119 : 221 - 241
  • [5] Estimation of Electromagnetic Parameters of an Induction Motor Multi-loop Equivalent Circuit Based on the Machine Inductance Frequency Characteristic
    Rolek, Jaroslaw
    Kaplon, Andrzej
    Utrata, Grzegorz
    2015 SELECTED PROBLEMS OF ELECTRICAL ENGINEERING AND ELECTRONICS (WZEE), 2015,
  • [6] Adaptive resonant based multi-loop control strategy for parallel distributed generation units in standalone microgrid application
    Saim, Abdelhakim
    Mellah, Rabah
    Houari, Azeddine
    Machmoum, Mohamed
    Djerioui, Ali
    ELECTRIC POWER SYSTEMS RESEARCH, 2017, 143 : 262 - 271
  • [7] Flatness-Based Control Design for Two-Mass System Using Induction Motor Drive Fed by Voltage Source Inverter with Ideal Control Performance of Stator Current
    Vo Thanh Ha
    Nguyen Phung Quang
    ENGINEER OF THE XXI CENTURY, 2020, 70 : 39 - 50
  • [8] Optimal LQR-based Multi-loop Linear Control Strategy for UPS Inverter Applications using Resonant Controller
    Hasanzadeh, A.
    Edrington, C. S.
    Maghsoudlou, B.
    Mokhtari, H.
    2011 50TH IEEE CONFERENCE ON DECISION AND CONTROL AND EUROPEAN CONTROL CONFERENCE (CDC-ECC), 2011, : 3080 - 3085
  • [9] Nonlinear Control of Induction Motor Based on the Combined Multi-scalar Machine Model and Backstepping Approach
    Nemmour, A. L.
    Mehazzem, F.
    Khezzar, A.
    Hacil, M.
    Louze, L.
    Abdessemed, R.
    IECON: 2009 35TH ANNUAL CONFERENCE OF IEEE INDUSTRIAL ELECTRONICS, VOLS 1-6, 2009, : 3990 - +
  • [10] Nonlinear optimal control for the five-phase induction motor-based traction system of electric vehicles
    Rigatos, Gerasimos G.
    Siano, Pierluigi
    Al-Numay, Mohammed S.
    Sari, Bilal
    Abbaszadeh, Masoud
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2024, 43 (01) : 167 - 191