Feasibility Study of Experimental Protocol for the Time-Dependent Mechanical Response of Synthetic Tibia
被引:0
|
作者:
Mantecon, Ramiro
论文数: 0引用数: 0
h-index: 0
机构:
San Diego State Univ, Mech Engn Dept, Expt Mech Lab, 5500 Campanile Dr, San Diego, CA 92182 USA
Univ Carlos III Madrid, Dept Mech Engn, Ave Univ 30, Madrid 28911, SpainSan Diego State Univ, Mech Engn Dept, Expt Mech Lab, 5500 Campanile Dr, San Diego, CA 92182 USA
Mantecon, Ramiro
[1
,2
]
Ruiz, Alvaro
论文数: 0引用数: 0
h-index: 0
机构:
San Diego State Univ, Mech Engn Dept, Expt Mech Lab, 5500 Campanile Dr, San Diego, CA 92182 USASan Diego State Univ, Mech Engn Dept, Expt Mech Lab, 5500 Campanile Dr, San Diego, CA 92182 USA
Ruiz, Alvaro
[1
]
Wheatley, Benjamin M.
论文数: 0引用数: 0
h-index: 0
机构:
Naval Med Ctr San Diego, Dept Orthoped Surg, 34800 Bob Wilson Dr, San Diego, CA 92134 USASan Diego State Univ, Mech Engn Dept, Expt Mech Lab, 5500 Campanile Dr, San Diego, CA 92182 USA
Wheatley, Benjamin M.
[3
]
Diaz-Alvarez, Jose
论文数: 0引用数: 0
h-index: 0
机构:
Univ Carlos III Madrid, Dept Mech Engn, Ave Univ 30, Madrid 28911, SpainSan Diego State Univ, Mech Engn Dept, Expt Mech Lab, 5500 Campanile Dr, San Diego, CA 92182 USA
Diaz-Alvarez, Jose
[2
]
Miguelez, Henar
论文数: 0引用数: 0
h-index: 0
机构:
Univ Carlos III Madrid, Dept Mech Engn, Ave Univ 30, Madrid 28911, SpainSan Diego State Univ, Mech Engn Dept, Expt Mech Lab, 5500 Campanile Dr, San Diego, CA 92182 USA
Miguelez, Henar
[2
]
论文数: 引用数:
h-index:
机构:
Youssef, George
[1
]
机构:
[1] San Diego State Univ, Mech Engn Dept, Expt Mech Lab, 5500 Campanile Dr, San Diego, CA 92182 USA
[2] Univ Carlos III Madrid, Dept Mech Engn, Ave Univ 30, Madrid 28911, Spain
[3] Naval Med Ctr San Diego, Dept Orthoped Surg, 34800 Bob Wilson Dr, San Diego, CA 92134 USA
In this research, an experimental biomechanics construct was developed to reveal the mechanics of distal tibial fracture by submitting synthetic tibiae to cyclic loading, resulting in a combined stress state due to axial compression and bending loads. The synthetic tibia was fixed at the knee but allowed to rotate in the coronal and sagittal planes at the ankle. The first three loading regimes lasted for 4000 cycles/each, and the final until ultimate failure. After 12k +/- 80 cycles, the observed failure patterns closely resembled distal tibial fractures. The collected data during cyclic loading were fitted into a phenomenological model to deduce the time-dependent response of the synthetic tibiae. Images were also collected and analyzed using digital image correlation to deduce the full-field state of strain. The latter revealed that longitudinal strain contours extended in the proximal-distal direction. The transverse strain contours exemplified a medial-to-lateral distribution, attributed to the combined contributions of the Poisson's effect and the flexural deformation from axial and bending components of the applied load, respectively. The experimental construct, full-field characterization, and data analysis approaches can be extended to elucidate the effect of different fixation devices on the overall mechanical behavior of the bone and validate computational models in future research.