Evaluation of energy performance and ecological benefit of free-cooling system for data centers in worldwide climates

被引:5
|
作者
Fan, Chengliang [1 ,2 ]
Zou, Binwei [1 ]
Liao, Yundan [1 ]
Zhou, Xiaoqing [1 ,2 ]
机构
[1] Guangzhou Univ, Sch Architecture & Urban Planning, Sch Civil Engn, Guangzhou 510006, Peoples R China
[2] State Key Lab Subtrop Bldg & Urban Sci, Guangzhou 510640, Peoples R China
基金
中国国家自然科学基金;
关键词
Free cooling; System modeling; Performance evaluation; Data center; Optimal control; CHILLER PLANTS; SIMULATION; DESIGN; AIR;
D O I
10.1016/j.scs.2024.105509
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Water-side economizer (WSE) is an effective free-cooling solution aiming to enhance the natural cooling duration and in turn reduce the cooling-energy consumption of data centers. However, the system's performance is constrained by the limited understanding of its control mechanisms and the influence of local climatic conditions on its free-cooling capabilities. To overcome these limitations, a thermodynamic model of the WSE system with control strategies is provided and its adaptability performance in diverse worldwide locations is systematically evaluated. Modelica-based models of chiller plants and control strategies are firstly developed, and then the energy consumption and ecological benefit of the WSE system are investigated via large-scale simulations in worldwide climates. The performance indicators and application potential of the system are demonstrated through visualization maps. The analysis reveals significant energy savings potential of the WSE system, with the capacity to reduce annual cooling energy consumption of data centers by 4.4-33.7 % in hot to marine zones, and even by a remarkable 62.6 % in plateaus and cold zones. Furthermore, it is observed that every 1 degrees C increase in outdoor air temperature can reduce energy efficiency ratio by 1.3-8.7 % while simultaneously increase PUE by 0.3-1.0 %. The ecological benefit results revealed that the WSE system can effectively harness larger quantities of stable free-cooling resources in mixed and cool climate zones, exceeding its capabilities in hot and warm regions. These results offer valuable insights for the impact of climate on the energy and ecological benefits of WSE system for data center, which can be helpful to guide the design or retrofit of such cooling systems in specific locations, presenting an immense opportunity to maximize cooling-energy savings.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] A liquid desiccant-assisted free-cooling system for energy-efficient data centers in hot and humid climates
    Park, Hyo-Lim
    Lee, Soo-Jin
    Lee, Jae-Hee
    Jeong, Jae-Weon
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 52
  • [2] Reducing the Demand of Energy Cooling in the CED, "Centers of Processing Data", with Use of Free-Cooling Systems
    Cannistraro, G.
    Cannistraro, M.
    Cannistraro, A.
    Galvagno, A.
    Trovato, G.
    INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2016, 34 (03) : 498 - 502
  • [3] Worldwide Energy Analysis of Major Free Cooling Methods for Data Centers
    Gozcu, Ozan
    Ozada, Berk
    Carfi, Muhammed Ugur
    Erden, Hamza Salih
    PROCEEDINGS OF THE 2017 SIXTEENTH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS ITHERM 2017, 2017, : 968 - 976
  • [4] Meteorological Assessment and Implementation of an Air-Side Free-Cooling System for Data Centers in Chile
    Diaz, Andres J.
    Neves, Gisella
    Silva-Llanca, Luis
    del Valle, Marcelo
    Cardemil, Jose M.
    PROCEEDINGS OF THE 2017 SIXTEENTH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS ITHERM 2017, 2017, : 943 - 947
  • [5] Free-cooling thermal energy storage using phase change materials in an evaporative cooling system
    Walsh, Brendan P.
    Murray, Sean N.
    O'Sullivan, D. T. J.
    APPLIED THERMAL ENGINEERING, 2013, 59 (1-2) : 618 - 626
  • [6] Cooling performance of a pump-driven two phase cooling system for free cooling in data centers
    Ma, Yuezheng
    Ma, Guoyuan
    Zhang, Shuang
    Zhou, Feng
    APPLIED THERMAL ENGINEERING, 2016, 95 : 143 - 149
  • [7] Improving energy and water consumption of a data center via air free-cooling economization: The effect weather on its performance
    Silva-Llanca, Luis
    Ponce, Carolina
    Bermudez, Elizabeth
    Martinez, Diego
    Diaz, Andres J.
    Aguirre, Fabian
    ENERGY CONVERSION AND MANAGEMENT, 2023, 292
  • [8] Analysis of energy saving potential of air-side free cooling for data centers in worldwide climate zones
    Lee, Kuei-Peng
    Chen, Hsiang-Lun
    ENERGY AND BUILDINGS, 2013, 64 : 103 - 112
  • [9] Modelling and control of a free cooling system for Data Centers
    Beghi, Alessandro
    Cecchinato, Luca
    Dalla Mana, Giuseppe
    Lionello, Michele
    Rampazzo, Mirco
    Sisti, Enrico
    BEYOND NZEB BUILDINGS, 2017, 140 : 447 - 457
  • [10] Experimental study on free cooling performance of an integrated cooling system based on loop thermosyphon for data centers
    Wang, Jing
    Cao, Xiaoling
    Yuan, Yanping
    Yu, Nanyang
    Zhou, Xu
    Li, Jinwei
    Wu, Lang
    ENERGY, 2025, 322