Predictors for a Collar Sign and its Association with Outcomes in Aneurysms after Pipeline Embolization

被引:0
|
作者
Salih, Mira [1 ]
Young, Michael [1 ]
Shutran, Max [1 ]
Filo, Jean [1 ]
Taussky, Philipp [1 ]
Ogilvy, Christopher S. [1 ]
机构
[1] Harvard Med Sch, Beth Israel Deaconess Med Ctr, Neurosurg Serv, Brain Aneurysm Inst, Boston, MA 02115 USA
关键词
Collar sign; Flow diversion; Pipeline embolization; Unruptured cerebral aneurysms; INCOMPLETELY OCCLUDED ANEURYSMS;
D O I
10.1016/j.wneu.2023.12.062
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
- BACKGROUND: The collar sign has been previously described as an angiographic indicator of incomplete occlusion after deployment of a pipeline embolization device (PED) for intracranial aneurysms. In the present study, we explore the predictors for a collar sign in aneurysms treated with the PED. - METHODS: Aneurysms with a collar sign at the initial follow-up angiogram were identified in a retrospective review of single -center data. The predictors of a collar sign were analyzed through univariate and multivariate analyses. RESULTS: A total of 492 cases of cerebral aneurysm treated with the PED were identified. Among them, 53 were found to have a collar sign on the initial follow-up angiogram. Univariate analysis showed that previous treatment of the same aneurysm (odds ratio [OR], 2.46; P = 0.01), a branch vessel from the aneurysm neck or dome (OR, 6.2; P < 0.001), and a smaller aneurysm neck size (OR, 0.75; P = 0.01) were all predictors for the presence of a collar sign. A larger diameter (OR, 0.92; P = 0.06), increased dome/neck ratio (OR, 1.38; P = 0.1), increased aspect ratio (OR, 1.14; 0 P = .17), and previous treatment showed a trend toward an association with a collar sign. However, after multivariate analysis, a branch from the aneurysm neck or dome (OR, 6.23; P < 0.001), aneurysm diameter (OR, 0.75; P = 0.032), an increased dome/neck ratio (OR, 4.62; P = 0.006), and previous treatment were the strongest predictors for a collar sign. CONCLUSIONS: The presence of a branch vessel arising from the aneurysm neck or dome, an increased dome/neck ratio, aneurysm diameter, and previous treatment are the strongest predictive factors for a collar sign in the angiographic follow-up of PED-treated aneurysms.
引用
收藏
页码:E237 / E242
页数:6
相关论文
共 50 条
  • [1] The Collar Sign in Pipeline Embolization Device-Treated Aneurysms
    Moran, Christopher J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2020, 41 (03) : 486 - 487
  • [2] Collar Sign in Incompletely Occluded Aneurysms after Pipeline Embolization: Evaluation with Angiography and Optical Coherence Tomography
    Griessenauer, C. J.
    Gupta, R.
    Shi, S.
    Alturki, A.
    Motiei-Langroudi, R.
    Adeeb, N.
    Ogilvy, C. S.
    Thomas, A. J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2017, 38 (02) : 323 - 326
  • [3] Implications of the Collar Sign in Incompletely Occluded Aneurysms after Pipeline Embolization Device Implantation: A Follow-Up Study
    Gomez-Paz, S.
    Akamatsu, Y.
    Moore, J. M.
    Ogilvy, C. S.
    Thomas, A. J.
    Griessenauer, C. J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2020, 41 (03) : 482 - 485
  • [4] Emergence of the white-collar sign after coil embolization of cerebral aneurysms
    Satoshi Kiyofuji
    Yuji Matsumaru
    Wataro Tsuruta
    Mikito Hayakawa
    Yuki Kamiya
    Acta Neurochirurgica, 2014, 156 : 11 - 16
  • [5] Emergence of the white-collar sign after coil embolization of cerebral aneurysms
    Kiyofuji, Satoshi
    Matsumaru, Yuji
    Tsuruta, Wataro
    Hayakawa, Mikito
    Kamiya, Yuki
    ACTA NEUROCHIRURGICA, 2014, 156 (01) : 11 - 16
  • [6] In-Stent Stenosis After Pipeline Embolization Device in Intracranial Aneurysms: Incidence, Predictors, and Clinical Outcomes
    Turhon, Mirzat
    Kang, Huibin
    Liu, Jian
    Zhang, Yisen
    Zhang, Ying
    Huang, Jiliang
    Wang, Kun
    Li, Mengxing
    Liu, Jianmin
    Zhang, Hongqi
    Li, Tianxiao
    Song, Donglei
    Zhao, Yuanli
    Luo, Bin
    Maimaiti, Aierpati
    Aisha, Maimaitili
    Wang, Yunyan
    Feng, Wenfeng
    Wang, Yang
    Wan, Jieqing
    Mao, Guohua
    Shi, Huaizhang
    Yang, Xinjian
    Guan, Sheng
    NEUROSURGERY, 2022, 91 (06) : 943 - 951
  • [7] Predictors of Clinical Outcome After Treatment of Intracranial Aneurysms with the Pipeline Embolization Device
    Griffin, Andrew
    Reese, Vanessa
    Huseyinoglu, Zeynep
    Niedzwiecki, Donna
    Yang, Lexie
    Cutler, Andrew
    Gonzalez, L. Fernando
    Zomorodi, Ali
    Smith, Tony
    Hauck, Erik F.
    WORLD NEUROSURGERY, 2019, 130 : E666 - E671
  • [8] Lack of Association between Statin Use and Angiographic and Clinical Outcomes after Pipeline Embolization for Intracranial Aneurysms
    Brinjikji, W.
    Cloft, H.
    Cekirge, S.
    Fiorella, D.
    Hanel, R. A.
    Jabbour, P.
    Lylyk, P.
    McDougall, C.
    Moran, C.
    Siddiqui, A.
    Szikora, I.
    Kallmes, D. F.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2017, 38 (04) : 753 - 758
  • [9] Letter: In-Stent Stenosis After Pipeline Embolization Device in Intracranial Aneurysms: Incidence, Predictors, and Clinical Outcomes
    Sirakov, Alexander
    Vladev, Georgi
    Sirakova, Kristina
    Sirakov, Stanimir
    NEUROSURGERY, 2023, 93 (04) : E113 - E114
  • [10] The white-collar sign after Neuroform Atlas stent-assisted coil embolization of unruptured intracranial aneurysms
    Tachi, Rintaro
    Fuga, Michiyasu
    Tanaka, Toshihide
    Teshigawara, Akihiko
    Kajiwara, Ikki
    Irie, Koreaki
    Ishibashi, Toshihiro
    Hasegawa, Yuzuru
    Murayama, Yuichi
    NEURORADIOLOGY JOURNAL, 2024, 37 (05): : 593 - 602