Comparison of quantitative and qualitative anti-dsDNA assays

被引:0
|
作者
Selvaratnam, Rajeevan [1 ,2 ,7 ]
Srivastava, Pooja [3 ]
Tacker, Danyel H. [4 ]
Thebo, Jennifer [5 ,8 ]
Wheeler, Sarah E. [3 ,6 ]
机构
[1] BayCare Hlth Syst, Lab Serv, Tampa, FL USA
[2] Univ Toronto, Dept Lab Med & Pathobiol, Toronto, ON, Canada
[3] Univ Pittsburgh, Med Ctr, Dept Pathol, Pittsburgh, PA 15260 USA
[4] West Virginia Univ, Sch Med, Dept Pathol Anat & Lab Med, Morgantown, WV USA
[5] Cent Penn Alliance Lab, York, PA USA
[6] Univ Pittsburgh, Sch Med, Dept Pathol, Pittsburgh, PA 15260 USA
[7] Univ Hlth Network, Dept Clin Biochem, Lab Med Program, Toronto, ON, Canada
[8] Just Sci Solut, Otsego, MI USA
关键词
dsDNA; anti-dsDNA; systemic lupus erythematosus; SLE; Crithidia; IFA; enzyme immunoassay; EIA; multiplex immunoassay; MIA; systemic autoimmune rheumatic disease; SARD; SYSTEMIC-LUPUS-ERYTHEMATOSUS; DISEASE-ACTIVITY STATE; AUTOANTIBODIES; VALIDATION; ANTIBODIES; REMISSION;
D O I
10.1093/labmed/lmae035
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objective: In evaluation of systemic lupus erythematosus (SLE), anti-double-stranded DNA antibodies (anti-dsDNA) play a significant role in diagnosis, monitoring SLE activity, and assessing prognosis. However, evaluations of the performance and limitations for recently developed methods for anti-dsDNA assessment are sparse. Methods: Specimens used for antinuclear antibody testing (n = 129) were evaluated for anti-dsDNA assay comparability across 4 medical centers in the United States. The methods compared were Werfen Quanta Lite dsDNA, Zeus Scientific dsDNA Enzyme Immunoassay, Bio-Rad multiplex immunoassay (MIA) dsDNA, ImmunoConcepts Crithidia, and Bio-Rad Laboratories Crithidia. Results : For quantitative anti-dsDNA measurements, Spearman's correlation coefficient was highest between Zeus and Werfen (rho = 0.86; CI, 0.81-0.90; P < .0001). Comparison of MIA to Werfen or Zeus yielded similar results to each other (rho = 0.58; CI, 0.44-0.68; P < .0001; and rho = 0.59; CI, 0.46-0.69; P < .0001, respectively), but lower than the correlation between Zeus and Werfen. Positive concordance between assays ranged from 31.4% to 97.1%, and negative concordance between assays ranged from 58.5% to 100%. The detection of anti-dsDNA in those with SLE diagnosis ranged from 50.9% to 77.4% for quantitative assays and 15.1% to 24.5% for Crithidia assays. Conclusion: Current quantitative anti-dsDNA assays are not interchangeable for patient follow-up. Crithidia-based assays demonstrate high negative concordance and lack positive concordance among the methods.
引用
收藏
页码:732 / 738
页数:7
相关论文
共 50 条
  • [1] COMPARISON OF THE FIAX, FARR, AND CRITHIDIA ASSAYS FOR ANTI-DSDNA IN SLE
    BERNE, BH
    DEBLOCK, K
    WELTON, RC
    CLINICAL CHEMISTRY, 1983, 29 (06) : 1244 - 1244
  • [2] Clinical Comparison of QUANTA Flash dsDNA Chemiluminescent Immunoassay with Four Current Assays for the Detection of Anti-dsDNA Autoantibodies
    Infantino, Maria
    Meacci, Francesca
    Bentow, Chelsea
    Martis, Peter
    Benucci, Maurizio
    Afeltra, Antonella
    Rigon, Amelia
    Atzeni, Fabiola
    Sarzi-Puttini, Piercarlo
    Manfredi, Mariangela
    Mahler, Andmichael
    JOURNAL OF IMMUNOLOGY RESEARCH, 2015, 2015
  • [3] Clinical comparison of five assays for the detection of anti-dsdna antibodies and their correlation with complement consumption
    Ricchiuti, V.
    Obney, J. R.
    Holloway, B.
    Aure, M.
    Mahler, M.
    CLINICAL CHEMISTRY, 2024, 70
  • [4] Comparison of three anti-dsDNA assays: Performance and correlation with systemic lupus erythematosus disease activity
    Venner, Allison A.
    Ibanez, Dominique
    Gladman, Dafna D.
    Urowitz, Murray B.
    MacKinnon, Anne
    Blasutig, Ivan M.
    Yip, Paul M.
    CLINICAL BIOCHEMISTRY, 2013, 46 (4-5) : 317 - 320
  • [5] Anti-dsDNA antibodies in sarcoidosis
    Weinberg, I
    Vasiliev, L
    Gotsman, I
    SEMINARS IN ARTHRITIS AND RHEUMATISM, 2000, 29 (05) : 328 - 331
  • [6] SIGNIFICANCE OF ANTI-DSDNA PROFILES
    SWAAK, AJG
    AARDEN, LA
    LAKMAKER, F
    GROOT, ERD
    FELTKAMP, TEW
    ANNALS OF THE RHEUMATIC DISEASES, 1977, 36 (03) : 286 - 286
  • [7] MEASUREMENT OF ANTI-DSDNA - REPLY
    SWAAK, AJG
    STATIUSVANEPS, LW
    FELTKAMP, TEW
    AARDEN, LA
    ARTHRITIS AND RHEUMATISM, 1979, 22 (12): : 1414 - 1415
  • [8] Comparison of two different methods for quantitation of anti-dsDNA antibody
    Choi, J.
    Oh, G.
    CLINICAL CHEMISTRY, 2024, 70 : I159 - I159
  • [9] DETECTION OF ANTI-DSDNA AS A DIAGNOSTIC-TOOL - A PROSPECTIVE-STUDY IN 441 NON-SYSTEMIC LUPUS-ERYTHEMATOSUS PATIENTS WITH ANTI-DSDNA ANTIBODY (ANTI-DSDNA)
    SWAAK, T
    SMEENK, R
    ANNALS OF THE RHEUMATIC DISEASES, 1985, 44 (04) : 245 - 251
  • [10] The performance of different anti-dsDNA autoantibodies assays in Chinese systemic lupus erythematosus patients
    Jiangfeng Zhao
    Kaiwen Wang
    Xiaodong Wang
    Ting Li
    Li Guo
    Liyang Gu
    Zhiwei Chen
    Fangfang Sun
    Haiting Wang
    Jiajie Li
    Jiaxian Huang
    Peng Zhang
    Yang Tang
    Shuang Ye
    Clinical Rheumatology, 2018, 37 : 139 - 144