Label-free and sensitive fluorescent detection of Escherichia coli O157: H7 in milk based on cascade strand displacement amplification and G-quadruplex-thioflavin T

被引:2
|
作者
Pang, Lidong [1 ]
Su, Qunchao [1 ]
Cheng, Jingqi [1 ]
Liu, Biqi [1 ]
Man, Chaoxin [1 ]
Guo, Ling [1 ,2 ]
Yang, Xinyan [1 ]
Zhao, Qianyu [1 ]
Jiang, Yujun [1 ,2 ]
机构
[1] Northeast Agr Univ, Coll Food Sci, Key Lab Dairy Sci, Minist Educ, Harbin 150030, Peoples R China
[2] Food Lab Zhongyuan, Luohe 462300, Henan, Peoples R China
基金
中国国家自然科学基金;
关键词
Escherichia coli O157; H7; Cascade strand displacement amplification; G-quadruplex; Aptamer-functionalized magnetic beads; Fluorescent detection;
D O I
10.1016/j.foodcont.2024.110499
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
The development of a simple, rapid, sensitive, and accurate method for detecting Escherichia coli O157:H7 in complex matrices is critical for ensuring food safety. In this study, a fluorescent biosensor employing aptamer (Apt) -functionalized magnetic beads and cascade strand displacement amplification (SDA) was devised for the detection of E. coli O157:H7 in milk samples. E. coli O157:H7 is captured by the aptamer, causing the complementary DNA (cDNA) to not bind to the aptamer and to be released into the supernatant. Following magnetic separation, the cDNA present in the supernatant initiates the opening of the hairpin (HP) structures. This enables primers to attach to the opened HP, triggering the initial SDA process, which generates a substantial quantity of double -stranded DNA (dsDNA) and recycles cDNA to open more HP structures. The dsDNA activates a second SDA, producing single -stranded DNA (ssDNA) for template binding and instigating a third SDA process. Triple SDA leads to the production of numerous G-quadruplex sequences and the formation of a G-quadruplex structure in the presence of K + . The inclusion of ThT into the G-quadruplex significantly enhances fluorescence. Under optimal conditions, this approach can detect E. coli O157:H7 at levels as low as 10 1 CFU/mL in pure cultures within 2.5 h, with a broad linear detection range of 10 1 -10 6 CFU/mL. This method exhibits remarkable specificity towards the target bacteria over non -target bacteria. Furthermore, the technique has been effectively utilized for the detection of E. coli O157:H7 in milk samples. Notably, the method involves only two main steps, identification and amplification, significantly reducing contamination risks and minimizing operational steps.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Label-free and enzyme-free sensitive fluorescent method for detection of viable Escherichia coli O157:H7
    Chen, Shujuan
    Li, Yongsheng
    Fu, Zhenzhen
    Zeng, Yue
    He, Li
    Zhou, Kang
    Ao, Xiaoling
    Liu, Shuliang
    Zou, Likou
    ANALYTICAL BIOCHEMISTRY, 2018, 556 : 145 - 151
  • [2] Sensitive detection of Escherichia coli O157:H7 based on cascade signal amplification in ELISA
    Shan, Shan
    Liu, Daofeng
    Guo, Qi
    Wu, Songsong
    Chen, Rui
    Luo, Kai
    Hu, Liming
    Xiong, Yonghua
    Lai, Weihua
    JOURNAL OF DAIRY SCIENCE, 2016, 99 (09) : 7025 - 7032
  • [3] Label-free amperometric biosensor for Escherichia coli O157:H7 detection
    Dhull, Nidhi
    Kaur, Gurpreet
    Jain, Prateek
    Mishra, Priyanka
    Singh, Divya
    Ganju, Lilly
    Gupta, Vinay
    Tomar, Monika
    APPLIED SURFACE SCIENCE, 2019, 495
  • [4] A sensitive lateral flow biosensor for Escherichia coli O157:H7 detection based on aptamer mediated strand displacement amplification
    Wu, Wei
    Zhao, Shiming
    Mao, Yiping
    Fang, Zhiyuan
    Lu, Xuewen
    Zeng, Lingwen
    ANALYTICA CHIMICA ACTA, 2015, 861 : 62 - 68
  • [5] Label-free and highly sensitive fluorescent detection of bleomycin based on CRISPR-Cas12a and G-quadruplex-thioflavin T
    Liao, Xiaofei
    Luo, Nian
    Li, Mengyan
    Fu, Hao
    Zou, Li
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 381
  • [6] A Label-Free Electrochemical Immunosensor Modified with AuNPs for Quantitative Detection of Escherichia coli O157:H7
    Huang, Yanyan
    Wu, Zunyi
    Zhao, Guangying
    Dou, Wenchao
    JOURNAL OF ELECTRONIC MATERIALS, 2019, 48 (12) : 7960 - 7969
  • [7] Label-free capacitive immunosensor based on quartz crystal Au electrode for rapid and sensitive detection of Escherichia coli O157:H7
    Li, Dujuan
    Feng, Yangyang
    Zhou, Ling
    Ye, Zunzhong
    Wang, Jianping
    Ying, Yibin
    Ruan, Chuanmin
    Wang, Ronghui
    Li, Yanbin
    ANALYTICA CHIMICA ACTA, 2011, 687 (01) : 89 - 96
  • [8] A Label-Free Electrochemical Immunosensor Modified with AuNPs for Quantitative Detection of Escherichia coli O157:H7
    Yanyan Huang
    Zunyi Wu
    Guangying Zhao
    Wenchao Dou
    Journal of Electronic Materials, 2019, 48 : 7960 - 7969
  • [9] Simple sensitive rapid detection of Escherichia coli O157:H7 in food samples by label-free immunofluorescence strip sensor
    Song, Chunmei
    Li, Jianwu
    Liu, Jinxin
    Liu, Qing
    TALANTA, 2016, 156 : 42 - 47
  • [10] Label-free, PCR-free DNA Hybridization Detection of Escherichia coli O157:H7 Based on Electrochemical Nanobiosensor
    Minaei, Mohammad Ebrahim
    Saadati, Mojtaba
    Najafi, Mostafa
    Honari, Hossein
    ELECTROANALYSIS, 2016, 28 (10) : 2582 - 2589