Hyperangulated vs. Macintosh videolaryngoscopy in adults with anticipated difficult airway management: a randomised controlled trial

被引:10
|
作者
Koehl, Vera [1 ]
Wuensch, Viktor A. [1 ]
Mueller, Marie-Claire [1 ]
Sasu, Phillip B. [1 ]
Dohrmann, Thorsten [1 ]
Peters, Tanja [1 ]
Tolkmitt, Josephine [1 ]
Dankert, Andre [1 ]
Krause, Linda [2 ]
Zoellner, Christian [1 ]
Petzoldt, Martin [1 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Ctr Anaesthesiol & Intens Care Med, Dept Anaesthesiol, Hamburg, Germany
[2] Univ Med Ctr Hamburg Eppendorf, Inst Med Biometry & Epidemiol, Hamburg, Germany
关键词
airway management; intubation; intratracheal; laryngoscopes; laryngoscopy; respiratory system; UNIVERSAL VIDEOLARYNGOSCOPY; TRACHEAL INTUBATION; VALIDATION;
D O I
10.1111/anae.16326
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background It is not certain whether the blade geometry of videolaryngoscopes, either a hyperangulated or Macintosh shape, affects glottic view, success rate and/or tracheal intubation time in patients with expected difficult airways. We hypothesised that using a hyperangulated videolaryngoscope blade would visualise a higher percentage of glottic opening compared with a Macintosh videolaryngoscope blade in patients with expected difficult airways. Methods We conducted an open-label, patient-blinded, randomised controlled trial in adult patients scheduled to undergo elective ear, nose and throat or oral and maxillofacial surgery, who were anticipated to have a difficult airway. All airway operators were consultant anaesthetists. Patients were allocated randomly to tracheal intubation with either hyperangulated (C-MAC D-BLADE (TM)) or Macintosh videolaryngoscope blades (C-MAC (TM)). The primary outcome was the percentage of glottic opening. First attempt success was designated a key secondary outcome. Results We assessed 2540 adults scheduled for elective head and neck surgery for eligibility and included 182 patients with expected difficult airways undergoing orotracheal intubation. The percentage of glottic opening visualised, expressed as median (IQR [range]), was 89 (69-99 [0-100])% with hyperangulated videolaryngoscope blades and 54 (9-90 [0-100])% with Macintosh videolaryngoscope blades (p < 0.001). First-line hyperangulated videolaryngoscopy failed in one patient and Macintosh videolaryngoscopy in 12 patients (13%, p = 0.002). First attempt success rate was 97% with hyperangulated videolaryngoscope blades and 67% with Macintosh videolaryngoscope blades (p < 0.001). Conclusions Glottic view and first attempt success rate were superior with hyperangulated videolaryngoscope blades compared with Macintosh videolaryngoscope blades when used by experienced anaesthetists in patients with difficult airways.
引用
收藏
页码:957 / 966
页数:10
相关论文
共 50 条
  • [1] Videolaryngoscopy in the management of the difficult airway: a comparison with the Macintosh blade
    Stroumpoulis, Konstantinos
    Pagoulatou, Alexandra
    Violari, Magda
    Ikonomou, Irini
    Kalantzi, Nausika
    Kastrinaki, Kalliopi
    Xanthos, Theodoros
    Michaloliakou, Christina
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2009, 26 (03) : 218 - 222
  • [2] Videolaryngoscopy vs. Direct Laryngoscopy for Elective Airway Management in Paediatric Anaesthesia A prospective randomised controlled trial
    Klabusayova, Eva
    Klucka, Jozef
    Kosinova, Martina
    Toukalkova, Michaela
    Stoudek, Roman
    Kratochvil, Milan
    Marecek, Lukas
    Svoboda, Michal
    Jabandziev, Petr
    Urik, Milan
    Stourac, Petr
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2021, 38 (11) : 1187 - 1193
  • [3] First-attempt awake tracheal intubation success rate using a hyperangulated unchannelled videolaryngoscope vs. a channelled videolaryngoscope in patients with anticipated difficult airway: a randomised controlled trial
    Taboada, Manuel
    Fernandez, Jorge
    Estany-Gestal, Ana
    Vidal, Inma
    Dos Santos, Laura
    Novoa, Carmen
    Perez, Alejandra
    Segurola, Javier
    Franco, Edgar
    Regueira, Julia
    Miron, Paula
    Sotojove, Rosa
    Cortinas, Julio
    Carinena, Agustin
    Peiteado, Marcos
    Rodriguez, Alfonso
    Seoane-Pillado, Teresa
    ANAESTHESIA, 2024, 79 (11) : 1157 - 1164
  • [4] The McGrath® Series 5 videolaryngoscope vs the Macintosh laryngoscope: a randomised, controlled trial in patients with a simulated difficult airway
    Taylor, A. M.
