PMUT-Based System for Continuous Monitoring of Bolted Joints Preload

被引:1
|
作者
Sanvito, Stefano [1 ]
Passoni, Marco [2 ]
Giusti, Domenico [3 ]
Terenzi, Marco [3 ]
Prelini, Carlo [2 ]
La Mura, Monica [4 ]
Savoia, Alessandro Stuart [4 ]
机构
[1] Univ Bergamo, Dept Engn & Appl Sci, Via Galvani 2, I-24044 Dalmine, Italy
[2] STMicroelectronics, Via C Olivetti 2, I-20864 Agrate Brianza, Italy
[3] STMicroelectronics, Via Tolomeo 1, I-20007 Cornaredo, Italy
[4] Roma Tre Univ, Dept Ind Elect & Mech Engn, Via Vasca Navale 84, I-00146 Rome, Italy
基金
欧盟地平线“2020”;
关键词
piezoelectric micromachined ultrasonic transducer; PMUT; MEMS; ultrasound; non-destructive testing; structural health monitoring; bolted joint; bolt preload; finite elements method; TRANSDUCERS;
D O I
10.3390/s24134150
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, we present a bolt preload monitoring system, including the system architecture and algorithms. We show how Finite Element Method (FEM) simulations aided the design and how we processed signals to achieve experimental validation. The preload is measured using a Piezoelectric Micromachined Ultrasonic Transducer (PMUT) in pulse-echo mode, by detecting the Change in Time-of-Flight (CTOF) of the acoustic wave generated by the PMUT, between no-load and load conditions. We performed FEM simulations to analyze the wave propagation inside the bolt and understand the effect of different configurations and parameters, such as transducer bandwidth, transducer position (head/tip), presence or absence of threads, as well as the frequency of the acoustic waves. In order to couple the PMUT to the bolt, a novel assembly process involving the deposition of an elastomeric acoustic impedance matching layer was developed. We achieved, for the first time with PMUTs, an experimental measure of bolt preload from the CTOF, with a good signal-to-noise ratio. Due to its low cost and small size, this system has great potential for use in the field for continuous monitoring throughout the operative life of the bolt.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] A feasibility study of a PMUT-based wearable sensor for the automatic monitoring of carotid artery parameters
    Savoia, Alessandro Stuart
    Matera, Riccardo
    Quaglia, Fabio
    Ricci, Stefano
    INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021), 2021,
  • [2] FREQUENCY AGILE PMUT-BASED ULTRASONIC COMMUNICATION LINKS
    Herrera, Bernard
    Pop, Flavius
    Cassella, Cristian
    Rinaldi, Matteo
    2019 IEEE 32ND INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS), 2019, : 974 - 977
  • [3] Miniaturized PMUT-Based Receiver for Underwater Acoustic Networking
    Herrera, Bernard
    Pop, Flavius
    Cassella, Cristian
    Rinaldi, Matteo
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2020, 29 (05) : 832 - 838
  • [4] Development of PMUT-Based High Sensitivity Gas Flow Sensor
    Pernu, Tapio
    Sillanpaa, Teuvo
    Karuthedath, Cyril Baby
    Sebastian, Abhilash Thanniyil
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2024, 33 (01) : 88 - 94
  • [5] ALN PMUT-BASED ULTRASONIC POWER TRANSFER FOR IMPLANTABLE ELECTRONICS
    Herrera, Bernard
    Pop, Flavius
    Cassella, Cristian
    Rinaldi, Matteo
    2019 20TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS & EUROSENSORS XXXIII (TRANSDUCERS & EUROSENSORS XXXIII), 2019, : 861 - 864
  • [6] Novel pMUT-based Acoustic Duplexer for Underwater and Intrabody Communication
    Pop, Flavius V.
    Herrera, Bernard
    Cassella, Cristian
    Chen, Guofeng
    Demirors, Emrecan
    Guida, Raffaele
    Melodia, Tommaso
    Rinaldi, Matteo
    2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,
  • [7] A PMUT-BASED ULTRASONIC PROBE USED FOR CONTACT FORCE SENSING
    Xu, Tingzhong
    Zhao, Libo
    Li, Zixuan
    Yuan, Jiawei
    Zhao, Yihe
    Luo, Guoxi
    Li, Jie
    Li, Zhiakang
    Yang, Ping
    Jiang, Zhuangde
    2021 34TH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS 2021), 2021, : 419 - 422
  • [8] Effects of fretting damage on preload relaxation in bolted composite joints
    Shen Y.
    Xiao Y.
    Fuhe Cailiao Xuebao/Acta Materiae Compositae Sinica, 2019, 36 (02): : 400 - 409
  • [9] Acquisition RX Chain for PMUT-Based Highly Integrated Ultrasound Imaging Systems
    Novaresi, Lara
    Terenzi, Marco
    Malcovati, Piero
    Mazzanti, Andrea
    Bonizzoni, Edoardo
    PRIME 2022: 17TH INTERNATIONAL CONFERENCE ON PHD RESEARCH IN MICROELECTRONICS AND ELECTRONICS, 2022, : 261 - 264
  • [10] Preload Monitoring of Bolted L-Shaped Lap Joints Using Virtual Time Reversal Method
    Du, Fei
    Xu, Chao
    Wu, Guannan
    Zhang, Jie
    SENSORS, 2018, 18 (06)