Somatosensory alterations after single-unit dental implant immediate loading: A 1-year follow-up study

被引:0
|
作者
Herreira-Ferreira, Matheus [1 ]
Bonfante, Estevam Augusto [2 ]
Conti, Pauloesar Rodrigues [2 ]
Araujo-Junior, Everardo Napolea Santana de [2 ]
Machado, Camila Moreira [2 ]
Alves, Patrick Henry Machado [2 ]
Costa, Yuri Martins [3 ]
Bonjardim, Leonardo Rigoldi [1 ]
机构
[1] Univ Sao Paulo, Bauru Sch Dent, Dept Biol Sci, Bauru, Brazil
[2] Univ Sao Paulo, Bauru Sch Dent, Dept Prosthodont & Periodontol, Bauru, Brazil
[3] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Biosci, Piracicaba, Brazil
基金
巴西圣保罗研究基金会;
关键词
Dental implants; Single; -tooth; Immediate dental implant loading; Somatosensory Disorders; QUALITY-OF-LIFE; HEALED ALVEOLAR RIDGES; PLACEMENT; MULTICENTER; SURVIVAL; PAIN;
D O I
10.1016/j.jdent.2024.105148
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: This cohort study aimed to assess the incidence of somatosensory alterations after implant surgery using standardized quantitative and qualitative sensory testing. Methods: 33 participants with single-tooth loss, undergoing immediate implant loading were included. Quantitative Sensory Testing (QST) and Qualitative Sensory Testing (QualST) were conducted at eight time points over a year (baseline to 1 year). Two-Way Repeated Measures ANOVA and post hoc Tukey test were used on QST values and Cochran Q test on QualST. Results: The study revealed significant increase in thermal thresholds overtime. At the operated side, overall Cold Pain Threshold (extraoral: p = 0.030; intraoral: p < 0.001), and Cold Detection Threshold (intraoral: p < 0.001) increased overtime. In contralateral region, maxilla Cold Detection Threshold (extraoral: p = 0.024; intraoral: p = 0.031), Warm Detection Threshold (extraoral: p = 0.026; intraoral: p = 0.047) and overall Cold Pain Threshold (extraoral and intraoral: p < 0.001) also increased. QualST showed extraoral pinprick (p = 0.032) and intraoral pinprick (p = 0.000), cold (p = 0.000) and touch (p = 0.002) stimuli abnormalities overtime. Conclusions: Somatosensory alterations after implant surgery were detected in both quantitative and qualitative sensory assessments, but rapidly decreased during the first follow-ups, and then continuously until 1-year.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] A Simplified Prosthetic Implant Loading Protocol: 1-Year Clinical Follow-Up Study
    Andreatta, Lorenzo
    Brailsford, Malin Bjursten
    Zwaan, Jakob
    INTERNATIONAL JOURNAL OF DENTISTRY, 2020, 2020
  • [2] Immediate single implant placement and loading in the aesthetic zone with a novel dental implant: a 1-year prospective single cohort study
    Carosi, P.
    Cardelli, P.
    Laureti, A.
    Leggeri, A.
    Lorenzi, C.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2022, 36 (02): : 1 - 10
  • [3] Immediate functional loading of implants placed with flapless surgery in the edentulous maxilla: 1-year follow-up of a single cohort study
    Cannizzaro, Gioacchino
    Leone, Michele
    Esposito, Marco
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2007, 22 (01) : 87 - 95
  • [4] Clinical, Radiological, and Aesthetic Outcomes after Placement of a Bioactive-Surfaced Implant with Immediate or Delayed Loading in the Anterior Maxilla: 1-Year Retrospective Follow-Up Study
    Iacono, Roberta
    Mayer, Yaniv
    Marenzi, Gaetano
    Ferreira, Balan Vitor
    Pires, Godoy Eduardo
    Migliorati, Marco
    Bagnasco, Francesco
    PROSTHESIS, 2023, 5 (03): : 610 - 621
  • [5] The bone conduction implant - a review and 1-year follow-up
    Hakansson, Bo
    Reinfeldt, Sabine
    Persson, Ann-Charlotte
    Jansson, Karl-Johan Freden
    Rigato, Cristina
    Hultcrantz, Malou
    Eeg-Olofsson, Mans
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2019, 58 (12) : 945 - 955
  • [6] Innovative Alveolar Ridge Preservation Surgical Technique with Immediate Dental Implant Placement: A Retrospective Case Report of 1-Year Follow-Up
    Grassi, Andrea
    Monica, Daniele
    Minetti, Elio
    Ballini, Andrea
    Gianfreda, Francesco
    Bollero, Patrizio
    Cicciu, Marco
    Mastrangelo, Filiberto
    EUROPEAN JOURNAL OF DENTISTRY, 2024, 18 (01) : 408 - 414
  • [7] Custom-Made Root Analog Immediate Dental Implants: A Prospective Clinical Study with 1-Year Follow-up
    Akkoyun, Emine Fulya
    Demirba, Ahmet Emin
    Gumu, Hasan Onder
    Alkan, Banu Arzu
    Alkan, Alper
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (06) : 1223 - 1231
  • [8] Recovery of aphasia after stroke: a 1-year follow-up study
    Hanane El Hachioui
    Hester F. Lingsma
    Mieke E. van de Sandt-Koenderman
    Diederik W. J. Dippel
    Peter J. Koudstaal
    Evy G. Visch-Brink
    Journal of Neurology, 2013, 260 : 166 - 171
  • [9] Recovery of aphasia after stroke: a 1-year follow-up study
    El Hachioui, Hanane
    Lingsma, Hester F.
    van de Sandt-Koenderman, Mieke E.
    Dippel, Diederik W. J.
    Koudstaal, Peter J.
    Visch-Brink, Evy G.
    JOURNAL OF NEUROLOGY, 2013, 260 (01) : 166 - 171
  • [10] Falls in nonagenarians after 1-year of follow-up: The NonaSantfeliu study
    Formiga, Francesc
    Ferrer, Assumpta
    Duaso, Enric
    Lmedo, Claudia
    Pujol, Ramon
    ARCHIVES OF GERONTOLOGY AND GERIATRICS, 2008, 46 (01) : 15 - 23