    Peck, M.
    Launcelott, S.
    Hung, O. R.
    Law, J. A.
    MacQuarrie, K.
    McKeen, D.
    George, R. B.
    Ngan, J.
    ANAESTHESIA, 2013, 68 (02) : 142 - 147
  • [5] Hyperangulated vs. Macintosh videolaryngoscopes for efficacy of orotracheal intubation in adults: a pairwise meta-analysis of randomised clinical trials
    de Carvalho, C. C.
    ANAESTHESIA, 2022, 77 (10) : 1172 - 1174
  • [6] Hyperangulated versus Macintosh blades for intubation with videolaryngoscopy in ICU: the randomised multicentre INVIBLADE-ICU trial study protocol
    Taboada, Manuel
    Estany-Gestal, Ana
    Fernandez, Jorge
    Vazquez, Olalla
    Pajares, Azucena
    Ramasco, Fernando
    Martinez, Sara
    Vallejo, Irene
    Perez, Ana
    Rama-Maceiras, Pablo
    Bermudez, Maria
    Power, Mercedes
    Garcia-Alvarez, Raquel
    Fernandez-Villa, Inmaculada
    Aguilera, Jose Luis
    Carrio, Marta
    Cabadas, Rafael
    Rubin, Anxo
    Williams, Monica Mercedes
    Fernandez-Garcia, Raquel
    Becerra, Angel
    Gine, Marta
    Garcia, Francisco Javier
    Iglesias, Maria Cristina
    Santamarina, Rosaura Maria
    Del Valle, Sara
    Charco, Luisa Maria
    Alonso, Maria Concepcion
    Rodriguez, Ines Maria
    Varela, Marina
    Hermoso, Jose Ignacio
    Vives, Marc
    Cabaleiro, Teresa
    BMJ OPEN, 2024, 14 (09):
  • [7] A model to predict difficult airway alerts after videolaryngoscopy in adults with anticipated difficult airways - the VIDIAC score
    Kohse, E. K.
    Siebert, H. K.
    Sasu, P. B.
    Loock, K.
    Dohrmann, T.
    Breitfeld, P.
    Barclay-Steuart, A.
    Stark, M.
    Sehner, S.
    Zoellner, C.
    Petzoldt, M.
    ANAESTHESIA, 2022, 77 (10) : 1089 - 1096
  • [8] Learning tracheal intubation with a hyperangulated videolaryngoscopy blade: sub-analysis of a randomised controlled trial
    Ott, Sascha
    Mueller-Wirtz, Lukas M.
    Bustamante, Sergio
    Roessler, Julian
    Skubas, Nikolaos J.
    Shah, Karan
    Sessler, Daniel I.
    Turan, Alparslan
    Ruetzler, Kurt
    ANAESTHESIA, 2025, 80 (04) : 395 - 403
  • [9] Evaluation of three unchannelled videolaryngoscopes and the Macintosh laryngoscope in patients with a simulated difficult airway: a randomised, controlled trial
    Kleine-Brueggeney, M.
    Buttenberg, M.
    Greif, R.
    Nabecker, S.
    Theiler, L.
    ANAESTHESIA, 2017, 72 (03) : 370 - 378
  • [10] Videolaryngoscopy vs. flexible fibrescopy for tracheal intubation in patients with cervical spine immobilisation: a randomised controlled trial
    Choi, S.
    Yoo, H. K.
    Shin, K. W.
    Kim, Y. J.
    Yoon, H. K.
    Park, H. P.
    Oh, H.
    ANAESTHESIA, 2023, 78 (08) : 970 - 978