Performance analysis of four-stage thermoelectric cooler for focal plane infrared detectors

被引:0
|
作者
Sun, Yuetong [1 ,2 ]
Zhou, Lin [1 ]
Meng, Fankai [1 ]
Wang, Zhipeng [1 ]
机构
[1] Naval Univ Engn, Coll Power Engn, Wuhan 430033, Peoples R China
[2] Special Equipment Safety Supervis Inspection Inst, Suzhou Branch, Suzhou 215031, Peoples R China
关键词
Infrared detector; Multistage thermoelectric cooler; Evaluation index; Pareto optimal solution; Finite time thermodynamics; Pareto; OPTIMIZATION;
D O I
10.1016/j.ijrefrig.2024.06.011
中图分类号
O414.1 [热力学];
学科分类号
摘要
A cooler provides a low-temperature working environment for refrigerated infrared detection chips and is an indispensable component in infrared detectors that ensures their smooth operation. In this paper, a thermodynamic model of a heat-pipe-type four-stage thermoelectric cooler with a large temperature difference applied to a focal plane infrared detector is constructed. The heat leakage of the detector is calculated using the model. The performance indexes of the coordination performance coefficient and module utilization coefficient are used to unify the cooling capacity and economic performance of the device. The impression of the working current, heat pipe parameters, and cross-sectional area of the thermoelectric leg on the performance of cooler are analyzed. A Pareto optimal solution is obtained using an NSGA-II algorithm and TOPSIS decision. A low cooling temperature is obtained using a multistage thermoelectric cooler to achieve a large cooling temperature difference. When the working current is 5.65 A and the cross-sectional area is 4.5 mm 2 , the maximum cooling temperature difference reaches 110.6 degrees C, and the lowest cooling temperature reaches-83.6 degrees C. When the working temperature of the detector is-60 degrees C, the current and cross-sectional area corresponding to the optimal solution of cooling capacityCOP-power consumption are 1.51 A and 2.74 mm 2 , respectively.
引用
收藏
页码:290 / 302
页数:13
相关论文
共 50 条
  • [1] Performance of Four-stage Thermoelectric Cooler for Extended Wavelength InGaAs Detectors
    Mo De-feng
    Yang Li-yi
    Liu Da-fu
    Xu Qin-fei
    Li Tao
    Li Xue
    SELECTED PAPERS FROM CONFERENCES OF THE PHOTOELECTRONIC TECHNOLOGY COMMITTEE OF THE CHINESE SOCIETY OF ASTRONAUTICS 2014, PT II, 2015, 9522
  • [2] Vacuum Packaging of InGaAs Focal Plane Array with Four-stage Thermoelectric Cooler
    Mo De-feng
    Liu Da-fu
    Yang Li-yi
    Xu Qin-fei
    Li Xue
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2013: INFRARED IMAGING AND APPLICATIONS, 2013, 8907
  • [3] Thermoelectric infrared detectors with improved mechanical stability for the Composite Infrared Spectrometer (CIRS) far infrared focal plane
    Fettig, R
    Lakew, B
    Brasunas, J
    Crooke, J
    Hakun, C
    Orloff, J
    CRYOGENIC OPTICAL SYSTEMS AND INSTRUMENTS VIII, 1998, 3435 : 126 - 135
  • [4] Range performance modeling for staring focal plane array infrared detectors
    Dahlberg, AGM
    Holmgren, O
    Infrared Imaging Systems: Design, Analysis, Modeling, and Testing XVI, 2005, 5784 : 81 - 90
  • [5] Numerical simulation and performance analysis of a four-stage centrifugal pump
    Li, Wei
    Jiang, Xiaoping
    Pang, Qinglong
    Zhou, Ling
    Wang, Wei
    ADVANCES IN MECHANICAL ENGINEERING, 2016, 8 (10) : 1 - 8
  • [6] Uncooled infrared detectors and focal plane arrays
    Tidrow, MZ
    Clark, WW
    Tipton, W
    Hoffman, R
    Beck, W
    Tidrow, SC
    Robertson, DN
    Pollehn, H
    Udayakumar, KR
    Beratan, HR
    Soch, K
    Hanson, CM
    Wigdor, M
    DETECTORS, FOCAL PLANE ARRAYS, AND IMAGING DEVICES II, 1998, 3553 : 178 - 187
  • [7] HgCdTe infrared detectors and focal plane arrays
    Bajaj, J.
    Conference on Optoelectronic and Microelectronic Materials and Devices, Proceedings, COMMAD, 1998, : 23 - 31
  • [8] Numerical simulation of the performance of a four-stage fan
    Yin, Song
    Jin, Dong-Hai
    Zhu, Fang
    Gui, Xing-Min
    Hangkong Dongli Xuebao/Journal of Aerospace Power, 2010, 25 (06): : 1366 - 1373
  • [9] Numerical study on infrared detectors cooling by multi-stage thermoelectric cooler combined with microchannel heat sink
    Zhou, Lin
    Meng, Fankai
    Sun, Yuetong
    APPLIED THERMAL ENGINEERING, 2024, 236
  • [10] Four-Stage Soft Startup of LLC Resonant Converter Based on State Plane Analysis
    Li, Jiahao
    Chen, Jie
    Hou, Junfeng
    Jiang, Lingfeng
    She, Yan
    Wang, Yong
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2024, 44 (16): : 6597 - 6609