Fracture resistance of CAD/CAM milled versus direct hand-made interim laminate veneers

被引:2
|
作者
Abuhammoud, Salahaldeen [1 ]
Emtier, Banan [2 ]
Fu, Chin-Chuan [3 ]
Rojas-Rueda, Silvia [4 ,5 ]
Jurado, Carlos A. [6 ]
Afrashtehfar, Kelvin I. [7 ,8 ,9 ,10 ]
机构
[1] Univ Iowa, Dept Prosthodont, Coll Dent & Dent Clin, Iowa City, IA USA
[2] Univ Iowa, Coll Dent & Dent Clin, Iowa City, IA USA
[3] Univ Alabama Birmingham, Dept Restorat Sci, Sch Dent, Birmingham, AL USA
[4] Univ Alabama Birmingham, Sch Dent, Dept Clin & Community Sci, Div Biomat, Birmingham, AL USA
[5] Pontif Javerian Univ, Sch Dent, Bogota, Colombia
[6] Univ Tennesse, Dept Gen Dent, Div Operat Dent, Hlth Sci Ctr,Coll Dent, Memphis, TN USA
[7] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, BE, Switzerland
[8] Ajman Univ, Coll Dent, Clin Sci Dept, Ajman, Emirate of Ajma, U Arab Emirates
[9] Aachen Univ Hosp, Dept Operat Dent Periodontol & Prevent Dent, Rhein Westfal TH RWTH, Aachen, Germany
[10] Klin Rekonstrukt Zahnmed Gerodontol, zmk Bern Zahnmed Klin, Med Fak, Univ Bern, Freiburgstr 7, CH-3010 Bern, Switzerland
关键词
Dental veneers; Dental materials; Dental prosthesis design; Fracture resistance; CAD/CAM systems; Provisional restorations; Partial restorations; Cosmetic dentistry; Aesthetic dentistry; Laminate veneers; Temporary restorations; Indirect restorations; Direct restorations; Dental restorations; Dental prosthesis; Interim restorations; CROWNS;
D O I
10.1016/j.sdentj.2024.04.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: Comparative studies of interim veneer restorations crafted using subtractive computer-aided manufacturing (s-CAM) milling technology and traditional direct hand-made approaches are needed. Purpose: This comparative in vitro study evaluated the fracture resistance of two types of provisional veneer restorations for maxillary central incisors: milled (s-CAM) and traditional direct hand-made bis-acryl veneers. Materials and methods: Fifty maxillary right central incisor veneers (25 specimens per group) were fabricated and divided according to the fabrication method: (1) s-CAM milled (Structure CAD, VOCO Dental); and (2) hand-made (Protemp Plus, 3M). The restorations were cemented onto 3D-printed resin dies using temporary cement and subjected to 1000 cycles of thermal cycling between 5 degrees and 55 degrees C. These restorations subsequently were subjected to compressive loading until fracture occurred. Images of the fractured samples were captured using a scanning electron microscope (SEM). Statistical analysis was performed using the one-way ANOVA test and the Mann-Whitney U test. Results: Significant differences (p < 0.001) in the fracture resistance were observed between the two groups. s-CAM milled interim veneers displayed higher fracture resistance values (439.60 +/- 26 N) compared to the traditional method (149.15 +/- 10 N). Conclusion: The manufacturing method significantly influences the fracture resistance of interim veneer restorations. s-CAM interim laminate veneer restorations for maxillary central incisors exhibit a fracture resistance superior to that of the traditional method using bis-acryl.
引用
收藏
页码:920 / 925
页数:6
相关论文
共 35 条
  • [1] Fracture Resistance of CAD/CAM Versus Traditional Interim Fixed Dental Prostheses
    Pop, Daniel Alexandru
    Malaescu, R.
    Marsavina, Liviu
    Hosszu, Tiberiu
    Rotar, Raul
    Goguta, Luciana
    Duma, Virgil Florin
    Negrutiu, Meda Lavinia
    Sinescu, Cosmin
    Jivanescu, Anca
    MATERIALE PLASTICE, 2018, 55 (03) : 361 - 363
  • [2] Fracture resistance of CAD/CAM occlusal veneers: A systematic review of laboratory studies
    Albelasy, Eman H.
    Hamama, Hamdi H.
    Tsoi, James K. H.
    Mahmoud, Salah H.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2020, 110
  • [3] Influence of material type, thickness and storage on fracture resistance of CAD/CAM occlusal veneers
    Albelasy, Eman
    Hamama, Hamdi H.
    Tsoi, James K. H.
    Mahmoud, Salah H.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2021, 119
  • [4] Comparative Analysis of Fracture Resistance between CAD/CAM Materials for Interim Fixed Prosthesis
    Abad-Coronel, Cristian
    Carrera, Elena
    Mena Cordova, Nancy
    Fajardo, Jorge I.
    Aliaga, Paulina
    MATERIALS, 2021, 14 (24)
  • [5] Comparative Fracture Resistance Analysis of Translucent Monolithic Zirconia Dioxide Milled in a CAD/CAM System
    Abad-Coronel, Cristian
    Paladines, Angeles
    Ulloa, Ana Liz
    Paltan, Cesar A.
    Fajardo, Jorge I.
    CERAMICS-SWITZERLAND, 2023, 6 (02): : 1179 - 1190
  • [6] Fracture Resistance of Chairside CAD/CAM Lithium Disilicate Partial and Full Coverage Crowns and Veneers for Maxillary Canines
    Rojas-Rueda, S.
    Hernandez, A., I
    Abuhammoud, S.
    Jurado, C. A.
    Fu, C-C
    Lawson, N. C.
    OPERATIVE DENTISTRY, 2025, 50 (01) : 59 - 66
  • [7] Fracture resistance of weakened roots restored with relined or milled CAD-CAM glass fiber posts
    Maia, Belizane das Gracas Oliveira
    Santos, Thais da Silva Alves
    Talge Carvalho, Claudio Antonio
    Verner, Francielle Silvestre
    Junqueira, Rafael Binato
    DENTAL MATERIALS JOURNAL, 2023, 42 (01) : 92 - 98
  • [8] Effect of Die Spacer Thickness on the Fracture Resistance of CAD/CAM Lithium Disilicate Veneers on Maxillary First Premolars
    Farag, Sherine Mohamed
    Ghoneim, Mona Mohamed
    Afifi, Rania Reda
    CLINICAL COSMETIC AND INVESTIGATIONAL DENTISTRY, 2021, 13 : 223 - 230
  • [9] Fracture strength and bonding interface morphology of CAD/CAM-fabricated ceramic laminate veneers on bleached enamel treated with two different antioxidants
    Zhang, Hong
    Chen, Jiawen
    Wang, Ying
    Yu, Yiyan
    Zhao, Yuanhang
    Song, Jiazhuo
    Zhang, Zhimin
    DENTAL MATERIALS JOURNAL, 2023, 42 (04) : 559 - 567
  • [10] Resistance of CAD/CAM composite resin and ceramic occlusal veneers to fatigue and fracture in worn posterior teeth: A systematic review
    Maldonado, Karelys Del Cisne
    Espinoza, Juan Andres
    Astudillo, Daniela Andrea
    Delgado, Bolivar Andres
    Bravo, Wilson Daniel
    DENTAL AND MEDICAL PROBLEMS, 2024, 61 (03) : 417 - 426