Investigation of conjugate heat and mass transfer in a sleeve-type hollow fiber membrane for liquid desiccant dehumidification

被引:1
|
作者
Zhou, Junming [1 ]
Zhao, Jinming [1 ]
Wang, Shichen [1 ]
Hu, Yuxing [1 ]
Niu, Xiaofeng [1 ]
Zhang, Kai [1 ]
Wang, Faming [2 ]
机构
[1] Nanjing Tech Univ, Coll Urban Construct, Nanjing 211816, Peoples R China
[2] Katholieke Univ Leuven, Dept Biosyst BIOSYST, Div Anim & Human Hlth Engn, Kasteelpark Arenberg 30, BE-3001 Leuven, Belgium
基金
中国国家自然科学基金;
关键词
Liquid desiccant; Membrane dehumidification; Heat and mass transfer; Distribution characteristics; LAMINAR-FLOW; REGENERATION; PERFORMANCE; RECOVERY; FLUID;
D O I
10.1016/j.csite.2024.104517
中图分类号
O414.1 [热力学];
学科分类号
摘要
In adiabatic conditions, the dehumidification capacity of hollow fibre membranes decreases as solution temperature rises. To address this limitation, this study proposed a novel approach based on sleeve -type hollow fibre membranes. The study focused on three distinct fluid streams and the sleeve -type hollow fibre membrane tube. A three-dimensional model of the dehumidifier was created, and the dehumidifier's heat transfer, mass transfer, and fluid flow characteristics were thoroughly analyzed and experimentally validated. The results showed that the average values of the Sherwood number and Nusselt number on the air side are significantly influenced by the Reynolds number. On the solution side of the sleeve -type hollow membrane, the average Nusselt number and Sherwood number are approximately 4.0 and 4.6, respectively. According to the research, 76 % of the resistance is accounted for by the mass transfer resistance on the membrane side. The study's conclusions provide insightful information for improving the design of sleevetype hollow fibre membrane dehumidifiers.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Conjugate heat and mass transfer in a cross-flow hollow fiber membrane contactor for liquid desiccant air dehumidification
    Zhang, Li-Zhi
    Huang, Si-Min
    Pei, Li-Xia
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2012, 55 (25-26) : 8061 - 8072
  • [2] Conjugate heat and mass transfer in a skewed flow hollow fiber membrane bank used for liquid desiccant air dehumidification
    Ouyang, Yu-Wen
    Zhang, Li-Zhi
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 93 : 23 - 40
  • [3] Conjugate heat and mass transfer in a hollow fiber membrane module for liquid desiccant air dehumidification: A free surface model approach
    Zhang, Li-Zhi
    Huang, Si-Min
    Chi, Jun-Hui
    Pei, Li-Xia
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2012, 55 (13-14) : 3789 - 3799
  • [4] An Analytical Solution to Heat and Mass Transfer in Hollow Fiber Membrane Contactors for Liquid Desiccant Air Dehumidification
    Zhang, Li-Zhi
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2011, 133 (09):
  • [5] Conjugate heat and mass transfer in a counter-flow spiral hollow fiber membrane tube bank for liquid desiccant air dehumidification
    Chen, Jie-Chao
    Yang, Yu
    Yang, Minlin
    Zhuang, Han-Li
    Deng, Bo
    Low, Elaine
    Huang, Si-Min
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2022, 177
  • [6] Heat and mass transfer deteriorations in an elliptical hollow fiber membrane tube bank for liquid desiccant air dehumidification
    Huang, Si-Min
    Qin, Frank G. F.
    Yang, Minlin
    Yang, Xiaoxi
    Zhong, Wen-Feng
    APPLIED THERMAL ENGINEERING, 2013, 57 (1-2) : 90 - 98
  • [7] Turbulent Heat and Mass Transfer Across a Hollow Fiber Membrane Tube Bank in Liquid Desiccant Air Dehumidification
    Huang, Si-Min
    Zhang, Li-Zhi
    Tang, Kai
    Pei, Li-Xia
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2012, 134 (08):
  • [9] Heat and mass transfer enhancement in a cross-flow elliptical hollow fiber membrane contactor used for liquid desiccant air dehumidification
    Huang, Si-Min
    Yang, Minlin
    JOURNAL OF MEMBRANE SCIENCE, 2014, 449 : 184 - 192
  • [10] Study of the Heat and Mass Transfer in a Dehumidification of liquid desiccant
    Salarian, Hesamoddin
    MECHANICAL AND AEROSPACE ENGINEERING, PTS 1-7, 2012, 110-116 : 120 - 126