Misclassification of Eyes With Progressive Keratoconus Using the KISA% Index

被引:1
|
作者
Hammoud, Bassel [1 ]
Dupps Jr, William J. [1 ,2 ,3 ]
Scarcelli, Giuliano [4 ]
Randleman, J. Bradley [1 ,2 ]
机构
[1] Cleveland Clin, Cole Eye Inst, 9500 Euclid Ave,i-32, Cleveland, OH 44195 USA
[2] Case Western Reserve Univ, Cleveland Clin, Lerner Coll Med, Cleveland, OH USA
[3] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH USA
[4] Univ Maryland, Fischell Dept Bioengn, College Pk, MD USA
关键词
COLLAGEN CROSS-LINKING; SUBCLINICAL KERATOCONUS; CORNEAL TOMOGRAPHY; ECTASIA; VIDEOKERATOGRAPHY; VALIDATION; CLASSIFICATION; THICKNESS; DIAGNOSIS; SYSTEM;
D O I
10.3928/1081597X-20240726-01
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine the misclassification rate of the keratoconus percentage (KISA%) index efficacy in eyes with progressive keratoconus. Methods: This was a retrospective case-control study of consecutive patients with confirmed progressive keratoconus and a contemporaneous normal control group with 1.00 diopters or greater regular astigmatism. Scheimpflug imaging (Pentacam HR) was obtained for all patients. KISA% index and inferior-superior (IS) values were obtained from the Pentacam topometric/keratoconus staging map. Receiver operating characteristic curves were generated to determine the area under the receiver operating characteristic curve (AUROC), sensitivity, and specificity values. Results: There were 160 eyes from 160 patients evaluated, including 80 eyes from 80 patients with progressive keratoconus and 80 eyes from 80 control patients. There were 20 eyes (25%) with progressive keratoconus misclassified by the KISA% index, with 16 eyes (20%) of the progressive keratoconus cohort classified as normal (ie, KISA% < 60). There were 4 eyes (5%) with progressive keratoconus that would classify as having "normal topography" using the published criteria for very asymmetric ectasia with normal topography of KISA% less than 60 and IS value less than 1.45. All controls had a KISA% index value of less than 15. The optimal cut-off value to distinguish cohorts was 15.31 (AUROC = 0.972, 93.75% sensitivity). KISA% index values of 60 and 100 achieved low sensitivity (80% and 73.75%, respectively). Conclusions: The KISA% index misclassified a significant proportion of eyes with progressive keratoconus as normal. Although highly specific for clinical keratoconus, the KISA% index lacks sensitivity, does not effectively discriminate between normal and abnormal topography, and thus should not be used in large data analysis or artificial intelligence-based modeling.
引用
收藏
页码:e614 / e624
页数:11
相关论文
共 50 条
  • [1] Correlation of the KISA% index and Scheimpflug tomography in 'normal', 'subclinical', 'keratoconus-suspect' and 'clinically manifest' keratoconus eyes
    Steinberg, Johannes
    Aubke-Schultz, Silke
    Frings, Andreas
    Huelle, Jan
    Druchkiv, Vasyl
    Richard, Gisbert
    Katz, Toam
    Linke, Stephan J.
    ACTA OPHTHALMOLOGICA, 2015, 93 (03) : e199 - e207
  • [2] Revisiting corneal topography for the diagnosis of keratoconus: use of Rabinowitz's KISA% index
    Sedghipour, Mohammad Reza
    Sadigh, Afshin Lotfi
    Motlagh, Behzad Fallahi
    CLINICAL OPHTHALMOLOGY, 2012, 6 : 181 - 184
  • [3] KISA% index: A quantitative videokeratography algorithm embodying minimal topographic criteria for diagnosing keratoconus
    Rabinowitz, YS
    Rasheed, K
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (10): : 1327 - 1335
  • [4] Keratoconus detection with the KISA% method - Another view
    Klyce, SD
    Smolek, MK
    Maeda, N
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (04): : 472 - 473
  • [5] Keratoconus detection with the KISA% method - Another view - Reply
    Rabinowitz, YS
    Rasheed, K
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (04): : 473 - 474
  • [6] The Location Consistency Index Helps to Distinguish Eyes With Subclinical Keratoconus From Normal Eyes
    Wang, Mengyi
    Shi, Ce
    Zhou, Yuheng
    Ye, Yufeng
    Fan, Xin
    Huang, Huimin
    Yu, Xiangle
    Lu, Fan
    Shen, Meixiao
    JOURNAL OF REFRACTIVE SURGERY, 2022, 38 (01) : 35 - +
  • [7] Screening of Keratoconus Using Autokeratometer and Keratometer Keratoconus Index
    Kojima, Takashi
    Isogai, Naoki
    Nishida, Tomoya
    Nakamura, Tomoaki
    Ichikawa, Kazuo
    DIAGNOSTICS, 2021, 11 (11)
  • [8] Comparison of the variability of Scheimpflug imaging measurements between normal eyes, progressive and no-progressive keratoconus eyes at 1 year of follow up
    Zuniga Iracheta, Raul Alberto
    Camargo Acuna, Jorge
    Camino Quezada, Maythe Estephania
    Maldonado, Carmen
    Chauca, Jose
    Ruiz-Montenegro Villa, Katia
    Izquierdo, Luis
    Henriquez, Maria A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [9] KISA% index: a quantitative videokeratography algorithm embodying minimal topographic criteria for diagnosing keratoconus (vol 25, pg 1327, 1999)
    Rabinowitz, YS
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (04): : 480 - 480
  • [10] Ocular, corneal, and internal aberrations in eyes with keratoconus, forme fruste keratoconus, and healthy eyes
    Mohammad Naderan
    Ali Jahanrad
    Mahgol Farjadnia
    International Ophthalmology, 2018, 38 : 1565 - 1573