A high-sensitivity compact dual-T-type resonant fiber-optic photoacoustic sensor for simultaneous detection of multiple gases

被引:4
|
作者
Zhang, Ming [1 ]
Wu, Guojie [2 ]
Gong, Zhenfeng [2 ]
Xing, Jiawei [3 ]
Wang, Xiaona [4 ]
Peng, Wei [4 ]
Yu, Qingxu [2 ]
Mei, Liang [2 ]
机构
[1] Dalian Univ Technol, Sch Elect Engn, Dalian 116024, Liaoning, Peoples R China
[2] Dalian Univ Technol, Sch Optoelect Engn & Instrumentat Sci, Dalian 116024, Liaoning, Peoples R China
[3] Dalian Univ Technol, Sch Dalian Univ Technol & Belarusian State Univ Jo, Dalian 116024, Liaoning, Peoples R China
[4] Dalian Univ Technol, Sch Phys, Dalian 116024, Liaoning, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Multiple gas detection; Photoacoustic spectroscopy; Fiber-optic acoustic sensor; Multi-resonant cavity; METHANE; SPECTROSCOPY; POWER; WAVE; SPECTROMETER; CANTILEVER; CELL; OIL;
D O I
10.1016/j.snb.2024.136328
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We propose a high-sensitivity compact dual-T-type resonant fiber-optic photoacoustic(DTR-FOPA) sensor for simultaneous detection of two gases. The designed DTR-FOPA sensor contains two T-type photoacoustic cells (PACs) and a cantilever-based fiber-optic acoustic sensor (CFOAS). The two T-type PACs are connected and the CFOAS is located in the middle of the two resonant cavities so that the photoacoustic signals from two resonant cavities can be measured simultaneously. Two collimators are mounted at each end of the two T-type PACs buffer chambers for transmitting the excitation light source. The performance of T-type PAC and CFOAS has been analyzed by theory and FEA software to obtain a highly sensitive dual gas sensor. The design high-performance CFOAS has a first-order intrinsic frequency of 2415 Hz and a sensitivity up to 17288 nm/Pa. Two distributed feedback lasers (DFBs) with wavelengths of 1532.8 nm and 1650.96 nm, a spectral demodulator, and a DTRFOPA sensor are used to realize a high-sensitivity simultaneous detection of methane (CH4) and acetylene (C2H2) gases. The minimum detection limits (MDLs) for CH4 and C2H2 are 65.7 ppb and 4.3 ppb, respectively with the integration time of 100 s, and the corresponding NNEA are 6.648 x 10-9 W center dot cm- 1 center dot Hz- 1/2 (CH4), 9.71 x 10-9 W center dot cm- 1 center dot Hz- 1/2 (C2H2). The miniaturized DTR-FOPA sensor features sensitivity and all-fiber optic connectivity, providing direction for long-range trace multi-gas simultaneous sensing.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] High-sensitivity fiber-optic acoustic sensor for photoacoustic spectroscopy based traces gas detection
    Gong, Zhenfeng
    Chen, Ke
    Yang, Yang
    Zhou, Xinlei
    Peng, Wei
    Yu, Qingxu
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 247 : 290 - 295
  • [2] All Fiber-Optic Photoacoustic Spectroscopy Sensor Combining Resonance and Nonresonance Photoacoustic Cells for High-Sensitivity Simultaneous Dual-Gas Sensing
    Wu, Guojie
    Ye, Hongxin
    Zhang, Xinyu
    Gong, Zhenfeng
    Tao, Pengcheng
    Peng, Wei
    Yu, Qingxu
    Mei, Liang
    IEEE SENSORS JOURNAL, 2024, 24 (19) : 30168 - 30175
  • [3] High-Sensitivity Fiber-Optic Sensor for Hydrogen Detection in Gas and Transformer Oil
    Fisser, Maximilian
    Badcock, Rodney A.
    Teal, Paul D.
    Hunze, Arvid
    IEEE SENSORS JOURNAL, 2019, 19 (09) : 3348 - 3357
  • [4] POROUS FIBER-OPTIC SENSOR FOR HIGH-SENSITIVITY HUMIDITY MEASUREMENTS
    ZHOU, Q
    SHAHRIARI, MR
    KRITZ, D
    SIGEL, GH
    ANALYTICAL CHEMISTRY, 1988, 60 (20) : 2317 - 2320
  • [5] Multiplexed fiber-optic photoacoustic sensors for simultaneous detection of multi-point gases
    Li, Chenxi
    Han, Xiao
    Ma, Fengxiang
    Zhao, Xinyu
    Wang, Zhengzhi
    Qi, Hongchao
    Guo, Min
    Chen, Ke
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 399
  • [6] Photoacoustic spectroscopy based multi-gas detection using high-sensitivity fiber-optic low-frequency acoustic sensor
    Gong, Zhenfeng
    Chen, Ke
    Yang, Yang
    Zhou, Xinlei
    Yu, Qingxu
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 260 : 357 - 363
  • [7] A New 3-D-Printed Nondestructive H-Like Resonant Fiber-Optic Photoacoustic Sensor for High-Sensitivity Remote Gas Sensing
    Wu, Guojie
    Ye, Hongxin
    Gong, Zhenfeng
    Mei, Liang
    IEEE SENSORS JOURNAL, 2024, 24 (22) : 36946 - 36952
  • [8] A simple, low-cost, high-sensitivity fiber-optic tilt sensor
    Bajic, Jovan S.
    Stupar, Dragan Z.
    Manojlovic, Lazo M.
    Slankamenac, Milos P.
    Zivanov, Milos B.
    SENSORS AND ACTUATORS A-PHYSICAL, 2012, 185 : 33 - 38
  • [9] Miniaturized High-Sensitivity Temperature Sensor Based on Cascaded Fiber-Optic FPI
    Liu, Yinggang
    Wen, Junliang
    Feng, Yanpei
    Huang, Liang
    Dong, Jingfei
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2023, 35 (08) : 430 - 433
  • [10] High-sensitivity intrinsic fiber-optic Fabry-Perot pressure sensor
    Kao, TW
    Taylor, HF
    OPTICS LETTERS, 1996, 21 (08) : 615 - 617