Using Virtual Reality to teach ultrasound-guided needling skills for regional anaesthesia: A randomised controlled trial

被引:4
|
作者
Chuan, Alwin [1 ,2 ]
Bogdanovych, Anton [3 ]
Moran, Benjamin [4 ]
Chowdhury, Supriya [1 ,2 ]
Lim, Yean Chin [5 ]
Tran, Minh T. [1 ,2 ]
Lee, Tsz Yui [1 ]
Duong, Jayden [1 ]
Qian, Jennifer [1 ]
Bui, Tung [2 ]
Chua, Alex M. H. [2 ]
Jeyaratnam, Bahaven [2 ]
Siu, Steven [2 ]
Tiong, Clement [2 ]
McKendrick, Mel [6 ]
Mcleod, Graeme A. [7 ]
机构
[1] Univ New South Wales, Fac Med & Hlth, South Western Sydney Clin Sch, Sydney, Australia
[2] Liverpool Hosp, Dept Anaesthesia, Sydney, Australia
[3] Western Sydney Univ, MARCS Inst Brain Behav & Dev, Sydney, Australia
[4] Gosford Hosp, Dept Anaesthesia, Gosford, Australia
[5] Changi Gen Hosp, Dept Anaesthesia & Surg Intens Care, Singapore, Singapore
[6] Hariot Watt Univ, Sch Social Sci, Edinburgh, Scotland
[7] Univ Dundee, Sch Med, Dundee, Scotland
关键词
Virtual reality; Medical education; Regional anaesthesia; Ultrasound; Ultrasonography; SIMULATION; PERFORMANCE;
D O I
10.1016/j.jclinane.2024.111535
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Study objective: We previously designed and validated a virtual reality-based simulator to help train novices in ultrasound-guided needling skills necessary for safe and competent ultrasound-guided regional anaesthesia. This study was designed to compare the performance and error rates of novices trained by a human faculty aided with the assistance of this virtual reality simulator (virtual reality-assisted training), versus novices trained wholly by humans (conventional training). Design, setting, and participants: In this single centre, randomised controlled study, we used a standardised teaching protocol, rigorous blinding, iterative training of assessors, and validated global rating scale and composite error score checklists to assess skills learning of novice participants. Main results: We recruited 45 novices and scored 270 assessments of performance and error rates. Inter-rater correlation coefficient of reliability of scoring between assessors for the global rating scale was 0.84 (95%CI 0.68-0.92) and for the composite error score checklist was 0.87 (95%CI 0.73-0.93). After adjustment for age, sex, Depression, Anxiety and Stress-21, and baseline score, there was no statistical difference for virtual realityassisted training compared to conventional training in final global rating score (average treatment effect -3.30 (95%CI-13.07-6.48), p = 0.51) or in the final composite error score (average treatment effect 1.14 (95%CI -0.60-2.88), p = 0.20). Realism in the virtual reality simulator was similar to real-life when measured by the Presence Questionnaire, all components p > 0.79; and task workload assessed by the NASA-Task Load Index was not statistically different between groups, average treatment effect 5.02 (95%CI -3.51-13.54), p = 0.25. Results were achieved in the virtual reality-assisted group with half the human faculty involvement. Conclusion: Novices trained using a hybrid, virtual reality-assisted teaching program showed no superiority to novices trained using a conventional teaching program, but with less burden on teaching resources.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Using psychometric ability to improve education in ultrasound-guided regional anaesthesia: a multicentre randomised controlled trial
    Chuan, A.
    Jeyaratnam, B.
    Iohom, G.
    Shorten, G.
    Lee, P.
    Miglani, S.
    Kwofie, K.
    Szerb, J.
    Niazi, A. U.
    Jin, R.
    Jen, T.
    McCartney, C. J.
    Ramlogan, R.
    ANAESTHESIA, 2021, 76 (07) : 911 - 917
  • [2] Design and validation of a virtual reality trainer for ultrasound-guided regional anaesthesia
    Chuan, A.
    Qian, J.
    Bogdanovych, A.
    Kumar, A.
    McKendrick, M.
    McLeod, G.
    ANAESTHESIA, 2023, 78 (06) : 739 - 746
  • [3] Ultrasound-guided regional anaesthesia
    Carty, Suzanne
    Nicholls, Barry
    BJA EDUCATION, 2007, 7 (01) : 20 - 24
  • [4] A randomised controlled trial comparing meat-based with human cadaveric models for teaching ultrasound-guided regional anaesthesia
    Chuan, A.
    Lim, Y. C.
    Aneja, H.
    Duce, N. A.
    Appleyard, R.
    Forrest, K.
    Royse, C. F.
    ANAESTHESIA, 2016, 71 (08) : 921 - 929
  • [5] Learning in ultrasound-guided regional anaesthesia
    Desai, N.
    Hetreed, M.
    ANAESTHESIA, 2017, 72 : 77 - 77
  • [6] Effect of mental rotation skills training on ultrasound-guided regional anaesthesia task performance by novice operators: a rater -blinded, randomised, controlled study
    Hewson, David W.
    Knudsen, Rasmus
    Shanmuganathan, Sanjeevan
    Ferguson, Eamonn
    Hardman, Jonathan G.
    Bedforth, Nigel M.
    McCahon, Rob A.
    BRITISH JOURNAL OF ANAESTHESIA, 2020, 125 (02) : 168 - 174
  • [7] Augmented reality in ultrasound-guided regional anaesthesia: useful tool or expensive toy?
    Marhofer, Peter
    Eichenberger, Urs
    BRITISH JOURNAL OF ANAESTHESIA, 2023, 131 (03) : 442 - 445
  • [8] Lighting during ultrasound-guided regional anaesthesia
    Soltanifar, S.
    Rashid, A. K.
    Crowley, M. P.
    ANAESTHESIA, 2010, 65 (11) : 1148 - 1148
  • [9] Practical aspects of ultrasound-guided regional anaesthesia
    Raju, Pavan Kumar B. C.
    Grant, Calum R. K.
    ANAESTHESIA AND INTENSIVE CARE MEDICINE, 2013, 14 (04): : 137 - 141
  • [10] Practical aspects of ultrasound-guided regional anaesthesia
    Raju, Pavan Kumar B. C.
    Grant, Calum R. K.
    ANAESTHESIA AND INTENSIVE CARE MEDICINE, 2019, 20 (04): : 205 - 209