Investigating the suitability of online flow cytometry for monitoring full-scale drinking water ozone system disinfection effectiveness

被引:2
|
作者
Dowdell, Katherine S. [1 ]
Olsen, Kirk [1 ]
Paz, Ernesto F. Martinez [1 ]
Sun, Aini [1 ]
Keown, Jeff [2 ]
Lahr, Rebecca [2 ]
Steglitz, Brian [2 ]
Busch, Andrea [3 ]
Lipuma, John J. [4 ]
Olson, Terese [1 ]
Raskin, Lutgarde [1 ]
机构
[1] Univ Michigan, Dept Civil & Environm Engn, 1353 Beal Ave, Ann Arbor, MI 48109 USA
[2] City Ann Arbor, Ann Arbor Water Treatment Plant, 919 Sunset Rd, Ann Arbor, MI 48103 USA
[3] Great Lakes Water Author, 9300 W Jefferson Ave, Detroit, MI 48209 USA
[4] Univ Michigan Med Sch, Dept Pediat, 8323 MSRB III,SPC5646,1150 W Med Cntr Dr, Ann Arbor, MI 48109 USA
基金
美国国家科学基金会;
关键词
Flow cytometry; Disinfection; Online microbial monitoring; Drinking water; Ozone; BACTERIAL-CELL COUNTS; ESCHERICHIA-COLI; WASTE-WATER; OZONATION; INACTIVATION; QUALITY; MICROBIOME; OPTIMIZATION; EFFICIENCY; FILTRATION;
D O I
10.1016/j.watres.2024.121702
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
While online monitoring of physicochemical parameters has widely been incorporated into drinking water treatment systems, online microbial monitoring has lagged behind, resulting in the use of surrogate parameters (disinfectant residual, applied dose, concentration x time, CT) to assess disinfection system performance. Online flow cytometry (online FCM) allows for automated quantification of total and intact microbial cells. This study sought to investigate the feasibility of online FCM for full-scale drinking water ozone disinfection system performance monitoring. A water treatment plant with high lime solids turbidity in the ozone contactor influent was selected to evaluate the online FCM in challenging conditions. Total and intact cell counts were monitored for 40 days and compared to surrogate parameters (ozone residual, ozone dose, and CT) and grab sample assay results for cellular adenosine triphosphate (cATP), heterotrophic plate counts (HPC), impedance flow cytometry, and 16S rRNA gene sequencing. Online FCM provided insight into the dynamics of the full-scale ozone system, including offering early warning of increased contactor effluent cell concentrations, which was not observed using surrogate measures. Positive correlations were observed between online FCM intact cell counts and cATP levels (Kendall 's tau =0.40), HPC (Kendall 's tau =0.20), and impedance flow cytometry results (Kendall 's tau =0.30). Though a strong correlation between log intact cell removal and CT was not observed, 16S rRNA gene sequencing results showed that passage through the ozone contactor significantly changed the microbial community ( p < 0.05). Potential causes of the low overall cell inactivation in the contactor and the significant changes in the microbial community after ozonation include regrowth in the later chambers of the contactor and varied ozone resistance of drinking water microorganisms. This study demonstrates the suitability of direct, online microbial analysis for monitoring full-scale disinfection systems.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] FULL-SCALE OZONE DISINFECTION OF WASTE-WATER
    RAKNESS, KL
    HEGG, BA
    JOURNAL WATER POLLUTION CONTROL FEDERATION, 1980, 52 (03): : 502 - 511
  • [2] Mapping Dynamics of Bacterial Communities in a Full-Scale Drinking Water Distribution System Using Flow Cytometry
    Schleich, Caroline
    Chan, Sandy
    Pullerits, Kristjan
    Besmer, Michael D.
    Paul, Catherine J.
    Radstrom, Peter
    Keucken, Alexander
    WATER, 2019, 11 (10)
  • [3] Online monitoring and control of drinking water corrosion potential at a full-scale plant
    Zraick, F.
    Cazin, C.
    Bedry, S.
    Andres, M.
    Rabaud, B.
    WATER PRACTICE AND TECHNOLOGY, 2019, 14 (04) : 772 - 782
  • [4] Full-scale modelling of an ozone reactor for drinking water treatment
    Audenaert, Wim T. M.
    Callewaert, Manly
    Nopens, Ingmar
    Cromphout, Jan
    Vanhoucke, Robert
    Dumoulin, Ann
    Dejans, Pascal
    Van Hulle, Stijn W. H.
    CHEMICAL ENGINEERING JOURNAL, 2010, 157 (2-3) : 551 - 557
  • [5] Application of a multiphase CFD modelling approach to improve ozone residual monitoring and tracer testing strategies for full-scale drinking water ozone disinfection processes
    Zhang, Jianping
    Huck, Peter M.
    Stubley, Gordon D.
    Anderson, William B.
    JOURNAL OF WATER SUPPLY RESEARCH AND TECHNOLOGY-AQUA, 2008, 57 (02): : 79 - 92
  • [6] Online flow cytometric monitoring of microbial water quality in a full-scale water treatment plant
    Buysschaert, Benjamin
    Vermijs, Lotte
    Naka, Agathi
    Boon, Nico
    De Gusseme, Bart
    NPJ CLEAN WATER, 2018, 1
  • [7] Online flow cytometric monitoring of microbial water quality in a full-scale water treatment plant
    Benjamin Buysschaert
    Lotte Vermijs
    Agathi Naka
    Nico Boon
    Bart De Gusseme
    npj Clean Water, 1
  • [8] Full-scale application of an electrochemical disinfection solution in a municipal drinking water treatment plant
    de Sousa Filho, Jose Waldir
    Lenza, Giovanna Almeida
    Tonhela, Marquele Amorim
    de Araujo, Karla Santos
    Fernandes, David Maikel
    Pointer Malpass, Geoffroy Roger
    WATER AND ENVIRONMENT JOURNAL, 2022, 36 (01) : 86 - 95
  • [9] Trihalomethane and haloacetic acid disinfection by-products in full-scale drinking water systems
    Adams, C
    Timmons, T
    Seitz, T
    Lane, J
    Levotch, S
    JOURNAL OF ENVIRONMENTAL ENGINEERING, 2005, 131 (04) : 526 - 534
  • [10] Biofilms in Full-Scale Drinking Water Ozone Contactors Contribute Viable Bacteria to Ozonated Water
    Kotlarz, Nadine
    Rockey, Nicole
    Olson, Terese M.
    Haig, Sarah-Jane
    Sanford, Larry
    LiPuma, John J.
    Raskin, Lutgarde
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2018, 52 (05) : 2618 - 2628